Molecular Sieve Quality and Specification, Agreed Order by Order
Each order carries its own specification, with properties, limits and the standard method that measures each one.
Quick Answer
Molecular sieve quality at SorbiTech Group is agreed order by order. Each order carries a specification that names the grade, the form and the nominal size, the properties that matter for the duty, a limit for each property and the recognised test method that measures it, such as ASTM D4179 for crush strength.
- ASTM D4513 particle size
- ASTM D4164 tapped density
- ASTM D4179 crush strength
- ASTM D4058 attrition loss
- Manufactured by Medaad
Zeolite adsorbent from the group is first shortlisted on the grade pages. Their values are typical, published for guidance only, and serve grade selection and early design work.
The order then fixes the numbers that count. The quotation records the values agreed for the order.
What an Order Specification Covers
The specification starts with identity. It states the zeolite type, the cation form and the physical form, bead or pellet. It gives the nominal size range and the pack format. Published pack formats are 25 kg drums, 150 kg drums and 850 kg big bags. A nitrogen blanket is a published option for hygroscopic grades.
Next come the properties tied to the duty. A deep dryer bed calls for attention to strength and to fines. A charge sized by volume needs a packing density to convert volume into mass. A dehydration duty needs a water capacity and a residual water limit. The buyer and SorbiTech select the properties that apply and set a limit for each one.
Each property in the specification carries its test method. Where a recognised standard exists, the specification names it. Where none exists, it states the conditions of the measurement, such as temperature and humidity. A value without its method is hard to compare between suppliers or between deliveries. The specification is agreed at the quotation stage.
Properties and Recognised Test Methods
Zeolite molecular sieve is usually specified on a short set of physical and adsorption properties. ASTM test methods written for catalysts and catalyst carriers are the recognised standards for most of the physical ones. The adsorption properties have no single standard method, so their measurement conditions are written into the specification. Which rows apply, and the limits against them, depend on the duty.
| Property | What It Tells the Plant | Recognised Standard Method |
|---|---|---|
| Particle size distribution | Share of beads or pellets inside the nominal size range. It bears on pressure drop and on how the bed packs. | ASTM D4513, particle size distribution of catalytic materials by sieving |
| Tapped packing density | Mass that fills a given bed volume. It converts a bed volume into a charge weight. | ASTM D4164, mechanically tapped packing density of formed catalyst and catalyst carriers |
| Crush strength | Load at which a single bead or pellet breaks. It relates to the weight of a deep bed and to pressure changes. | ASTM D4179, single pellet crush strength of formed catalysts and catalyst carriers |
| Attrition and abrasion loss | Fines produced when particles rub together during handling, loading and service. | ASTM D4058, attrition and abrasion of catalysts and catalyst carriers |
| Equilibrium water capacity | Water held at a stated temperature and humidity. It indicates the adsorption activity of the zeolite. | Gravimetric uptake, with temperature and humidity stated in the specification |
| Residual water | Water left in the sieve as packed. It reflects activation and the sealing of the pack. | Gravimetric loss on heating, with the temperature stated in the specification |
Test Reports and Order Documents
The order states which test documents are required, if any, and which properties they report. Buyers commonly ask for a test report against the agreed specification and for packing and marking details. A buyer who needs a particular document should name it in the enquiry. It is then written into the quotation.
A report follows the same rule as the specification. It states results for the properties named in the order, measured by the methods named there. It does not extend to properties the order leaves out. A plant that tracks a property of its own, such as water capacity at a particular condition, should write it into the specification at the enquiry stage.
The arrangements that apply across the group are described in the group quality framework. The production route at Medaad is set out under manufacturing. Questions on a specification or a document go through the enquiry form.
Related Pages on Grades and Production
| Page | What It Covers |
|---|---|
| Zeolite grades | Typical values for 3A, 4A, 5A and 13X |
| Manufacturing | The production steps that set strength, pore opening and dryness |
| Service life and dusting | How crush strength and attrition show up in a working bed |
| 3A vs 4A vs 5A vs 13X | The four grades compared by pore width and duty |
Questions on Specifications and Test Methods
Is there a standard method for water capacity?
No single standard method exists. The uptake is measured by weight, and the specification states the temperature and humidity of the measurement so results can be compared between deliveries.
Can my plant specification be used for an order?
Yes. Name the properties, the limits and the test methods your specification calls for in the enquiry, and attach existing data sheets. The agreed values are then written into the quotation.
Which properties matter most for a deep dryer bed?
Crush strength and attrition loss, because the lowest beads carry the weight of the bed and every pressure change. Particle size distribution matters too, since it sets how the bed packs and the pressure drop it gives.
Which documents can an order include?
Buyers commonly ask for a test report against the agreed specification and for packing and marking details. Any document the order needs should be named in the enquiry so it is written into the quotation.
Can I get a TDS or SDS before ordering?
Yes, on request. Ask for the TDS and SDS through the document request form and name the grade. Test reports for a delivery are a separate matter, agreed in the quotation.
Request a Quote Against Your Specification
Describe the duty, the grade or form in mind and the quantity. Name the properties your plant specifies and the limits it needs. State any test methods your own specification calls for. List any test documents the order needs. The quotation records the values agreed for the order. Existing data sheets or specifications can be attached.