Molecular SieveZeolite AdsorbentsBy SorbiTech™
Treater tower at a gas plant at dawn

Molecular Sieve Mercaptan and H₂S Removal

A regenerable 13X bed polishes the last mercaptans and H₂S out of gas after the amine unit.

Find My Solution

Quick Answer

Mercaptan and H₂S removal with 13X molecular sieve takes sulfur species out of natural gas and LPG to meet a sulfur specification. After an amine unit, a 13X bed takes hydrogen sulfide under 4 ppmv and mercaptan sulfur to 5 to 10 ppmv, then gives the sulfur up under heat so the charge is used again.

  • 13X molecular sieve
  • 5A for light species
  • Lead and lag beds
  • Crush strength by ASTM D4179
  • Tapped density by ASTM D4164
  • Manufactured by Medaad

Request the TDS Request the SDS

Updated

Removing Sulfur Species From Gas

Sales gas is sold on a total sulfur limit. An amine unit takes out the bulk of the hydrogen sulfide and carbon dioxide, but it leaves most of the mercaptans behind, with a little H₂S among them. Mercaptan and H₂S removal is the polishing step that takes those last traces out.

Because a sieve bed regenerates, it suits a steady sulfur load and a tight limit. Where the load is very small or comes and goes, a single use scavenger such as zinc oxide, or an activated carbon bed, is often cheaper.

Adsorption in the Sweetening Train

When the bed is heated it gives back a small, concentrated stream of hydrogen sulfide and mercaptans. That stream cannot be vented. It is cooled and routed to a sulfur recovery unit or back to the amine system, so the sulfur stays inside the plant.

Sulfur breakthrough is harder to see than water, so the beds are often run lead and lag. When the lead bed nears breakthrough it goes to regeneration, the lag bed becomes the lead, and a fresh bed takes the guard position.

Figure 01 · The sieve as a sulfur polisher, and where the sulfur goes
The molecular sieve polishing step in a gas sweetening line Sour gas passes an amine unit that removes the bulk hydrogen sulfide and carbon dioxide, then a 13X molecular sieve bed that polishes out the last of the sulfur, and leaves as sweet product. The regeneration gas from the sieve carries the desorbed sulfur and is routed to a sulfur recovery unit or back to the amine. SOUR GAS AMINE UNIT bulk H₂S and CO₂ 13X POLISH trace sulfur SWEET PRODUCT regen gas, sulfur laden TO SULFUR RECOVERY OR AMINE

Sulfur Limits After Treating

A 13X bed takes hydrogen sulfide and mercaptans down to single figure parts per million where the feed and the cycle are designed for it. Inlet levels swing with the upstream unit, so the values are typical.

ParameterTypical inlet Required outletUnit
Hydrogen sulfide50 to 500 under 4ppmv
Mercaptan sulfur10 to 200 5 to 10ppmv
Total sulfur, sales gasas above to the pipeline limitppmv

Sulfur limits are set by contract and vary by market.

13X and 5A for Mercaptan Removal

Hydrogen sulfide is small. The mercaptans grow larger from methyl through ethyl to propyl and heavier. The pore has to be wide enough for the largest sulfur molecule in the feed.

Figure 02 · Sulfur molecule size against the pore
Size of the sulfur compounds against the 5A and 13X pore openings Hydrogen sulfide is small and enters a 5 angstrom opening. Methyl, ethyl and propyl mercaptans grow larger and need the wider 10 angstrom opening of 13X. Drawn to scale by kinetic diameter. 13X OPENING, ABOUT 10 Å · ADMITS ALL 5A takes these 5A too small 5A ~5 Å H₂S 3.6 Å methyl mercaptan 4.5 Å ethyl mercaptan 5.4 Å propyl mercaptan 6.0 Å

Kinetic diameters are the published values.

Feed carriesBed
H₂S and methyl mercaptan only5A or 13X
Ethyl and heavier mercaptans13X, the widest pore
Heavy hydrocarbons as wellactivated alumina or silica gel guard over 13X

A layer of inert ceramic ball holds the charge at each end. Medaad, the group manufacturer, makes the sieve and the guard media; bulk detail is on Medaad. Capacity falls as the outlet limit tightens, because the last parts per million are the hardest to reach, so a bed sized for a few ppm total sulfur is larger and cycles more often. Bed design sets the depth.

Regeneration Steps for a Sulfur Bed

StepWhat happens Typical range
Adsorption The bed takes the sulfur down to spec until breakthrough approaches
Heating A heated slipstream of clean gas drives the sulfur back off 230 to 290 °C at the inlet
Cooling The same gas, unheated, brings the bed back to near the adsorption temperature

The heated gas must carry no oxygen, because oxygen and hydrogen sulfide make solid sulfur that plugs the pores. Regeneration must also be complete each cycle, or sulfur left on the bed brings breakthrough sooner next time. Hot cycling also ages the crystal slowly, as service life and dusting explains.

Design Scope for a Sulfur Polisher

The bed is designed around the sulfur species in the analysis, and the regeneration gas route is settled at the same time. A polisher follows a gas sweetening unit and runs as a twin tower TSA unit; adsorber vessel design shows the sizing. Where the scope includes a vessel, PuraSpecs takes the mechanical design and fabrication. The duty is found in oil and gas processing and oil refineries.

Request a Quote

Related duties

Beds That Handle Sulfur

01
Sour gas dehydration
Drying gas that still carries H₂S and CO₂, on a grade that will not make carbonyl sulfide.
View sour gas dehydration

Questions on Mercaptan and H₂S Removal

Does water in the gas affect mercaptan removal?

Yes. Water is held more strongly than any sulfur compound and takes capacity first. A bed sized for drying alone passes the feed sulfur once water breaks through, so the water section is designed first and the sulfur section is added to it.

Which sulfur compounds does 13X hold most strongly?

Mercaptans are held most strongly, then hydrogen sulfide, thiophene, sulfides and disulfides, with carbonyl sulfide weakest. Carbon dioxide is held less strongly than any of the sulfur compounds.

How much more mercaptan than H₂S does a bed hold?

By weight, mercaptans load to more than double the H₂S figure. Thiophene loads close to the mercaptans, sulfides and disulfides close to H₂S, and COS to about 20 to 25 percent of the H₂S loading.

Why is 5A not used for every mercaptan duty?

5A does not adsorb mercaptans larger than ethyl mercaptan. It does have a higher bulk density, a slightly higher H₂S capacity at very low concentrations, and it suppresses COS formation, so it suits feeds where only the light species are present.

How low can a sieve bed take hydrogen sulfide?

Published data show a sieve bed reaching 0.25 grains per 100 scf, about 6 mg/m³. That depth needs regeneration at about 315 °C held for an extended time.

Why do laboratory sulfur capacities look low next to plant results?

Laboratory tests are usually run to a breakthrough of 0.1 ppm, while plants usually work to 1 ppm. A capacity measured in the laboratory therefore reads lower than the bed delivers in service.

Quote for a Mercaptan Removal Bed

Include the gas flow and pressure, and say where the regeneration gas can be sent: a sulfur recovery unit or the amine system.

Request a Quote
Contact
Email[email protected] Call+971 56 777 3027