The molecular sieve glossary defines the technical terms used across SorbiTech Group guides on zeolite adsorbents: the grades 3A, 4A, 5A and 13X, how adsorption and regeneration work, how a bed is sized and loaded, and the test methods behind each specification. Every term has its own anchor link.

  • ASTM D4513 particle size
  • ASTM D4164 tapped density
  • ASTM D4179 crush strength
  • ASTM D4058 attrition

Request the TDS Request the SDS

BasicsUpdated

A molecular sieve glossary collects the terms engineers meet when they choose, size, load and run a zeolite adsorbent bed. Terms run in alphabetical order, with the four grades first. Each definition is short and points to the product or guide that covers the subject in depth.

0 to 9

3A molecular sieve
A Type A zeolite grade with a pore opening of about 3 Å. Water enters the pore while ethanol, olefins and carbon dioxide stay out, so 3A dries streams whose main component must not be held. It is regenerated at the low end, typically about 200 to 230 °C. See zeolite 3A.
4A molecular sieve
A Type A grade with an opening of about 4 Å. It is the usual basis for drying sweet gas, and gas plant dryers on 4A are commonly designed for an outlet below about 0.1 ppmv water. See zeolite 4A.
5A molecular sieve
A Type A grade whose window is opened by ion exchange from 4 to 5 Å. The pore admits straight chain molecules and keeps branched ones out, so 5A runs normal paraffin separation and forms the last layer of a hydrogen PSA bed. See zeolite 5A.
13X molecular sieve
A Type X zeolite with larger cages and a window of about 10 Å. It holds molecules too large for 4A, such as mercaptans and heavier hydrocarbons, and serves sulfur removal, carbon dioxide removal, oxygenate removal and PSA oxygen. See zeolite 13X.

A

Activated alumina
A porous aluminium oxide made by heating aluminium hydroxide until water leaves the solid. Its pores vary in size, so it adsorbs by polarity and does not sort molecules by size. It often shares a vessel with molecular sieve, as in air prepurification.
Adsorption
The holding of molecules on the internal surface of a solid, the adsorbent. A molecular sieve holds them inside its cages, and only molecules small enough to pass the window can be held.
Angstrom (Å)
A unit of length equal to a tenth of a nanometre. Pore openings and molecule sizes are given in angstroms: water is about 2.6 Å across and ethanol about 4.4 Å.
Attrition
The wear of particles as they rub together. Attrition loss by ASTM D4058 measures the fines a charge produces, and resistance to it matters on duties with many pressure switches an hour, such as air brake and CNG dryers.
Azeotrope
A mixture that boils at a fixed ratio, so distillation cannot separate it further. Ethanol and water stall at 95.6 percent ethanol by weight, and a 3A bed takes the ethanol past that point to anhydrous fuel grade.

B

Beads and pellets
The two formed shapes of molecular sieve. Zeolite crystal is bound with clay and formed into spheres or extruded pellets, and the shape and size are chosen against the vessel and the pressure drop the plant allows.
Binder
The clay that holds the zeolite crystal together in a bead or pellet. Liquid water, amine, glycol and wet acid gas can attack it and weaken the beads.
Breakthrough
The point at which the held component starts to appear at the bed outlet. A breakthrough test times the rise in outlet dew point on the oldest bed and shows how much capacity the charge has left.
BTX
The aromatic group of benzene, toluene and xylenes. In LNG feed gas they freeze in the cold exchanger, and on a 13X layer they can crack during hot regeneration and lay down carbon.

C

Cage and window
The cavities inside a zeolite framework are called cages, and neighbouring cages connect through windows. Every window in one crystal type has the same width, typically between 3 and 10 Å.
Carbonyl sulfide (COS)
A sulfur compound that forms when hydrogen sulfide and carbon dioxide held together on a molecular sieve react, giving COS and water. A narrow pore sieve limits its formation in sour gas dehydration.
Cold box
The cryogenic heat exchanger section of an air separation, helium or liquefaction plant. Water and carbon dioxide freeze there and block the passages, so the feed is dried and cleaned first.
Coking
Carbon laid down in the pores when heavy hydrocarbons, olefins or liquid left in the bed crack during hot regeneration. Coke blinds the pores and cannot be removed, and oxygen in the regeneration gas makes it worse.
Copper strip test
The ASTM D130 corrosion test for LPG and NGL. Mercaptans make a product fail it, so a 13X charge that holds them lets treated LPG meet its water and copper strip specifications in one step.
Crush strength
The load a single bead or pellet carries before it breaks, measured by ASTM D4179. It matters in deep beds and wherever rapid pressure swings load the bead, as in CNG dryers.

D

Desiccant
A material used to take up water and keep a gas, liquid or sealed space dry. Molecular sieve, silica gel and activated alumina are all desiccants, and each is strongest in a different part of the humidity range.
Dew point
The temperature at which water starts to condense from a gas. A dryer outlet dew point is set so that no water condenses or freezes at the coldest point downstream.
Dusting and fines
Fines are fragments and powder shed when beads rub, crush or are loaded badly. Dust raises the pressure drop and carries downstream, so a hard bead, careful loading and an outlet dust filter keep it in check. See service life and dusting.

E

Equilibrium zone
The part of the bed near the inlet where the sieve has taken all the water it can hold from the wet gas. It grows through the adsorption step while the mass transfer zone moves down.

H

Heat of adsorption
The heat released when a molecule is adsorbed. Water releases about 4,200 kJ per kilogram on molecular sieve and about 2,500 kJ on silica gel, and the stronger bond is why the sieve needs more heat to regenerate.
Hold down and support balls
Inert ceramic balls loaded below and above the adsorbent. Graded support balls on the grid spread the load and keep media out of the outlet, and a hold down layer on top keeps the beads still when the pressure changes.
Hydrothermal ageing
Loss of capacity caused by steam at regeneration temperature, which slowly dealuminates the crystal so the equilibrium water capacity falls cycle by cycle. A slow heating ramp with a soak and dry regeneration gas slow it.

I

Ion exchange
A manufacturing step that swaps the positive ions balancing the zeolite framework, called exchanged cations, to set the pore opening. Ion exchange opens the Type A window from 4 to 5 Å for the 5A grade.
Isotherm
A curve of the amount held against the amount in the gas at one temperature. For molecular sieve and water it rises almost straight up at the dry end, which is why a sieve bed dries so deeply.

K

Kinetic diameter
The smallest width a molecule presents as it tries to pass through an opening. Comparing it with the pore opening shows which grades admit a molecule. See types and grade selection.

L

Layered bed
A bed with two or more adsorbents in one vessel, each in its own layer. LNG pretreatment can stack alumina, 13X and 4A, and a hydrogen PSA bed stacks activated carbon, 13X and 5A.
Lead and lag beds
Two beds in series. The lead bed does the work and the lag bed behind it catches the breakthrough, and when the lead nears breakthrough it goes to regeneration and the lag bed takes its place.

M

Mass transfer zone
The band of the bed where water loading falls from full to almost nil. It is depth that is never fully loaded, and a higher gas velocity lengthens it. See dehydration bed design.
Mercaptans
Sulfur compounds found in natural gas, LNG feed and LPG. They are too large for the 4A pore, so they are held on a 13X layer. See mercaptan and H₂S removal.
Mesh size
The particle size range of a charge, given as a pair of screen numbers. The grade pages publish 8 x 12 and 4 x 8 mesh, and particle size is measured by ASTM D4513.
Molecular sieve
A crystalline adsorbent, nearly always a synthetic zeolite, whose pores all share one fixed width. It holds molecules small enough to enter those pores, lets larger ones pass, and holds water most strongly of all. See what is a molecular sieve.

N

Normal paraffins
Straight chain hydrocarbons. They slide end on into the 5 Å pore and are held, while branched and ring molecules pass, which is how 5A parts them from kerosene or naphtha.

O

Oxygenates
Hydrocarbon compounds that carry an oxygen atom, such as methanol, MTBE and dimethyl ether. At parts per million they harm acid catalysts, so a 13X bed holds them out of the feed.

P

Polarity
An uneven spread of electric charge across a molecule. Polar molecules such as water, ammonia and hydrogen sulfide are held firmly in the cage, and nonpolar molecules such as methane least of all.
ppmv
Parts per million by volume, the unit for trace water and contaminants in gas. Below about 0.1 ppmv water corresponds to a frost point near minus 90 °C at atmospheric pressure.
Pressure dew point
The dew point measured at line pressure, the usual figure for compressed air. A heatless desiccant dryer commonly reaches a pressure dew point of minus 40 °C.
Pressure drop
The loss of pressure as gas flows through the bed. It rises with gas velocity, bed settling and dust, depends on bead size, and a charge is replaced when it becomes unworkable.
Pressure swing adsorption (PSA)
A cycle that clears the bed by dropping the pressure, often in under a minute. It suits oxygen generation and hydrogen purification.

R

Regeneration
Driving the held water or contaminant off the bed so it can be used again. A thermal swing does it with hot gas through heating, hold and cooling steps. See regeneration temperature and cycle.
Regeneration gas
The gas passed through a bed to carry off what it releases during regeneration. It must be dry and free of oxygen, and heating usually runs upflow, below the velocity that lifts the bed.
Relative humidity
How much water the air or gas holds compared with the most it could hold at that temperature. A 4A fill is still taking up water at 10 percent relative humidity.

S

Silica gel
Amorphous silicon dioxide with fine, irregular pores of many sizes. It carries a large water load in humid conditions and gives it back with mild heat. See molecular sieve vs silica gel.
Sour and sweet gas
Sour gas carries hydrogen sulfide and often carbon dioxide, and sweet gas has had them removed. 4A is the usual basis for drying sweet gas.

T

Tapped density
The packing density of a formed adsorbent after mechanical tapping, measured by ASTM D4164. It links the mass of a charge to the vessel volume it fills.
Thermal swing adsorption (TSA)
A cycle that clears the bed with hot gas, on a cycle of hours. Most gas dryers run a thermal swing, often as a twin tower unit with one bed on line while the other regenerates.
Type A and Type X
The two synthetic zeolite frameworks behind the common grades. 3A, 4A and 5A are Type A, and 13X is Type X, a more open framework with larger cages. The framework type is fixed at synthesis.

V

Vacuum swing adsorption
A pressure swing cycle that regenerates the bed below atmospheric pressure. Ethanol dehydration runs 3A beds in pressure and vacuum swing, and VPSA oxygen units run 13X.

Z

Zeolite
A crystalline aluminosilicate built from silicon, aluminium and oxygen into a rigid framework of cages. Zeolites occur in nature, but industrial molecular sieve is made synthetically so every crystal in a batch has the same window.

Questions on Molecular Sieve Terms

What is the difference between a zeolite and a molecular sieve?

Zeolite names the crystal. Molecular sieve names the working adsorbent: synthetic zeolite crystal bound with clay into beads or pellets and dried for service. Every grade SorbiTech Group supplies is a zeolite, either Type A or Type X.

What do the numbers in 3A, 4A, 5A and 13X mean?

For the A grades the number gives a rough idea of the window in angstroms. 13X does not follow that pattern, since its window is about 10 Å. The letter names the crystal type.

Is a dew point the same as a ppmv figure?

No. Both describe how dry a gas is, but a dew point is a temperature and ppmv is a concentration, and one converts to the other at a stated pressure. Gas plant specifications usually give ppmv, while compressed air specifications usually give a pressure dew point.

Which terms matter most when a dryer bed is sized?

Water load per step sets the equilibrium zone, the mass transfer zone adds depth that is never fully loaded, and gas velocity sets the pressure drop. Dehydration bed design works through them in that order.

Which test methods sit behind a molecular sieve specification?

Particle size is measured by ASTM D4513, tapped density by ASTM D4164, crush strength by ASTM D4179 and attrition by ASTM D4058. Quality and specification sets out what each method checks.

Ask About a Term or a Duty

When a definition raises a question about your own bed, send SorbiTech the stream, the component to remove, the outlet target, and the flow, pressure and temperature. Say which adsorbent is in service now and how long its cycle runs.

Request a Quote