Molecular SieveZeolite AdsorbentsBy SorbiTech™
Blue adsorber towers at a gas processing plant

Molecular Sieve Helium Recovery Pretreatment

A layered 13X and 4A guard bed that keeps water and carbon dioxide out of a helium cold box.

Find My Solution

Quick Answer

Helium recovery pretreatment uses a molecular sieve guard bed to take water, carbon dioxide and heavy hydrocarbons out of crude helium feed just before the cryogenic cold box. Any trace left in the gas would freeze there. A layered bed of 13X and 4A holds each contaminant to trace levels and is regenerated with heat.

  • Molecular sieve 13X and 4A
  • Alumina or silica gel bulk layer
  • Lead and lag guard beds
  • Crush strength by ASTM D4179
  • Manufactured by Medaad

Request the TDS Request the SDS

Updated

Cleaning Up Crude Helium

Some natural gas fields hold helium at a few percent or less. It is recovered in a cryogenic cold box that cools the gas until everything except helium liquefies. The cold box runs near minus 190 °C. Any water, carbon dioxide or heavy hydrocarbon left in the feed freezes in its narrow aluminium passages.

A molecular sieve guard bed just before the cold box takes these down to trace levels. It adsorbs the contaminants, lets the gas pass, and is regenerated with heat. Most of the acid gas and water is removed further upstream by an amine unit and a glycol unit.

Helium is usually a side stream of a larger plant, most often a nitrogen rejection unit or an LNG train, since both cool the gas deeply. The guard outlet is set by the coldest exchanger in that process.

Lead and Lag Guard Beds

The guard is usually run lead and lag. Two beds sit in series. The lead bed does the work and the lag bed sits behind it. When the lead bed saturates, the lag bed catches the breakthrough before it reaches the cold box.

Figure 01 · The guard bed in front of the cold box
The molecular sieve guard bed ahead of the cryogenic helium separation The feed passes an amine unit for carbon dioxide, a dehydration unit for the bulk water, a molecular sieve guard bed that takes the last water, carbon dioxide and heavy ends to trace levels, and then the cryogenic cold box that separates the helium. AMINE bulk CO₂ DEHYDRATION bulk water SIEVE GUARD trace water, CO₂, heavies COLD BOX separates the helium

The cold box does the separation. The sieve guards it.

Helium Purification Before the Cold Box

The guard holds each contaminant below the level at which it freezes in the cold box. These are among the tightest cleanup figures in gas processing. The inlet depends on the upstream treating, so the values are typical.

ContaminantWhy it must go Guard outlet
Water Freezes as ice in the aluminium passages below 0.1 ppmv
Carbon dioxide Freezes as solid CO₂ and blocks the passages below 1 ppmv
Heavy hydrocarbons Freeze and wax at cold box temperature below 1 ppmv

Guard targets are set by the cold box designer. Confirm them against the process specification.

Layered Guard Bed and Thaw Downtime

A trace of water or carbon dioxide past the guard freezes in the exchanger passages and plugs them. The plant must then be stopped, warmed and thawed, which takes days.

The guard bed is layered. Activated alumina or silica gel, both from Medaad, takes the bulk water. A 13X layer takes the carbon dioxide and heavy ends. A 4A layer polishes the last of the water. The bed rests on inert ceramic balls. Bed design sets the layers and the depth.

Figure 02 · Why the guard cannot break through
A clean cold box passage against one blocked by frozen contaminant A clean aluminium passage lets the gas flow. A passage where trace water or carbon dioxide got past the guard is blocked by ice, which stops the flow and shuts the plant down for a long thaw. GUARD HOLDING gas flows, plant runs TRACE BREAKTHROUGH ice blocked, days of thaw vs

Contaminant that passes the guard freezes in the cold box.

Guard Units, Depth and Margin

Bed depth and margin are the main sizing choices. Extra volume usually costs less than a thaw. The guard vessels are laid out like the twin tower TSA dehydration unit, and adsorber vessel design covers the vessel itself. If an installed bed has started to pass contaminant, check the cause before it is recharged.

Request a Quote

Where Helium Is Recovered

Helium is taken from gas handled in oil and gas processing and from the trains described under LNG liquefaction plants. The finished gas is sold through air separation and industrial gases.

Related duties

Beds Around Helium Recovery

01
LNG pretreatment
The same cryogenic cleanup, water below 0.1 ppmv plus mercaptans and heavy ends, before liquefaction.
View LNG pretreatment

Helium Guard Bed Questions

Does the molecular sieve separate the helium?

No. The cryogenic step separates the helium, followed by membranes or pressure swing units. The sieve guards the cold box.

How is a helium guard bed regenerated?

On a thermal swing, with the lead and lag beds swapping duty. A heated slipstream of dry gas, 200 to 315 °C at the inlet, drives off the water, carbon dioxide and heavy ends, and a cooling pass follows. Each regeneration must be complete, because a partly regenerated bed breaks through early.

What is water roll up on a guard bed?

Water pushes carbon dioxide off the bed, and the carbon dioxide breaks through before the end of the cycle. Enough water capacity in the bed and a properly sized upstream dryer prevent it.

Can heavy hydrocarbons damage the 13X layer?

Yes. Heavy ends held on the 13X can crack during hot regeneration and cost capacity. The heavy layer is sized for the feed, and the regeneration temperature is held in band.

Why does the guard need an outlet dust filter?

Bed settling and cycling can powder weak beads and raise the pressure drop. A hard bead, careful loading and an outlet dust filter keep fines out of the cold box.

Quote for a Helium Recovery Guard Bed

A guard bed sized to hold water, carbon dioxide and heavy ends below their freezing levels in the cold box.

Request a Quote
Contact
Email[email protected] Call+971 56 777 3027