Molecular SieveZeolite AdsorbentsBy SorbiTech™
Adsorption vessel skid at a gas processing site

Molecular Sieve for Hydrogen and Carbon Capture

Reformer PSA beds, electrolyser dryers and captured CO₂ dryers along the hydrogen chain.

Request Technical Consultation

Quick Answer

Molecular sieve for hydrogen and carbon capture is the zeolite adsorbent in reformer PSA units, electrolyser hydrogen dryers and dryers on captured carbon dioxide. Electrolyser dryers on 3A typically reach a pressure dew point of minus 40 to minus 70 °C. Reformer PSA beds with a 5A layer deliver hydrogen at purities up to 99.9999 percent.

  • Zeolite 3A, 5A and 13X
  • Beads and pellets
  • Media made by Medaad
  • Crush strength to ASTM D4179
  • Attrition to ASTM D4058

Request the TDS Request the SDS

Hydrogen production uses adsorption at several points along the plant. On a steam methane reformer, a pressure swing adsorption unit separates hydrogen from the shifted gas. A water electrolyser makes gas that is free of carbon but wet, so a dryer follows the stack. In both cases the sieve protects compressors, pipelines, storage and the hydrogen user from water and trace impurities.

Three more duties sit around hydrogen production. A reformer fitted with carbon capture yields carbon dioxide that is dried before compression and transport. Hydrogen sold to fuel cell users carries its own purity standard. Hydrogen shipped as ammonia meets adsorption again, at the synthesis loop and at the cracker on arrival.

Reformer PSA beds carry 5A among their layers. Electrolyser and captured CO₂ dryers run on 3A.

Hydrogen PSA and CO₂ Dryer Packages

SorbiTech Group builds the complete units that carry the sieve along a hydrogen chain. The hydrogen PSA purification package takes shifted reformer gas. Electrolyser hydrogen and captured carbon dioxide are dried in the twin tower TSA dehydration unit, where one tower dries while the other is heated. Vessels and skids come from PuraSpecs, the group's equipment company.

CapturedCO₂Topipeline1Knockoutand filterProcess unit2FirstcompressionProcess unit3Sievedryer3A media4Dense phasecompressionProcess unit
Treatment train · Captured CO₂ from the amine stripper through a 3A dryer to the transport pipeline

Steam Reformer, Capture Plant and Electrolyser Routes

Each route puts adsorption at a different unit. Adding capture to a reformer keeps the PSA and adds a carbon dioxide dryer.

RouteWhere adsorption appearsDuty
Steam methane reformer with shift converter (grey)The PSA unit after the shift converter. Activated carbon and zeolite layers hold back carbon dioxide, methane, carbon monoxide and nitrogen. Tail gas returns to the reformer burners as fuel.Hydrogen PSA purification
Steam methane reformer with carbon capture (blue)The same PSA, fed leaner gas where capture sits on the shifted gas. A further adsorption point appears on the carbon dioxide leaving the amine stripper.Captured CO₂ drying
Water electrolysis, alkaline or PEM stackA dryer after the gas separator and the deoxo unit, ahead of compression and storage. There is no carbon to remove, so drying is the adsorption duty.Electrolyser hydrogen drying
Figure 01 · Adsorption points on the reformer and electrolysis routes
REFORMER ROUTE, CAPTURE WHERE FITTEDREFORMERAND SHIFTAMINECAPTUREHYDROGENPSAMOLECULAR SIEVEHYDROGENPRODUCTCAPTURED CO₂CO₂ DRYERMOLECULAR SIEVECOMPRESSIONAND TRANSPORTELECTROLYSIS ROUTEELECTROLYSERDEOXOHYDROGENDRYERMOLECULAR SIEVECOMPRESSIONAND STORAGE

Blue boxes are adsorption steps. On a plant with capture, carbon dioxide leaves the amine unit for its own dryer.

Conditioning Captured CO₂ for Transport and Storage

Captured carbon dioxide is a product stream with its own specification, set by the pipeline or storage operator. On a blue hydrogen plant, an amine unit takes it from shifted gas, flue gas, or both. It leaves the stripper at low pressure and saturated with water. Before any adsorbent sees it, a knockout drum and a coalescing filter remove liquid water and amine carryover. Solvent and its degradation products foul a dryer bed, so they come out first.

The captured CO₂ dryer usually sits between compressor stages, once compression has knocked out bulk water. A Medaad activated alumina layer can take free water ahead of the sieve. The final compressor stages then raise the dry gas to dense phase for a pipeline. For shipping, the gas is liquefied instead, which adds a cold section after the dryer.

Water left in carbon dioxide forms carbonic acid, which corrodes carbon steel pipe and vessels. At transport pressure it can also form hydrate. The transport specification therefore sets the water limit, and dryer design starts there. A pipeline and a shipping terminal may set different limits for the same gas. 3A suits this duty because water, at 2.6 Å, enters its 3 Å pore and carbon dioxide, at 3.3 Å, does not.

Fuel Cell Hydrogen Purity and Ammonia as a Carrier

The end user sets the purity. A refinery hydrotreater tolerates impurities that a fuel cell stack does not. Fuel cell standards limit carbon monoxide, sulfur compounds, ammonia and water, because each attacks the stack catalyst or membrane. A PSA unit or dryer for fuel cell supply is specified to that standard.

Hydrogen shipped as ammonia meets adsorption at both ends of the chain. At the synthesis loop, makeup gas drying protects the synthesis catalyst. At the receiving terminal, a cracker splits the ammonia back into hydrogen and nitrogen. A PSA after the cracker then removes nitrogen and unconverted ammonia. It is specified from the cracked gas analysis.

Related Hydrogen and Capture Duties

Layer order in a reformer PSA bed is set out under hydrogen purification. Refinery hydrogen networks are covered under oil refineries. Ammonia front ends sit with chemical process plants. Heating and cooling steps are in regeneration temperature and cycle.

Questions on Molecular Sieve for Hydrogen and Carbon Capture

Why does an electrolyser dryer use 3A when hydrogen is so small?

Hydrogen is smaller than the 3 Å window and nonpolar, so a zeolite of any pore size barely holds it. The narrow pore keeps other molecules out. Its capacity goes to water, and little else comes off at regeneration.

Where does a recombiner sit relative to the hydrogen dryer?

Ahead of it. The recombiner burns residual oxygen to water, which adds moisture. The gas leaves it hot, and a bed holds less water from warm gas, so the cooler between the two is part of the dryer design.

An electrolyser dryer no longer holds its dew point. What is checked first?

The regeneration temperature. It is the usual cause when a running unit loses its dew point.

Does a captured CO₂ dryer lose product at each regeneration?

Only the gas in the void volume of the vessel. A 3A bed holds no carbon dioxide, so water and the carrier gas are all that come off when it is heated.

What water level does captured CO₂ transport usually need?

Typically tens of ppmv for pipeline transport and liquefaction. That is a general guide only. The pipeline or storage operator sets the figure the dryer is designed to.

Quote for Hydrogen PSA and CO₂ Dryer Media

SorbiTech supplies molecular sieve, activated alumina and activated carbon for each route. The group also offers a hydrogen PSA purification package. Tell us the route, whether carbon is captured, and the duty. Add the measured feed analysis, the pressure and flow, the limit the end user sets, and the regeneration heat available on site.

Request a Quote
Contact