Molecular SieveZeolite AdsorbentsBy SorbiTech™
Compressor hall with technicians at work

Molecular Sieve Refrigerant Drying

3A beads in a filter drier core hold the water sealed into a refrigeration circuit, for the life of the core.

Find My Solution

Quick Answer

Refrigerant drying uses molecular sieve in filter drier cores to hold the water sealed into a refrigeration or air conditioning circuit at assembly. A 3A grade is used because water, at about 2.6 Å, fits its 3 Å window while the refrigerant stays out, so the core fills with water and not with refrigerant.

  • 3A molecular sieve, XH grade
  • Beads sized to the core
  • Blended cores with activated alumina
  • Crush strength by ASTM D4179
  • Particle size by ASTM D4513
  • Manufactured by Medaad

Request the TDS Request the SDS

Updated

Water in a Sealed Refrigeration Circuit

A refrigeration circuit is sealed. Any water in it got there at assembly, in the oil, on the pipe walls or through a joint, and it has no way out.

A filter drier deals with that water. It is a small vessel in the liquid line with a fixed charge of desiccant, which takes up the water and keeps it.

Single Use Filter Drier Cores

Most molecular sieve beds are loaded, cleared and loaded again thousands of times. A drier core is never regenerated.

It adsorbs once, slowly, over years, like a packaging desiccant. There is no wear from switching and no thermal ageing. A core that fills up is cut out and replaced.

Figure 01 · Where the drier sits in a sealed loop
COMPRESSORCONDENSERDRIERliquid lineEXPANSIONvalveEVAPORATORNothing enters or leaves. The water the loop was built with is the water the core has to hold.

Figure 01 · A domestic or commercial circuit in outline. Larger plant carries the same four components with more instrumentation around them.

Valve Freezing and Acid Formation

Water causes two kinds of failure. The refrigerant is at its coldest at the expansion valve, so free water freezes there. The valve blocks and the system stops cooling.

The slower failure is chemical. Water, refrigerant and lubricant together form acid. The acid attacks the motor winding insulation and a hermetic compressor burns out. The drier protects the compressor as well as the valve.

What water doesWhereResult
Freezesthe expansion valvethe valve blocks
Forms acidwith oil and refrigerantwinding insulation attacked
Corrodescopper pipeworkdeposits move downstream
Breaks down oilthe lubricant chargesludge in the circuit

Why Refrigerant Driers Use 3A

A refrigerant molecule is far larger than water, but a wide pore still takes it up. A core full of refrigerant has no room left for water. Water is about 2.6 Å across and fits the 3 Å window of a 3A core.

Some refrigerants also break down on contact with the wrong surface, and a 3 Å window keeps them away from it. The XH grades are made for this.

Filter drier coreA swing bed
Cyclesnonethousands
Regenerationneverheat or pressure
Servicecut out and replacedrecharged in place
Failure modefull, or shedding finesattrition and ageing

Bead Strength and Dust in a Drier

Fines from a broken bead leave the drier with the refrigerant. They travel into the valve and the compressor, and the compressor cannot tolerate solids.

So crush strength and low attrition are specified more tightly than capacity. The core also has a filter behind the bed to catch anything that gets through.

Choosing the Core Charge

The charge follows from what the circuit has to hold. Water alone calls for a straight XH charge. Where acid has to be held as well, the core is blended.

Circuit needCore chargeForm
Water held at the liquid linePuraDry XH, a 3A gradebeads sized to the housing
Water and acidblended core, XH with activated aluminabeads sized to the housing
A refrigerant the core has not run ongrade checked before the first fillas above

Bead size is set by the core. It decides both the packing and what the retention screens must hold. Grade selection sets out how it is matched.

XH Beads for Drier Makers and Service

SorbiTech supplies PuraDry XH, the 3A grade made for refrigeration and air conditioning cores, to drier makers filling new cores and to plants that keep their own spares. Blended cores carrying alumina alongside it are supplied as well. Quantities are usually set by the core volume and the annual build.

Request a Quote

Related Sealed Unit Duties

Questions on Filter Drier Desiccant

Why is the filter drier changed whenever a circuit is opened?

Opening the circuit lets in moist air, and the old core may already be close to full. A fresh core takes up the water that came in during the work before it can reach the expansion valve.

Does a 3A core take up the compressor oil?

No. Lubricant molecules are far wider than the 3 Å opening, so the oil passes through the core with the refrigerant. The pore is left free for water.

What does the activated alumina add to a blended core?

Activated alumina takes up acid as well as water. In a blended core it holds the acid formed from water, oil and refrigerant, and the XH beads hold the water.

How is dusting from drier beads checked?

Attrition and abrasion loss is measured by ASTM D4058, which reports the fines made when beads rub together in handling and service. The limit is set in the order specification.

Are XH beads heated before they go into a core?

No heating is needed on the line. The beads are supplied activated in sealed packs, and the water left in them as packed is one of the properties named in the order specification. A nitrogen blanket is a published packing option.

Quote for Filter Drier Beads

Send the bead size, the core volume, the refrigerant and the annual quantity.

Request a Quote
Contact
Email[email protected] Call+971 56 777 3027