Molecular Sieve Air Prepurification
Layered alumina and 13X beds that take water and carbon dioxide out of air before the cold box.
Quick Answer
Air prepurification removes water and carbon dioxide from compressed air before it enters the cold box of a cryogenic air separation unit, where both would freeze and block the exchanger. A layered bed of activated alumina and 13X molecular sieve takes both out. The bed is regenerated by heat or by a pressure swing.
- Molecular sieve 13X APG
- Beads and APG-P pellets
- Activated alumina inlet layer
- Crush strength by ASTM D4179
- Manufactured by Medaad
Updated
Protecting a Cryogenic Cold Box
An air separation unit chills air until its components liquefy and separate by boiling point. Anything in that air with a higher freezing point than the process temperature turns solid on the way down.
Water and carbon dioxide both do. They cause no harm in the compressor. In the cold box they freeze and block the exchanger passages, and the unit comes off line to be thawed.
Figure 01 · Freezing points are physical constants. The cold box band is typical of cryogenic air separation in general.
Water and CO₂ Limits at the Cold Box Inlet
A compressed air dryer is judged on a water dew point some tens of degrees below zero. It does not remove carbon dioxide.
A prepurification unit must remove carbon dioxide too. It also has to take water and carbon dioxide to limits far below anything a plant air dryer works to.
| Contaminant | Turns solid at | If it reaches the cold box |
|---|---|---|
| Water | 0 °C | Ice in the exchanger passages, flow falls away |
| Carbon dioxide | about minus 78 °C | Solid carbon dioxide builds slowly and blocks the same passages |
| Heavy hydrocarbons | varies | Accumulate in the oxygen rich sump, which is a safety concern |
Layered Alumina and 13X Bed
The bed is normally two layers. Activated alumina sits at the inlet and removes most of the water. It does this at a lower regeneration cost than a zeolite would.
A 13X layer follows. It takes the carbon dioxide and any water left after the alumina. Both layers are made by Medaad, the group manufacturer.
13X APG Air Plant Grade
The usual charge is 13X APG, an air plant grade of 13X. Its binder and particle specification suit front end service. It comes as beads and as 13X APG-P pellets.
TSA and PSA Front Ends
Front end units run either way. A TSA unit heats the bed. It uses less purge gas, but needs a heater and a longer cycle. A PSA unit regenerates on pressure alone. Its cycle is shorter and it uses more of the plant's air as purge.
The adsorbent is specified differently for each. A PSA unit switches far more often, so the bead needs more mechanical strength.
| Front end type | Thermal swing | Pressure swing |
|---|---|---|
| Regeneration | heated purge | pressure only |
| Cycle length | hours | minutes |
| Purge air used | lower | higher |
| Demand on the bead | thermal | mechanical, from frequent switching |
Derime Downtime and Bed Margin
When a front end bed loses capacity, the cost is downtime. Carbon dioxide that passes the bed builds up in the cold box over days or weeks until flow drops. The fix is a derime. The box is warmed, the solids are driven off, and the box is cooled again.
Lost production is costly, so front end beds are sized with more margin than most other duties.
Front End Packages and Recharges
New front ends are supplied as the cryogenic ASU prepurification package, with both layers loaded. For units in service, the alumina and 13X layers are supplied as a recharge sized to the existing vessel.
Related Air Separation Duties
Oxygen made by adsorption, with no cold box, is covered under oxygen generation. Carbon dioxide polishing ahead of a cryogenic gas plant is CO₂ removal. Layer depths and vessel sizing follow bed design.
Air Prepurification Questions
Is there a 13X grade with more carbon dioxide capacity?
Yes. A variant with higher carbon dioxide capacity is made for heavily loaded inlet air, or for a bed that must run longer between switches.
What data is needed to quote a prepurifier recharge?
Give the vessel size, the switching arrangement and when carbon dioxide first showed downstream. For a new bed, add the air rate, the pressure and the cold box inlet limit.
Can the group supply the whole front end unit?
Yes. PuraSpecs, part of the group, designs and fabricates prepurification packages for cryogenic air separation.
How hot can a 13X layer be heated during regeneration?
The crystal degrades if the bed is held above about 325 °C, so the heating step stays below that limit. The heat and the cycle are worked out as described in regeneration temperature and cycle.
Can the 13X be shipped under nitrogen?
Yes. A nitrogen blanket is a published pack option for hygroscopic grades. It keeps the sieve from taking up moisture from the air before it is loaded.
Quote for a Prepurification Charge
A front end charge is sized from the air rate and the cold box inlet limit. Add the vessel dimensions if the front end is already built.
Request the TDS and SDS
Name the grade, 13X APG beads or APG-P pellets, and the documents you need.