Molecular Sieve Cracked Gas and Olefin Drying
3A molecular sieve dries cracker gas, ethylene and propylene while the olefin stays outside the pore.
Quick Answer
Cracked gas and olefin drying removes water from ethylene, propylene and cracker gas on 3A molecular sieve. Water at 2.6 Å enters the 3 Å window while ethylene at 3.9 Å stays out, so no monomer is left on the hot bed to form green oil and the cold train stays free of ice.
- 3A molecular sieve
- Beads and pellets
- 8 x 12 and 4 x 8 mesh
- Crush strength by ASTM D4179
- Tapped density by ASTM D4164
- Manufactured by Medaad
Updated
Drying Gas From a Cracker
Gas leaving a steam cracker has been quenched with water, so it arrives saturated. Everything after that point runs cold: the chilling train, the demethaniser and the refrigeration circuits that separate the products.
At those temperatures water turns to ice and blocks the cold train. The dryer sits ahead of the cold section to take the water out first.
Why Olefin Dryers Use 3A
Ethylene and propylene are small enough to enter a 4A window. The 3 Å grade is specified to keep them out.
An olefin held inside a zeolite cage sits against acid sites on the framework. There it reacts with the next olefin molecule to arrive, and the bed starts to foul.
Figure 01 · The sequence is the accepted explanation for capacity loss on unsaturated streams. How fast it runs depends on the temperature and the acid sites available.
| In the stream | Molecule | Into a 3 A pore |
|---|---|---|
| Water | 2.6 angstrom | yes, the duty |
| Ethylene | 3.9 angstrom | no |
| Propylene | 4.5 angstrom | no |
| Butadiene | 5.2 angstrom | no |
Green Oil and Coking
Two olefins joined inside the pore make a heavier molecule that is too large to leave. More joins build it into green oil, which coats the bead from the inside.
Heating the bed to regenerate it does not drive that oil off. It bakes into coke. The lost capacity does not return, and the charge has to be replaced well before the beads wear out.
Regeneration Temperature for Olefin Beds
An olefin dryer is regenerated more gently than a natural gas bed. Water needs heat to come off. Any olefin left in the bed reacts faster as it gets hotter.
Usual practice is a lower temperature held for longer, with the olefin swept out of the vessel before heating starts. The table shows the usual shape of that cycle. Each train sets its own values.
| Parameter | Usual practice | Reason |
|---|---|---|
| Regeneration | cooler than a gas bed | the olefin reacts when hot |
| Hold time | longer | makes up for the lower heat |
| Sweep | before heating | clears olefin from the vessel |
| Working charge | 3A | keeps the olefin out |
Grade and Form for Each Cracker Dryer
A cracker usually has more than one dryer. One bed dries the charge gas after compression. Polishing beds dry the separated ethylene and propylene before storage or a polymer unit. PuraDry 3A, the 3A grade, goes into every position. The beds differ in size, because the charge gas bed takes bulk water and the product beds take traces.
| Dryer position | Water load | Usual form |
|---|---|---|
| Charge gas, after compression | bulk, from the quench | 3A beads, 8 x 12 mesh |
| Ethylene product | trace | 3A beads or pellets |
| Propylene product, liquid full | trace | 3A, 4 x 8 mesh for a deep bed |
Grade selection shows how bed depth is worked out for the charge gas bed and for the polishers.
Olefin Dryer Packages and Replacement Charges
Cracker dryers are recharged at turnaround, so most enquiries are for a replacement charge in an existing vessel. Check the regeneration conditions at the same time. They usually decide how long a charge lasts.
Each vessel is loaded as a layered bed: graded ceramic support balls on the grid, the 3A charge above them and a hold down layer on top. For a new unit, SorbiTech Group supplies the twin tower TSA dehydration unit. The dehydration units and adsorber vessel design pages show how bed and vessel are sized together.
Related Olefin Plant Duties
- Petrochemical olefin purification, the sector map for crackers and polymer units.
- Oxygenate removal on 13X, ahead of an acid catalyst.
- LPG and NGL treating, for the C3 and C4 liquids.
- Regeneration temperature and cycle, for setting the heating step.
- Bulk 3A supply and manufacturing detail from Medaad, the group manufacturer.
Questions on Olefin and Cracked Gas Dryers
Can 3A molecular sieve dry butadiene and acetylene streams?
Yes. 3A is the grade used for butadiene, acetylene, methyl acetylene and propadiene, because these molecules stay outside the pore. Published design practice for these streams uses water loadings of 7 to 14 lb of water per 100 lb of sieve.
What happens if liquid water reaches an olefin dryer?
Molecular sieve releases a large amount of heat as it takes up water. A slug of liquid water can overheat the beads and damage them for good, so free water is knocked out of the feed before the dryer.
How dry does gas leave a molecular sieve olefin dryer?
A molecular sieve bed commonly takes water below 1 ppm. That level keeps ice out of the chilling train and the demethaniser that follow the dryer.
What is the highest temperature a 3A bed should see?
About 325 °C. Held above that, the crystal structure starts to break down and the lost capacity does not return. Olefin beds run well below it.
Is a water capacity published for SorbiTech Group 3A?
No typical water capacity is published for 3A. The capacity, packing density and crush strength that apply are agreed in the order specification, each with its test method.
Does a 3A dryer also take methanol out of the olefin stream?
No. Methanol is 3.6 Å across, wider than the 3A opening, so it passes through with the product. Methanol and other oxygenates are taken out on a separate 13X bed.
Quote for a Cracked Gas Dryer Charge
Send the stream, where the bed sits in the cracker, the vessel volume and the regeneration cycle it runs now.