Molecular SieveZeolite AdsorbentsBy SorbiTech™
Molecular sieve 13X pellets and beads

13X Molecular Sieve

13X Molecular Sieve for Air Purification and Sulfur Removal

Zeolite 13X molecular sieve pellets and beads

SorbiTech Group 13X molecular sieve is a Type X zeolite with a pore of about 10 Å, the widest in the range. It adsorbs water, carbon dioxide, hydrogen sulfide, mercaptans and ammonia. In oxygen PSA it also holds nitrogen back and lets oxygen pass.

The open pore lets one 13X charge clear several contaminants in a single pass. Water, carbon dioxide and sulfur compounds load into the same bed, and its large cages give it a high capacity for them. That is why 13X is the usual charge where a stream has to lose more than its water.

Available Mesh Sizes

Mesh SizeParticle DiameterShapes
8 x 12 mesh1.6 to 2.6 mmBeads (spheres)
Pellets (extrudates)
4 x 8 mesh2.5 to 5.0 mm
1/16 inch1.5 to 1.8 mm
1/8 inch3.1 to 3.4 mm

What the Wide 13X Pore Takes In

The Type X framework is more open than Type A, with larger cages. The 13 in the name is a product name, not a pore size. Sulfur compounds come in many sizes, and a bed needs an opening wide enough for the largest one in the feed. At about 10 Å, 13X admits methyl mercaptan and the heavier mercaptans as well as hydrogen sulfide.

Figure 01 · What clears a 10 Å window
Molecule sizes against the 10 angstrom window of the Type X framework The window is drawn at 10 angstrom. Water at 2.6, ammonia at 2.6, carbon dioxide at 3.3, hydrogen sulfide at 3.6, methyl mercaptan at about 4.5 and the heavier mercaptans at about 5.5 angstrom are all narrower than the window and enter the supercage. THE WINDOW, DRAWN TO SCALE 10 Å supercage entry WHAT PASSES THROUGH IT Water 2.6 Å Ammonia 2.6 Å Carbon dioxide 3.3 Å Hydrogen sulfide 3.6 Å Methyl mercaptan about 4.5 Å Heavier mercaptans about 5.5 Å all clear the window

The circles and the window are drawn to the same scale. The largest sulfur molecule shown fills about half the opening, so one bed takes the whole mercaptan range.

13X Ahead of a Cold Box

Air entering a cryogenic plant carries water and carbon dioxide. Neither harms the compressor. In the cold box both freeze, block the exchanger passages and force the unit off line to be thawed. A front end bed removes them first. Many front ends place activated alumina at the air inlet with a 13X layer after it. The 13X takes the carbon dioxide and any water that reaches it. Carbon dioxide that slips past builds up in the cold box over days or weeks, so these beds are sized with extra margin.

Sweetening Gas and LPG with 13X

An amine unit removes most of the hydrogen sulfide and carbon dioxide from a gas, but most of the mercaptans pass it. A 13X bed downstream polishes out the last of the sulfur. On LPG the sulfur and the water load into the sieve, and the propane and butane flow on as product. In regeneration a sulfur bed first holds at 180 to 200 °C for one to two hours. This sweeps the mercaptans out before the bed reaches the heat that breaks them down.

Cooling the Bed After Regeneration

When the hot step ends, the heater is bypassed and the purge keeps flowing to carry heat out of the 13X. The bed outlet temperature is watched through this step. The tower returns to service only once the outlet has cooled close to the feed temperature. 13X loads carbon dioxide and sulfur well only when it is cool. A tower switched in too warm lets them slip at the start of the step, and on an air front end that slip goes straight to the cold box.

Why Choose SorbiTech Group

Quality Assurance

Worldwide Supply

In Stock, Fast Delivery

Technical Support

Supply and Engineering Support for 13X

SorbiTech Group supplies 13X molecular sieve to air separation plants, gas processors removing carbon dioxide and sulfur, LPG treaters and oxygen generator makers. We fill new front ends and treaters, and we recharge beds that are due for a change out.

Our application engineers select the grade, particle size and bed arrangement from your data. They work from the feed composition, with the carbon dioxide and every sulfur species in it, and from the flow, pressure, temperature, outlet specification and cycle. For larger scopes, the group also designs and supplies the adsorber vessels and complete treating units.

Share your operating data with us for a 13X proposal on your bed.

Applications

13X Molecular Sieve in Air, Sulfur and Oxygen Service

01
Carbon dioxide and moisture removal from natural gas
One bed takes both out, so the gas is ready for the pipeline or the cryogenic section.
View carbon dioxide and moisture removal from natural gas

FAQ

Common Questions on 13X Beds

Your question is not listed? Ask our engineers about 13X.

Can 13X be used for drying alone?

Yes. 13X is a strong desiccant and holds water to very low levels. It is often chosen for drying when carbon dioxide or sulfur compounds have to leave the stream in the same bed.

What purge temperature does 13X need?

In gas dehydration practice, 13X is typically regenerated at about 280 to 315 °C, hot enough for sulfur compounds and carbon dioxide to leave fully. The exact value depends on the dew point target and the pressure.

How far down does 13X take hydrogen sulfide and mercaptans?

To single figure parts per million where the feed and the cycle are designed for it. Inlet levels swing with the upstream unit, so outlet values are typical, not fixed.

What leaves a 13X bed when it is regenerated?

On a sulfur duty, heating releases a small, concentrated stream of hydrogen sulfide and mercaptans. It is cooled and routed to sulfur recovery or back to the amine system, so it is not vented.

Why does a 13X bed warm up on a liquid feed?

Taking up water and sulfur from a dense liquid releases heat fast, and the bed temperature climbs. The feed rate is controlled and the vessel is sized to spread the heat.

How long does a 13X change out take?

It depends on the vessel size, the access, the sulfur or hydrocarbon load on the spent sieve and the pack format. Purging and cooling before the vessel is opened often take longer than the unloading itself.

Contact