Zone by zone sizing of a dryer bed, from the design inputs to guard layers and cycle time.

Related Solutions

Quick Answer

Molecular sieve bed design fixes four things in a dryer, the vessel diameter, the bed depth, the layer arrangement and the cycle time. The water load per adsorption step, the allowable pressure drop and the outlet water target drive all four.

  • ASTM D4179 crush strength
  • ASTM D4513 particle size
  • 8 x 12 and 4 x 8 mesh
  • Manufactured by Medaad

Request the TDS Request the SDS

Engineering GuideUpdated

A dryer bed is sized around one event, the moment water first reaches the outlet. The designer provides enough sieve to hold one step of water, adds depth for the band where drying is still under way, and fits the result in a vessel at a pressure drop the beads can carry. The grade is chosen first, as set out in types and grade selection.

Three Zones in a Working Dryer Bed

During adsorption, a dryer bed divides into three zones. Near the inlet lies the equilibrium zone, where the sieve has taken all the water it can hold from the wet gas. Below it is the mass transfer zone, where water loading falls from full to almost nil. Below that is the active zone of dry sieve, which holds the outlet at its target. Figure 01 shows the three in one bed part way through a step.

Figure 01 · Section through one dryer bed part way through an adsorption step, with gas flowing downward. Water loading is full in the equilibrium zone, falls across the mass transfer zone and is close to nil in the active zone.
WET GAS ININERT BALLSGUARD LAYEREQUILIBRIUMZONEMASS TRANSFERZONEACTIVE ZONESUPPORT BALLSDRY GAS OUTGAS FLOWWATER LOADINGBUFFER LAYER, TYPICALLY0.3 M OR MORESIEVE SATURATED WITHWATER FROM THE INLETTYPICALLY 0.2 TO 0.6 MMOVES DOWN THE BEDDRY SIEVE THAT HOLDSTHE OUTLET TARGETGRADED CERAMIC BALLS

Schematic, not to scale. Depths are typical ranges from published design practice, for guidance only.

As the step runs, the equilibrium zone grows and the mass transfer zone moves down. Breakthrough comes when the lower edge of that zone reaches the outlet and water starts to rise in the product. A design ends each step with a margin before that point. The theory behind the zones is introduced in what a molecular sieve is.

Design Inputs for a Molecular Sieve Dryer

A bed can only be sized against stated conditions. Each input below moves the result. When one is missing, a cautious assumption takes its place, and that usually adds sieve.

InputWhy it matters
Gas flow and compositionSets the actual volume, the velocity and the pressure drop
Operating pressure and temperatureSet gas density and the water loading the sieve can count on
Inlet water contentFixes the water load per step and so the equilibrium zone
Outlet water targetDecides how much dry sieve must remain at the end of a step
Adsorption step timeA longer step needs more sieve but fewer regenerations
Liquids and contaminantsAmine, glycol, heavy hydrocarbon and acid gas decide the guard layer and the grade
Allowable pressure dropTrades vessel width against bed depth and particle size
Regeneration gas and heatSets the water left on the sieve after heating, and so the working capacity

The same list applies whether the duty is natural gas dehydration, syngas and ammonia drying, electrolyser hydrogen drying or captured CO₂ drying. It holds as well for the many smaller dryers in chemical process plants. Only the weight given to each input changes.

Bed Diameter From Velocity and Pressure Drop

Superficial velocity is the gas flow divided by the empty cross section of the vessel. A higher velocity means a narrower vessel, but it raises the pressure drop and lengthens the mass transfer zone. Pressure drop is estimated with a modified Ergun equation, with constants for the particle shape and size.

Published practice designs for about 7.5 kPa per metre of bed. Across the whole bed that comes to about 0.35 to 0.55 bar, and a higher design figure is not recommended. Beyond it, the weight of the bed plus the drag of the gas can crush the lowest beads and make dust. Pressure drop also climbs over the life of a charge as beads settle, so the margin is taken at the start.

Adsorption normally flows downward. The velocity that would lift a bed is far lower than the velocity that would crush it, so flowing down presses the bed onto its support and allows a higher design velocity. Regeneration then flows upward at a much lower rate, and that rate is checked against lifting. Liquid duties such as LPG and NGL treating follow their own velocity rules and often flow upward during adsorption. A lifted bed rubs and wears its own beads, the main source of dust covered in service life and dusting.

Equilibrium Zone Sizing From Water Load

The water load is the inlet water content times the gas flow over one adsorption step. It is divided by a design capacity, which is lower than the capacity of fresh sieve. Published design practice takes about 13 kg of water per 100 kg of sieve for gas saturated at 24 °C (75 °F). That base is corrected down for warmer gas and for gas that is not fully saturated.

The design figure sits below fresh capacity for an ageing allowance. Capacity drops quickly over the first months of cycling and then slowly over years, through hydrothermal wear, coke and contaminants. The bed must still meet its target at the end of its planned life, so it is sized for the capacity expected then. The sieve mass that results, spread over the cross section chosen for pressure drop, gives the depth of the equilibrium zone.

For a duty that runs above 24 °C, or with a sieve such as 3A molecular sieve chosen to limit side reactions in sour gas dehydration, the correction is made against the grade data for that charge. The differences between grades are compared in 3A against 4A, 5A and 13X. 4A molecular sieve is the usual basis for sweet gas.

Mass Transfer Zone Length

The mass transfer zone is extra depth that is never fully loaded, so its length matters. A published correlation for beads of the common larger size gives about half a metre at normal velocities. Beads of the smaller size give roughly half that.

Four things lengthen the zone.

  • Higher gas velocity, since water has less contact time with each layer of beads
  • Larger particles, since water must travel further into each bead
  • Poor flow distribution, which lets one part of the front run ahead of the rest
  • Aged or partly fouled sieve, which takes up water more slowly

A deeper bed makes the zone a smaller share of the charge, so more sieve does useful work. As a rule of thumb, total bed depth is kept at least equal to the vessel diameter and not below about 1.8 m (6 ft), which helps flow spread evenly. A compound bed with smaller beads near the outlet shortens the zone where it matters most.

Guard Layer, Support Balls and Hold Down

Where the feed may carry amine, glycol, chlorides or liquid hydrocarbon, a buffer layer sits on top of the main charge, as Figure 01 shows. Activated alumina takes amine, caustic and chlorides, and it carries bulk water from a near saturated feed. The trade between the two materials is set out in molecular sieve against activated alumina, and the case for silica gel in molecular sieve against silica gel. In air prepurification the layer below the alumina is 13X molecular sieve, which takes CO₂ once the water is gone.

Graded ceramic balls support the bed, with the finest size next to the sieve and larger sizes below, so beads cannot pass into the outlet. A layer of hold down balls on top spreads the incoming gas and stops the surface from shifting during pressure changes. The vessel needs height above and below the bed for the inlet distributor, the hold down layer and the support, typically about 0.9 m (3 ft) in total. Nozzles, grids and distributors are covered under adsorber vessel design, and filling the vessel in loading and replacement.

Number of Beds and Adsorption Step Time

The simplest unit is a twin tower, where one bed adsorbs while the other is heated, cooled and held ready. Large flows often use three or four beds, with two or three adsorbing in parallel while one regenerates. Each bed then carries a share of the flow, which keeps vessel diameter and wall thickness practical. Packaged layouts are shown in dehydration units.

Adsorption steps of 8, 12, 16 and 24 hours are usual, and 8 to 12 hours is the most common. A shorter step needs less sieve and smaller vessels. It also means more thermal cycles per year, which shortens sieve life and works the switching valves harder. The step must leave enough time to heat, cool and stand by the other bed. How those regeneration stages are timed is set out in regeneration temperature and cycle.

Cold service affects the choice too. A dryer ahead of LNG pretreatment, helium recovery or a liquefaction train carries extra margin, because a short spell of wet gas can freeze the cold box. A unit in oil and gas processing feeding a sales line can usually accept a simpler layout.

Questions on Dryer Bed Design

Why does gas flow downward during adsorption?

Downflow lets the plant run a higher gas rate without disturbing the bed. Upward flow at the same rate would lift and churn the beads. Downflow also places the inlet at the top, where a guard layer can be inspected and topped up more easily. Regeneration runs the other way, so the water held near the inlet leaves from the top without crossing the dry outlet end.

How long does an adsorption step last?

In gas plants it is usually several hours, and many dryers switch on a fixed timer. Some units instead end the step on a moisture analyser reading or on a temperature profile in the bed. Heatless air dryers are the exception, with steps of a few minutes. As a charge ages, the same step time leaves a smaller margin before breakthrough.

What happens if a dryer bed is undersized?

Water breaks through before the step ends, so wet gas reaches the next unit. Operators then shorten the step, which raises the number of thermal cycles and speeds up ageing. An undersized bed may also be pushed to a higher velocity, which raises pressure drop and dust. In compressed air and gas service alike, the usual remedy is more sieve volume.

Can an existing vessel take a new grade?

Often it can, if the new grade has similar density and particle size. Check the volume, the pressure drop at design flow, the regeneration heat available and the support grid opening. A change from pellets to beads, or to a smaller size, changes the pressure drop and needs a new calculation before the charge is ordered.

How often should bed pressure drop be checked?

Many plants log it continuously and review the trend each week, always at a comparable flow. A record taken at start up gives the baseline. A steady slow rise is normal settling. A sudden jump points to caking at the top, a failed support or crushed beads, and calls for inspection at the next shutdown.

Request a Quote for a New Dryer Charge

Bed sizing starts from the gas. Send SorbiTech the flow and composition, the operating pressure and temperature, and the water content at the inlet. Add the outlet target and the step time intended, and name any amine, glycol, heavy hydrocarbon or acid gas in the feed. For a vessel already standing, give its inside diameter, the height available and the present charge.