Molecular Sieve Sour Gas Dehydration
A narrow pore sieve dries gas that still carries H₂S and CO₂, with little carbonyl sulfide made.
Quick Answer
Sour gas dehydration dries natural gas that carries hydrogen sulfide and carbon dioxide, using a narrow pore molecular sieve that limits carbonyl sulfide formation. A 3A bed takes the water below 0.1 ppmv for a cryogenic or LNG plant, and because the acid gas cannot enter its pore, very little COS forms on the way.
- 3A molecular sieve
- Acid resistant 4A
- Silica gel guard layer
- Crush strength by ASTM D4179
- Attrition by ASTM D4058
- Manufactured by Medaad
Updated
Drying Gas That Carries Acid
Most of the acid gas is washed out first in an amine unit. The gas leaving it is saturated with water and still holds a little H₂S and CO₂. Sour gas dehydration is the drying step that follows, usually to below 0.1 ppmv so the gas can go on to a cryogenic recovery or LNG plant.
The duty sits in oil and gas processing plants. Once the acid gas is fully out, drying is ordinary natural gas dehydration. Taking the sulfur out is a separate duty, mercaptan and H₂S removal.
The Carbonyl Sulfide Problem
When hydrogen sulfide and carbon dioxide are both held on a molecular sieve, they react to make carbonyl sulfide, COS, and water. The sieve speeds this up, because it holds the two acid gases close together and pulls the water away. The reaction runs fastest when the bed is hot, so most COS is made during regeneration.
The COS leaves with the gas, turns back into hydrogen sulfide when it meets water downstream, and can push the product past its total sulfur limit.
Grade Choice Under Acid Load
On sour gas the grade is a trade off. The grades that hold the most water also make the most COS, and the bed has to meet both the water target and the total sulfur limit.
| Grade | Takes up CO₂ and H₂S | COS made | Where it fits on sour gas |
|---|---|---|---|
| 3A | No, the pore is too small | Very low | The usual low COS choice |
| 5A | Some | Limited | Where a little sulfur pickup is wanted too |
| 4A | Yes | High | Only as an acid resistant, COS suppressed grade |
| 13X | Yes, freely | High | Bulk CO₂ duty, not the sour dryer |
3A holds less water than 4A, so the bed is larger for the same duty, but it protects the sulfur specification. Where the capacity of 4A is needed, an acid resistant, COS suppressed 4A takes the place of the standard grade.
Layered Bed and Acid Resistance
Wet acid gas slowly breaks down the clay binder that holds the beads together. In an upset it turns to dust and the pressure drop rises. Acid resistant grades use a binder built for this service.
A silica gel guard layer goes on top. It catches amine or caustic carried over from the sweetening unit and takes the first of the water. The drying sieve sits below it on inert support media. Bed design covers the depths.
| Parameter | Typical value |
|---|---|
| Inlet water | saturated |
| Residual H₂S and CO₂ at the dryer | low, after the amine unit |
| Outlet water | below 0.1 ppmv |
| Outlet total sulfur | to the product sulfur limit |
Section through one dryer vessel, top to bottom.
Regeneration With Acid Present
| Step | What happens | Typical range |
|---|---|---|
| Heating | A heated slipstream of dry gas drives the water off the bed | 200 to 290 °C at the inlet |
| Ramp | The heat is brought up slowly, with a soak | a few degrees per minute |
| Cooling | The same gas, unheated, brings the bed back down | to near the adsorption temperature |
| Damage limit | The crystal degrades if the bed is held too hot | above about 325 °C |
The regeneration gas leaves carrying the water, the H₂S, the CO₂ and the COS the bed made, so it cannot be vented. It is cooled, the water is knocked out, and the gas goes back to the amine system.
A fast ramp boils water off the top of the bed onto the cooler layers below, where it pools and leaches the binder. Air is kept out of the feed and the regeneration gas, because oxygen turns H₂S into solid sulfur that plugs the pores. Regeneration and service life treat both in full.
Packaged Trains for Sour Service
The acid load affects the grade, the guard layer, the vessel metallurgy and the regeneration route together. A sour service train pairs a gas sweetening unit with a twin tower TSA dehydration unit; the dehydration units and adsorber vessel design pages show the sizing. Where the scope includes a vessel, PuraSpecs takes the mechanical design and fabrication. For a train already running, the scope can be the replacement charge alone, made by Medaad, the group manufacturer.
Beds on Sour Service
Questions on Sour Gas Dryers
Where does carbonyl sulfide made in the dryer end up?
It travels on with the dry gas. Where liquids are recovered downstream, the COS concentrates in the propane fraction, and that product then needs its own treater.
Does the COS reaction affect the water specification too?
Yes. The reaction makes water as well as COS, and that water forms inside the bed. It limits how dry the outlet gas can get, as well as adding sulfur.
Is there published plant evidence for low COS grades?
Yes. In one published plant case the feed carried 0.70 ppm H₂S and no COS. With a standard 4A charge the product held 0.25 ppm COS. After a change to a COS minimising sieve, COS at the outlet was zero.
How much hydrogen sulfide can a sieve dryer feed carry?
Published design guidance caps the feed at about 1500 ppm H₂S, set by both bed capacity and acid attack on the sieve. Above that, more of the acid gas has to come out upstream.
How is COS written into a dryer specification?
Buyers usually set a limit on COS made across the dryer next to the outlet water figure. One published dryer specification, for example, allows no more than 1.0 ppmw of COS produced.
Quote for a Sour Gas Dryer Charge
Include the type of amine unit upstream and any COS or total sulfur readings taken on the present charge.