Molecular SieveZeolite AdsorbentsBy SorbiTech™
Treater vessels with LPG storage spheres behind

Molecular Sieve LPG and NGL Treating

Liquid phase 13X beds that dry propane, butane and NGL and remove mercaptans for the copper strip test.

Find My Solution

Quick Answer

LPG and NGL treating dries propane, butane and mixed liquids in the liquid phase with a molecular sieve bed that removes water without holding the product. A 13X charge also holds the mercaptans, so the treated product meets its water specification and passes the copper strip corrosion test in one step.

  • Molecular sieve 13X, 4A and 3A
  • Copper strip test ASTM D130
  • Liquid phase downflow beds
  • Crush strength by ASTM D4179
  • Manufactured by Medaad

Request the TDS Request the SDS

Updated

Drying Liquid Hydrocarbon

Liquefied petroleum gas and natural gas liquids are sold on two properties. They must be dry, and they must not corrode copper. Water left in liquid propane or butane forms hydrates in cold storage and transport, and blocks valves. Mercaptans and hydrogen sulfide corrode metal and smell. LPG and NGL treating removes both, so the product meets its water and copper strip spec.

A molecular sieve bed does both jobs while full of liquid.

Drain Before Heating a Liquid Phase Bed

Liquid is dense and does not compress. A gas dryer only heats and cools. A liquid bed must first be emptied of product.

A spent bed is taken off line, depressured and drained. Only then is it heated with a hot gas purge to drive off the water and sulfur. It is then cooled and refilled with liquid. Liquid left in the bed when the heat comes on cracks and lays down coke that cannot be removed.

Figure 01 · The liquid phase cycle
The liquid phase treating cycle for LPG and NGL The bed adsorbs while full of liquid, is then depressured and drained of liquid, heated with a hot gas purge to regenerate, cooled, and refilled with liquid before returning to service. The drain step must come before heating or the trapped liquid cokes. ADSORB liquid full DRAIN depressure, empty HOT PURGE regenerate COOL REFILL DRAIN THE LIQUID BEFORE HEATING, OR IT COKES

Depressure and drain come before the heating step.

Dryness and Copper Strip

LPG and NGL are treated to a product sales spec. Water and copper corrosion govern, and mercaptan sulfur is held to a low limit. Inlet levels depend on the field and the upstream treating, so the values are typical.

ParameterTypical inlet Required outletUnit
Water50 to 500 1 to 5ppmw
Mercaptan sulfur10 to 200 5 to 10ppmw
Copper strip corrosiontarnished class 1a, no tarnishASTM D130

Product specs are contractual and vary by market. Confirm against the sales specification.

13X, 4A or 3A for Liquid Service

To dry and sweeten the liquid, 13X is used. Its wide pore holds both water and the larger mercaptan molecules. Where only water must come out, a 4A or 3A bed holds more water for the same volume.

The liquid flows down through the bed. Downflow keeps the charge packed. Upflow would lift the beads and grind them to fines. Inert ceramic balls hold the charge at each end. Where the feed carries free water or heavy ends, a guard layer of activated alumina or silica gel, both from Medaad, protects the sieve. Bed design sets the depth and the vessel.

Figure 02 · The copper strip test, treated and untreated
Copper strip corrosion result for untreated and treated LPG A copper strip dipped in untreated LPG tarnishes dark and fails. A strip dipped in treated LPG stays bright and passes at class 1a on the ASTM D130 scale. UNTREATED tarnished, fails TREATED bright, class 1a →

The copper strip test, ASTM D130, is the pass or fail test for corrosive sulfur. A treated product should leave the strip bright, at class 1a.

Swing on a Liquid Full Vessel

The cycle is a thermal swing with a drain step at the start of regeneration. After the drain, the hot gas purge enters at 230 to 290 °C, and the bed is then cooled and refilled with liquid in downflow.

Water and sulfur adsorbed from a dense liquid release heat quickly, so the bed can warm sharply as it loads. The feed rate is set to control this heat of wetting. The regeneration gas must be free of oxygen. Otherwise oxygen and the desorbed sulfur form solid sulfur on the bed.

Liquid Phase Vessels and Treater Charges

In liquid service the distributor and the hold down keep the bed intact through an upset. SorbiTech fabricates liquid phase vessels to specification and supplies the charge for them. Shell, nozzles and internals follow adsorber vessel design.

Request a Quote

Where LPG and NGL Are Treated

Treaters run at the gas plants described under oil and gas processing and on the LPG streams of oil refineries. What shortens a charge, from coke to fines, is covered in service life and dusting.

Related duties

Beds on Liquid Streams

01
Mercaptan and H₂S removal
Polishing the last of the sulfur out of a gas stream to meet the total sulfur spec.
View mercaptan and H₂S removal

LPG and NGL Treater Questions

Are propane, butane and mixed NGL treated the same way?

Yes, with some differences. A lighter liquid flashes more as the pressure changes, so the drain and pressure control are set to the product. A mixed NGL stream carries a wider range of sulfur species than pure propane, which favours the wide pore 13X.

Does caustic washing replace the sieve bed?

No. Caustic washing is the common way to take most of the mercaptans out of LPG, and refrigeration or salt dryers can remove part of the water. The adsorbent bed is the final treat. It reaches a tight spec in one step, with no chemical to handle or dispose of.

Can the same grades treat gas streams?

Yes, in the vapour phase. Those duties are covered under natural gas dehydration and mercaptan and H₂S removal.

Which bead properties matter most in liquid service?

Strength and low fines, because a surge can lift and grind the bed. Attrition loss is measured by ASTM D4058 and written into the order specification with its limit.

How is a charge matched to an installed treater?

The charge is matched to the vessel internals and its actual operating flow. Send the liquid flow, the water and mercaptans in the feed, and the dryness and copper strip specification.

Quote for an LPG or NGL Treater Charge

A liquid phase charge sized to dry the product and remove the mercaptans to its copper strip and dryness spec.

Request a Quote
Contact