Molecular Sieve for Air Separation Plants and Industrial Gases
Front end purifiers, oxygen VPSA beds and helium guard beds for industrial gas sites.
Quick Answer
Molecular sieve for air separation plants is the zeolite adsorbent that cleans feed air ahead of cryogenic units, separates oxygen in VPSA units and purifies helium. 13X takes water and carbon dioxide, which turns solid at about minus 78 °C, from feed air. On VPSA skids it holds nitrogen, so oxygen leaves at 90 to 95 percent.
- Zeolite 13X and 5A
- Beads and pellets
- Media made by Medaad
- Crush strength to ASTM D4179
- Attrition to ASTM D4058
Industrial gas sites use molecular sieve in three kinds of plant. A cryogenic air separation unit cleans its feed air before the cold box. An on site oxygen unit uses the zeolite to separate oxygen from nitrogen. A helium train dries and cleans natural gas before its own cold box.
Bed life on an air plant depends mostly on what reaches the vessel. Merchant argon, hydrogen and carbon dioxide each add a drying or polishing step.
Front end purifiers and VPSA oxygen skids run on 13X. Smaller oxygen concentrators use 5A.
Prepurification and Oxygen VPSA Packages
SorbiTech Group builds the complete units that hold the sieve on gas sites. The cryogenic ASU prepurification package removes water and carbon dioxide from compressed air ahead of the cold box. The oxygen VPSA package makes oxygen at the user's site. Vessels and skids come from PuraSpecs, the group's equipment company.
Air Separation Front End, Oxygen Skid and Helium Train
The bed has a different job in each plant. In a cryogenic plant it is a purifier that protects the cold box. On an oxygen skid it makes the separation. In a helium train it is a guard bed ahead of the cold box.
Cryogenic Air Separation Plants
The front end sits after the main air compressor and the aftercooler or chiller, ahead of the cold box. Two adsorber vessels work in turn. One is on line while the other regenerates with heated waste gas from the cold box. The beds take out water, carbon dioxide and trace hydrocarbons such as acetylene. An activated alumina layer from Medaad often sits at the air inlet, ahead of the zeolite.
Water and carbon dioxide freeze in the main heat exchanger and cut plant output. Acetylene and heavier hydrocarbons collect in the liquid oxygen sump, where they become a safety concern. Nitrogen and argon have no bed of their own. They rely on the same front end. The duty is set out in full under air prepurification.
On Site Oxygen by VPSA
A VPSA unit is built at the user's site, such as a steelworks, glass furnace, pulp mill or wastewater plant. It replaces delivered liquid oxygen where demand is steady. A blower feeds air to the adsorber vessels. The zeolite holds nitrogen and passes oxygen, and a vacuum pump clears the bed between cycles. A buffer tank evens out the product flow, and an inlet guard layer keeps moisture off the working bed. Bed and cycle design are covered under oxygen generation.
Helium Purification
Helium is recovered as a side stream of natural gas processing on certain fields. Feed composition changes from field to field. The guard bed ahead of the cold box is therefore specified for each source gas. It dries the feed and removes the components that would freeze. Solids that pass it plug the cold box passages, and helium output stops until the box is thawed. After the cold box, a pressure swing unit upgrades crude helium to sales purity. Both steps are described under helium recovery. The helium cold box runs near minus 190 °C.
Each line runs from the air intake to the product. Blue boxes mark the adsorber steps.
Adsorber Life on Air Plants and Merchant Gas Purity
Short bed life on an air plant usually traces back to the feed. A chiller trip or a direct contact cooler upset carries liquid water into the vessel. Air drawn near a refinery, flare or busy road carries more hydrocarbons and nitrogen oxides than the design allowed. Regeneration gas that is too cool, or a heating step cut short, leaves water behind cycle after cycle. On VPSA skids, fast valve cycling rubs beads into dust that lifts with the flow.
Merchant products leave the site against a purity specification, and several carry an adsorber step of their own. Where crude argon is deoxidised with hydrogen, a dryer takes out the water formed. A merchant hydrogen plant purifies reformer gas by pressure swing, the duty covered under hydrogen purification. Reformer and electrolyser sites themselves are mapped under hydrogen production.
Raw carbon dioxide from an ammonia, ethanol or fermentation source is dried ahead of the liquefier. Dry product keeps ice out of the liquefier and corrosion out of cylinders, as described under carbon dioxide drying. Instrument air dryers on gas sites are a separate duty, covered under compressed air drying. For each merchant product, the purity limit agreed with the customer sets the dryer duty.
Related Gas Plant Duties
Helium trains often sit behind an LNG train, covered under LNG liquefaction plants. Heating steps for a TSA front end are set out under regeneration temperature and cycle. Bead wear on fast cycling skids is covered under service life and dusting.
Questions on Molecular Sieve for Air Separation Plants
Why can a plant air dryer not protect a cold box?
A compressed air dryer is judged on a water dew point some tens of degrees below zero, and it leaves the carbon dioxide in. A front end must take out both, to limits far below anything a plant air dryer works to.
Is a thermal swing or a pressure swing front end used?
Both run. A thermal swing unit heats the bed, uses less purge gas and runs cycles of hours. A pressure swing unit cycles in minutes and uses more air as purge, so its beads need more mechanical strength.
Why does a 13X bed hold nitrogen and pass oxygen?
The two molecules are almost the same size, so a pore cannot sort them. Nitrogen has a stronger quadrupole, and the cations in the zeolite hold it harder.
What sets the purity ceiling of a VPSA oxygen unit?
Argon. It behaves much like oxygen on a 13X bed and passes through with the product.
How clean is the gas leaving a helium guard bed?
A layered bed of 13X and 4A holds water below 0.1 ppmv and carbon dioxide below 1 ppmv at the guard outlet. The cold box designer sets the exact targets.
Request a Quote for Air Plant Adsorbents
SorbiTech supplies Medaad zeolite, activated alumina and support media for front end, oxygen and helium beds. The group also offers a complete oxygen VPSA package. For a quote, give the plant type and product gas, the flow, pressure and inlet temperature, the contaminants and the purity limit. Add the cycle and the regeneration gas. For a change out, add the vessel size and the current bed loading.