Adsorption Systems and Turnkey Packages, Seen From the Adsorbent
Dryers, vessels and complete group packages, described from the side of the adsorbent they carry.
Quick Answer
Molecular sieve adsorption systems are the engineered units that carry a zeolite charge. A dehydration system holds the adsorbent in two or more pressure vessels that take turns. One bed dries the gas on 4A or 13X while another is heated with dry purge gas, typically at 200 to 315 °C, then cooled and returned to service.
- Zeolite 3A, 4A, 5A and 13X
- Media made by Medaad
- Units by PuraSpecs
- EPC by FireBag
- Crush strength to ASTM D4179
A dehydration system is the plant that carries the adsorbent. It has pressure vessels, switching valves, a regeneration heater, a cooler and controls. SorbiTech describes these systems from the side of the media. The grade, the charge size and the regeneration duty set much of what the equipment must do.
A performance basis for a real unit is written from stated feed conditions: flow, pressure, temperature, contaminants and the outlet water content required.
Typical duties for these units are natural gas dehydration and LNG pretreatment, most often on 4A or 13X.
Units, Vessels and Published Group Packages
Three subjects sit under systems. The dehydration unit is the whole process loop around the beds. The adsorber vessel is the pressure shell with the internals that hold the charge in place. The group packages are complete systems published by SorbiTech Group, each built around an adsorbent duty.
Dehydration Units
Most continuous dryers run two beds on a thermal swing. One bed dries the feed while the other is heated with regeneration gas. That bed is then cooled and switched back into service. The guide to dehydration units follows this cycle and the equipment it needs. It also sets out which items usually sit with the media supplier, the unit builder and the client. Most designs stay below about 325 °C. A gas plant dryer ahead of a cryogenic section is commonly designed for below 0.1 ppmv water.
Adsorber Vessels
The vessel holds the charge and spreads the flow evenly across it. Its internals are the inlet distributor, support grid and balls, hold down layer, manways and loading ports. The adsorber vessel guide explains what each item does for the sieve. Flow direction, velocity limits and insulation are covered there as guidance.
Published Group Packages
SorbiTech Group publishes complete packages on its corporate site. The twin tower TSA dehydration unit and the heatless desiccant air dryer are drying systems. The air separation prepurification package removes water and carbon dioxide ahead of a cold box. The hydrogen PSA purification package and the oxygen VPSA package separate gases by pressure swing. The gas sweetening unit removes acid gas, often upstream of a dryer.
How Scope Splits Across the Group
Medaad makes the media, and SorbiTech sets the grade, the charge and the regeneration duty. PuraSpecs builds the engineered gas and liquid treatment packages around the beds, and FireBag handles EPC and field execution on site.
An order can cover the media alone, a complete unit or a delivered project. The quotation lists the scope item by item. Foundations, utilities and upstream separation are usually client scope.
The blue box is the media and bed design, the subject of molecularsieve.com; the light boxes are carried by the group siblings.
Related Pages for System Buyers
Charge change out on an existing unit is set out in loading and replacement. The front end of an air separation plant is covered under air prepurification, and gas plant units in context under oil and gas processing.
Questions on Adsorption Systems
What is the difference between a thermal swing and a pressure swing unit?
A thermal swing unit regenerates a bed with heated purge gas, and suits drying. A pressure swing unit regenerates by dropping the pressure, with no heater, and suits bulk separations such as hydrogen purification and oxygen generation.
Can SorbiTech supply only the media for a unit built by another company?
Yes. The grade, bead size, layer heights and ball sizes are then checked against the vessel drawing and the original bed design, because a wrong size shows up later as pressure drop or lost beads.
Why does an oxygen VPSA charge need strong beads?
Its cycles are short, often under a minute, so a charge may see hundreds of thousands of switches in a year. Its life depends on mechanical strength.
What dew point does a heatless desiccant air dryer reach?
A heatless desiccant dryer commonly reaches a pressure dew point of minus 40 °C. A 4A molecular sieve charge is used where the target is deeper still.
Why is a gas sweetening unit placed ahead of a dryer?
The amine unit takes out the bulk of the hydrogen sulfide and carbon dioxide. The dryer then handles the water, and sulfur traces left after the amine can go to a 13X polishing bed.
Starting a System Enquiry
A useful enquiry names the fluid, the flow, the pressure and temperature, and the water content in and out. Say whether the request covers the media only, a complete unit, or delivery on site. Add any existing vessel data, the regeneration gas available and the cycle in use.