Molecular Sieve Biogas Upgrading
Drying biomethane to the grid dew point after bulk carbon dioxide removal, behind a carbon guard.
Quick Answer
Biogas upgrading turns raw digester or landfill gas into biomethane for the grid or for vehicle fuel. After bulk carbon dioxide removal, a molecular sieve bed dries the gas to the water dew point the grid operator sets. A 4A bed is the usual charge. Siloxanes and sulfur are taken out upstream.
- Molecular sieve 4A and 3A
- Activated carbon guard upstream
- Inert ceramic ball support
- Crush strength by ASTM D4179
- Manufactured by Medaad
Updated
Drying Biomethane to Grid Specification
Raw biogas from a digester or a landfill is about half methane and half carbon dioxide. It is wet and carries traces of hydrogen sulfide and siloxanes. Upgrading turns it into biomethane: almost pure methane, clean enough for the grid or for vehicle fuel.
Bulk carbon dioxide is usually removed by water scrubbing, membranes, an amine unit or a pressure swing unit. These handle the large volume economically. The molecular sieve comes after, as the drying step.
Siloxanes and the Activated Carbon Guard
Water comes off a molecular sieve when the bed is heated, so the bed can be regenerated. Siloxanes, the silicon compounds from consumer products in the waste, behave differently. On the sieve they break down and leave a hard silica deposit in the pore. Heat does not remove it. Each cycle adds a little more until the bed has to be replaced.
So the sieve is never first in line. A bed of activated carbon upstream takes out the siloxanes and most of the hydrogen sulfide. The carbon is replaced when spent. The zeolite behind it goes on being regenerated.
The carbon guard takes the siloxanes and hydrogen sulfide out first, so the sieve behind it stays clean and regenerable.
Grid Injection Targets
Grid biomethane is held to a methane content, a carbon dioxide limit, a water dew point, and a siloxane limit that protects the burners and the engines downstream. The molecular sieve holds the dew point; the guard and the bulk step hold the rest. The values are typical of a grid injection spec.
| Parameter | Target | Held by |
|---|---|---|
| Methane content | above 96 | Bulk CO₂ removal |
| Carbon dioxide | below 2 to 3 percent | Bulk CO₂ removal |
| Water dew point | to the grid limit | Molecular sieve dryer |
| Siloxanes | below 0.1 mg per Nm³ | Carbon guard upstream |
Grid specs are set by the network operator and vary by country. Confirm the one that applies.
4A or 3A Drying Charge
The drying grade is 4A. On a small plant, 3A can save energy because it regenerates at a lower temperature. Both adsorb water and keep methane out of the pore. The bed is laid out like any thermal swing dryer, with inert ceramic balls at each end. Bed design sets the depth and the vessel.
The carbon guard is sized for the measured siloxane and hydrogen sulfide load. It is changed on a schedule, before it breaks through.
Water leaves the bed on heating. Siloxane leaves a silica deposit that stays.
Packaged Upgrading Units and Dryer Charges
Biogas plants are small and often built in stages, which suits a modular unit. The group supplies the biogas upgrading unit as a package, with the dryer laid out as in a molecular sieve dehydration unit. For an upgrader already in service, supply is the drying charge and its guard.
Biogas Plants and Neighbouring Duties
The plant view, from digester to grid entry, is under biofuel and biogas plants. Pipeline gas follows natural gas dehydration, and what ages a charge is set out in service life and dusting.
Beds on Renewable Gas
Biomethane Dryer Questions
How is a biomethane dryer regenerated?
On a thermal swing. A heated slipstream of dry gas, typically 200 to 250 °C at the inlet, drives the water off. The same gas, unheated, then cools the bed before it goes back on line. On a small plant the heat can come from the site itself.
Does landfill gas need a different set up from digester gas?
Landfill gas carries more siloxanes and a wider mix of trace contaminants, so its guard bed is larger and is changed more often. The dew point also depends on the end use. Gas for a high pressure grid needs a lower dew point than gas burned on site.
What happens if the bulk step leaves carbon dioxide in the gas?
Carbon dioxide that slips past the bulk step loads the sieve and cuts its water capacity. Holding the bulk step to its own specification protects the dryer cycle.
Why must oxygen be kept out of the regeneration gas?
Hydrogen sulfide left in the gas ages the sieve. With oxygen present during heating, it can also lay down sulfur on the bed.
What protects the dryer from scrubber water and dust?
A knockout and a coalescer between the bulk step and the dryer stop a slug of free water from swamping the bed. A hard bead, careful loading and an outlet dust filter keep fines out of the grid line.
Quote for a Biomethane Dryer
The dryer is sized to the grid dew point, with a carbon guard ahead of the bed for the siloxanes and H₂S.
Request the TDS and SDS
Name the grade, 4A or 3A, and the documents you need for the biomethane dryer.