Molecular SieveZeolite AdsorbentsBy SorbiTech™
Tall adsorber vessels at an LNG plant

Molecular Sieve LNG Pretreatment

Layered alumina, 13X and 4A dryer beds that dry LNG feed gas and take out mercaptans before liquefaction.

Find My Solution

Quick Answer

LNG pretreatment is the series of units that removes water, acid gas, sulfur, mercury and heavy hydrocarbons from feed gas before liquefaction, so nothing freezes in the cold box. The molecular sieve dryer is the deep drying step. A layered bed of alumina, 13X and 4A takes the water and, on most feeds, the mercaptans too.

  • Molecular sieve 4A and 13X
  • Alumina or silica gel guard layer
  • Inert ceramic ball support
  • Crush strength by ASTM D4179
  • Manufactured by Medaad

Request the TDS Request the SDS

Updated

Pretreatment Before Liquefaction

An LNG plant cools natural gas to about minus 160 °C, where it turns to liquid. At that temperature water, carbon dioxide, heavy hydrocarbons, the aromatic BTX group and mercaptans freeze to ice or wax and block the cold exchanger.

The molecular sieve dryer removes the water. A pipeline dryer only has to stop liquid forming in the line. An LNG dryer has to stop a trace of water freezing in an exchanger near minus 160 °C.

A molecular sieve holds water very strongly at process temperature, which is how it reaches that level.

Position in the Pretreatment Train

Each unit in the train removes a different contaminant. A mercury guard comes early, because mercury attacks the aluminium in the cold exchanger. An amine unit then takes out the bulk carbon dioxide and hydrogen sulfide.

After the amine unit, the sieve sees only the acid gas that is left. Gas that is still sour at the dryer inlet is covered under sour gas dehydration.

Figure 01 · The molecular sieve in the LNG pretreatment train
The molecular sieve dryer in the LNG pretreatment train Feed gas passes down through a line of units: mercury removal, acid gas removal on amine, molecular sieve dehydration, then liquefaction to LNG. The molecular sieve dryer is the deep drying step and reaches below 0.1 ppmv of water while also taking the mercaptans and heavy hydrocarbons. FEED GAS MERCURY REMOVAL guard bed, protects the exchanger ACID GAS REMOVAL amine, takes out CO₂ and H₂S DEHYDRATION molecular sieve dryer WATER TO < 0.1 ppmv + mercaptans, heavy ends LIQUEFACTION cold box, near minus 160 C LNG

A typical line up. Mercury guard first, then the amine unit, then the molecular sieve dryer.

How Dry Must LNG Feed Gas Be?

Each contaminant has a hard limit at the cold box, and each is taken by a different unit.

ContaminantWhy it must go Typical LNG targetTaken by
Water Freezes as ice in the cold exchanger below 0.1 ppmvMolecular sieve, 4A
Carbon dioxide Freezes as solid CO₂ and blocks the passages below 50 ppmvAmine unit upstream
Hydrogen sulfide Corrosion and the product sulfur limit below 4 ppmvAmine unit upstream
Mercaptans, total sulfur Product and pipeline sulfur specification below 30 ppmvMolecular sieve layer, 13X
Heavy hydrocarbons, C5 plus and BTX Freeze and wax at cryogenic temperature C5 plus below 0.1 mol percentMolecular sieve layer, 13X
Mercury Attacks the aluminium exchanger around 0.01 µg per Nm³Guard bed, non regenerable

Targets are industry typical for a pipeline quality feed and vary by licensor. Design against the specification set by your liquefaction licensor.

Alumina, 13X and 4A Layers in One Dryer

On an LNG feed the dryer is almost always a layered bed. Each layer does one job, in the order the gas meets it. Bed design covers the depth and the vessel sizing.

Gas enters at the top and flows down. The guard layer, from Medaad, costs less per unit of water than zeolite and shields the sieve from a liquid slug. The 13X follows because mercaptans and heavier hydrocarbons are too large for 4A.

LayerMedia Job
Guard, top Activated alumina or silica gel Bulk water, and protection from liquid carryover
Middle 13X Mercaptans and heavy hydrocarbons
Polish, bottom 4A Water down below 0.1 ppmv
Ends Inert ceramic ball Hold down at the top, support at the bottom
Figure 02 · The layered LNG dryer bed
Layered molecular sieve bed for LNG pretreatment A single adsorber vessel shown in section. Gas enters the top and flows down through a ceramic hold down layer, an activated alumina or silica gel guard that takes the bulk water, a 13X layer that takes the mercaptans and heavy hydrocarbons, a 4A polishing layer that brings the water below 0.1 ppmv, and a ceramic support layer, leaving the bottom as dry gas. Regeneration gas flows up in the reverse direction. GAS IN DRY GAS OUT REGEN GAS · UPFLOW, HOT CERAMIC HOLD DOWN ALUMINA GUARD bulk water 13X LAYER mercaptans, heavy ends 4A POLISH water < 0.1 ppmv CERAMIC SUPPORT

Section through one dryer vessel. The guard and the 13X layer are sized to the feed. A lean, sweet gas needs less of each.

Regeneration on an LNG Train

The dryers run on a temperature swing. While one vessel dries gas, another is regenerated and cooled. LNG trains usually have three or four vessels, often two drying and one regenerating, because the vessels are large and regeneration takes hours.

A slipstream of dry gas, about a tenth of the feed, is heated and passed up through the vessel. It drives off the water and heavy ends. A cooling pass brings the vessel down before it goes back on line.

StepWhat happens Typical range
Adsorption One or two vessels dry the gas on line about 16 hours per vessel
Heating A heated slipstream of dry gas drives the water and heavy ends off 250 to 300 °C at the inlet

A bed on a large train sees several thousand cycles, so the beads must take thermal cycling without dusting. Regeneration gives the heat and mass balance.

LNG Dryer Packages and Layered Charges

The layers are sized together, since each one sets the load on the next. Where the vessels are not yet contracted, the layers and the vessels can be supplied as one package, built on the TSA dehydration unit design. Molecular sieve dehydration units explains the valves, supports and regeneration loop.

Request a Quote

LNG Plants and Upstream Gas Treating

The wider plant is described under LNG liquefaction plants, and the gas plants that feed it under oil and gas processing. The ways a dryer charge ages are set out in service life and dusting.

Related duties

Beds in the LNG Train

01
Sour gas dehydration
Drying gas that also carries hydrogen sulfide and carbon dioxide, on an acid resistant bed.
View sour gas dehydration

LNG Dryer Questions

Why is the regeneration heat raised slowly?

A fast ramp boils water off the top layers and condenses it on the cooler bed below. That leaches the binder and weakens the beads.

What causes coking on an LNG dryer?

C5 plus and BTX held on the 13X layer can crack during hot regeneration and lay down carbon, which blinds the pores. The heavy hydrocarbon layer is sized for the feed, and the heat is ramped gently.

How does amine carryover harm the bed?

Amine solution or free water from the upstream unit attacks the binder and crushes the top beads. A coalescing filter and knockout between the amine unit and the dryer, and a robust guard layer, protect it.

What is hydrothermal ageing?

Water at regeneration temperature slowly breaks the crystal down, so the deep drying capacity falls cycle by cycle. A slow ramp with a soak, and dry regeneration gas, slow it.

Why must the bed run above the hydrocarbon dew point?

At high pressure a shift in temperature can drop heavy hydrocarbons out as liquid onto the bed. Running above the hydrocarbon dew point, with margin, prevents it.

Can SorbiTech do the sizing without supplying the vessels?

Yes. Process design, sizing and simulation are offered on their own where the vessels are already contracted.

Quote for an LNG Dryer Charge

The guard, 13X and 4A layers are sized together for water below 0.1 ppmv and for the mercaptans and heavy ends in the feed.

Request a Quote
Contact
Email[email protected] Call+971 56 777 3027