Molecular Sieve CO₂ Removal From Natural Gas
A 13X polishing bed that takes the last carbon dioxide out of natural gas ahead of a cryogenic plant.
Quick Answer
CO₂ removal with molecular sieve takes the last of the carbon dioxide out of natural gas after an amine unit or a membrane, ahead of cryogenic processing. A 13X bed holds carbon dioxide at very low levels and is cleared with a heated purge on a thermal swing, so no dry ice forms in the cold exchanger.
- Molecular sieve 13X
- 4A bulk layer option
- Inert ceramic ball support
- Crush strength by ASTM D4179
- Manufactured by Medaad
Updated
Taking Carbon Dioxide Out of Gas
Carbon dioxide lowers the heating value of natural gas, and with water it forms an acid that corrodes the line. Ahead of a cryogenic plant it also freezes to dry ice and blocks the cold exchanger. The freezing temperature rises with carbon dioxide content and pressure, so a cryogenic feed must be taken to a very low level.
Most of the carbon dioxide comes out first in an amine unit, a membrane or a cryogenic step. These cost less for large tonnages. A molecular sieve bed then takes the rest below 50 ppmv, the figure a liquefaction or deep recovery plant needs. The strong field in the 13X pore holds carbon dioxide at these low levels.
A pipeline allows a percent or two of carbon dioxide, and a membrane or amine unit usually meets that alone. A cryogenic plant allows a few tens of ppm, and the sieve makes that last cut. On a small or offshore plant, a compact unit with no solvent can be worth more than the lowest running cost. There the sieve can take a larger share.
Polishing Bed Position Before the Cold Box
The polishing bed is one of the last units before the cold box. The gas reaches it with most of the carbon dioxide gone and the water already out. The bed must sit after the dryer. Drying is its own duty, natural gas dehydration, and on a cold feed it is part of LNG pretreatment.
The sieve is the last carbon dioxide step, after the bulk removal and after the dryer.
Outlet Carbon Dioxide Limits
The outlet is set by what follows the bed. A cryogenic plant needs the carbon dioxide below 50 ppmv so no dry ice forms in the cold exchanger. The inlet depends entirely on how much the bulk step left behind, so the values are typical.
| Parameter | Typical inlet | Required outlet | Unit |
|---|---|---|---|
| Carbon dioxide, after bulk removal | 0.2 to 3 | under 50 | percent in, ppmv out |
| Water at the carbon dioxide bed | dry | already below 0.1 | ppmv |
The outlet is set by the liquefaction or recovery licensor. Confirm it against the process specification.
13X Grade and the Effect of Water
A molecular sieve holds water hardest, then carbon dioxide. Light hydrocarbons are held only weakly.
So a trace of water that reaches the bed takes the sites the carbon dioxide needs and pushes carbon dioxide back off. Carbon dioxide then breaks through well before the calculated end of the cycle.
13X is the grade. Its wide pore and strong field give it the highest carbon dioxide capacity in the range. Where inlet carbon dioxide is higher, a layer of 4A below the 13X takes the bulk and the 13X polishes. The bed rests on inert ceramic balls. Bed design sets the split and the depth.
The bars show relative strength of hold only. Water is held first, then carbon dioxide, then the hydrocarbon.
Polishing Units, Bulk Units and Recharges
The bulk step ahead of the bed can be the group’s gas sweetening unit. The polisher itself is a thermal swing vessel set laid out like the twin tower TSA dehydration unit. Where an installed bed no longer meets its outlet figure, the new charge and its layer split are set from the carbon dioxide the bulk stage now passes forward. Send that figure with the vessel size.
Gas Plants That Use a Polishing Bed
Polishing beds sit in the plants described under LNG liquefaction plants and oil and gas processing. Causes of lost capacity on any regenerated bed are covered in service life and dusting.
Beds in the Same Train
CO₂ Polishing Bed Questions
How is a 13X carbon dioxide bed regenerated?
On a thermal swing. A heated slipstream of dry gas, 200 to 315 °C at the inlet, drives the carbon dioxide off, and the same gas unheated cools the bed. The crystal degrades if the bed is held above about 325 °C.
Why can the regeneration cooler freeze?
The spent regeneration gas carries the desorbed carbon dioxide and any water from the bed. Cooled too fast, both can freeze in the cooler, so the cooling rate and the separator conditions are set to prevent it.
Can amine carryover damage the sieve?
Yes. Amine aerosol carried over from the bulk unit fouls the sieve. A coalescing filter between the amine unit and the bed stops it.
Do heavier hydrocarbons compete with carbon dioxide on 13X?
They do. Heavier hydrocarbons can take sites on the 13X, break through and freeze downstream. A guard layer for the heavies and the right grade split handle them.
Why does a partly regenerated bed lose capacity?
A bed not stripped fully back keeps residual carbon dioxide, and its working capacity falls each cycle. Enough regeneration temperature and gas flow each cycle prevents it.
Quote for a 13X CO₂ Polishing Bed
A 13X bed to polish carbon dioxide below 50 ppmv for a cryogenic feed, after the bulk removal and the dryer.
Request the TDS and SDS
Name the grade, 13X or 4A, and the documents you need for the polishing bed.