Molecular Sieve Helium Recovery Pretreatment
A layered 13X and 4A guard bed that keeps water and carbon dioxide out of a helium cold box.
Quick Answer
Helium recovery pretreatment uses a molecular sieve guard bed to take water, carbon dioxide and heavy hydrocarbons out of crude helium feed just before the cryogenic cold box. Any trace left in the gas would freeze there. A layered bed of 13X and 4A holds each contaminant to trace levels and is regenerated with heat.
- Molecular sieve 13X and 4A
- Alumina or silica gel bulk layer
- Lead and lag guard beds
- Crush strength by ASTM D4179
- Manufactured by Medaad
Updated
Cleaning Up Crude Helium
Some natural gas fields hold helium at a few percent or less. It is recovered in a cryogenic cold box that cools the gas until everything except helium liquefies. The cold box runs near minus 190 °C. Any water, carbon dioxide or heavy hydrocarbon left in the feed freezes in its narrow aluminium passages.
A molecular sieve guard bed just before the cold box takes these down to trace levels. It adsorbs the contaminants, lets the gas pass, and is regenerated with heat. Most of the acid gas and water is removed further upstream by an amine unit and a glycol unit.
Helium is usually a side stream of a larger plant, most often a nitrogen rejection unit or an LNG train, since both cool the gas deeply. The guard outlet is set by the coldest exchanger in that process.
Lead and Lag Guard Beds
The guard is usually run lead and lag. Two beds sit in series. The lead bed does the work and the lag bed sits behind it. When the lead bed saturates, the lag bed catches the breakthrough before it reaches the cold box.
The cold box does the separation. The sieve guards it.
Helium Purification Before the Cold Box
The guard holds each contaminant below the level at which it freezes in the cold box. These are among the tightest cleanup figures in gas processing. The inlet depends on the upstream treating, so the values are typical.
| Contaminant | Why it must go | Guard outlet |
|---|---|---|
| Water | Freezes as ice in the aluminium passages | below 0.1 ppmv |
| Carbon dioxide | Freezes as solid CO₂ and blocks the passages | below 1 ppmv |
| Heavy hydrocarbons | Freeze and wax at cold box temperature | below 1 ppmv |
Guard targets are set by the cold box designer. Confirm them against the process specification.
Layered Guard Bed and Thaw Downtime
A trace of water or carbon dioxide past the guard freezes in the exchanger passages and plugs them. The plant must then be stopped, warmed and thawed, which takes days.
The guard bed is layered. Activated alumina or silica gel, both from Medaad, takes the bulk water. A 13X layer takes the carbon dioxide and heavy ends. A 4A layer polishes the last of the water. The bed rests on inert ceramic balls. Bed design sets the layers and the depth.
Contaminant that passes the guard freezes in the cold box.
Guard Units, Depth and Margin
Bed depth and margin are the main sizing choices. Extra volume usually costs less than a thaw. The guard vessels are laid out like the twin tower TSA dehydration unit, and adsorber vessel design covers the vessel itself. If an installed bed has started to pass contaminant, check the cause before it is recharged.
Where Helium Is Recovered
Helium is taken from gas handled in oil and gas processing and from the trains described under LNG liquefaction plants. The finished gas is sold through air separation and industrial gases.
Beds Around Helium Recovery
Helium Guard Bed Questions
Does the molecular sieve separate the helium?
No. The cryogenic step separates the helium, followed by membranes or pressure swing units. The sieve guards the cold box.
How is a helium guard bed regenerated?
On a thermal swing, with the lead and lag beds swapping duty. A heated slipstream of dry gas, 200 to 315 °C at the inlet, drives off the water, carbon dioxide and heavy ends, and a cooling pass follows. Each regeneration must be complete, because a partly regenerated bed breaks through early.
What is water roll up on a guard bed?
Water pushes carbon dioxide off the bed, and the carbon dioxide breaks through before the end of the cycle. Enough water capacity in the bed and a properly sized upstream dryer prevent it.
Can heavy hydrocarbons damage the 13X layer?
Yes. Heavy ends held on the 13X can crack during hot regeneration and cost capacity. The heavy layer is sized for the feed, and the regeneration temperature is held in band.
Why does the guard need an outlet dust filter?
Bed settling and cycling can powder weak beads and raise the pressure drop. A hard bead, careful loading and an outlet dust filter keep fines out of the cold box.
Quote for a Helium Recovery Guard Bed
A guard bed sized to hold water, carbon dioxide and heavy ends below their freezing levels in the cold box.
Request the TDS and SDS
Name the grades, 13X, 4A or both, and the documents you need for the guard bed.