Molecular Sieve Solvent Drying

3A and 4A beads take dissolved water out of process and laboratory solvents, in a drum or a packed column.

Find My Solution

Quick Answer

Solvent drying removes dissolved water from process and laboratory solvents with 3A or 4A molecular sieve, chosen so the pore admits water but not the solvent. Water is about 2.6 Å across, while methanol, ethanol and acetonitrile are all wider than 3 Å, so a 3A charge dries nearly every common solvent.

  • 3A and 4A molecular sieve
  • Beads and pellets
  • Batch soak or packed column
  • Crush strength by ASTM D4179
  • Tapped density by ASTM D4164
  • Manufactured by Medaad

Request the TDS Request the SDS

Updated

Taking Water Out of a Solvent

Some reactions are very sensitive to water. In Grignard work, polyurethane work and anything with an isocyanate or an acid chloride, a few hundred parts per million of water in the solvent can change the outcome.

Distillation takes a solvent only as far as its azeotrope. An adsorbent goes further, as a bed on an ethanol column does, because it holds water by size and polarity.

Solvent Molecule Size and Pore Size

A solvent that fits inside the pore competes with water for the same sites. Water capacity collapses, and solvent is lost at every regeneration.

Water is about 2.6 Å across. Methanol, ethanol, acetonitrile and most common solvents are wider than 3 Å, so a 3A charge handles nearly all of them. For solvents too large to enter a 4 Å window as well, 4A is used for its faster uptake.

Figure 01 · Water fits, the solvent does not
3 A WINDOWWATER 2.6 AENTERS, IS HELDETHANOL 4.4 ATOLUENE 5.9 ASTAYS IN SOLUTIONSTAYS IN SOLUTION

Figure 01 · Kinetic diameters are published physical constants. The window figure is the nominal value for the grade.

SolventMoleculeUsual grade
Methanol3.6 angstrom3A
Ethanol4.4 angstrom3A
Acetonitrile4.3 angstrom3A
Tetrahydrofuran5.0 angstrom3A
Toluene5.9 angstrom3A or 4A

Batch Soak or Process Column

Two arrangements cover most of the work. The simplest is to drop beads into the drum or vessel and leave them to stand. For a batch of solvent sitting idle, that is usually enough.

In a packed column the solvent is pumped through a bed. The outlet water figure stays steady, which suits a plant drawing solvent continuously, and the charge can be regenerated in place.

SoakPacked column
Suitsa standing batchcontinuous draw
Outletan averageconsistent
Handlingbeads lifted outregenerated in place
Formbeadsbeads or pellets

Peroxides, Acids and Colour Bodies

Molecular sieve removes water. Peroxides that have built up in an ether are still there afterwards, and so are acids, colour bodies and most dissolved salts.

These need other media, and SorbiTech supplies activated carbon and alumina for them. Using the sieve as a general clean up fouls the charge early.

Reactivating a Spent Charge

A solvent charge can be reused. Heating drives the water off and the beads go back into service. In a laboratory that means an oven. On a plant it means a hot purge stream.

Residue limits how many times this works. Solvent left in the bed bakes onto the bead each time, and after enough cycles the uptake does not recover.

3A and 4A Charges for Drums and Columns

PuraDry 3A, the 3A grade, covers most solvent work. It is supplied as beads for soak duty and as pellets for columns. PuraDry 4A is used for the large solvents in the table above. Bead size depends on the arrangement: a soak needs surface area, a column needs a predictable pressure drop. Grade selection sets out the method.

Where peroxides, acids or colour bodies are present, activated carbon or alumina takes them out ahead of the sieve, so the sieve charge is left for water. A plant drawing solvent all day can run two columns, one drying while the other is reactivated. The dehydration units and adsorber vessel design pages cover that arrangement.

Request a Quote

Related Solvent and Chemical Duties

Questions on Drying Solvents With Molecular Sieve

Why is 4A not used to dry methanol?

Methanol is narrower than the 4 Å opening, so a 4A charge would take it up along with the water and lose capacity to it. The 3 Å opening keeps methanol out.

Which way should a solvent flow through a packed column?

Downflow. A liquid full vessel runs downflow so the beads stay settled and do not grind against each other, which keeps fines out of the dried solvent.

Can one column dry several different solvents?

Solvent held in the bed from one product can come off into the next. A column is usually kept to one solvent, or drained and purged between products.

How is a solvent column reactivated?

The liquid is drained first. A warm purge gas then passes through while the temperature is ramped up, held, and brought back down with cool purge before the column is refilled.

How is the water left in a dried solvent measured?

Karl Fischer titration is the usual method for water in an organic solvent. It reads down to parts per million, which is the range that matters for water sensitive reactions.