Molecular Sieve Electrolyser Hydrogen Drying
A twin tower 3A dryer that removes stack water from electrolyser hydrogen before compression and storage.
Quick Answer
Electrolyser hydrogen drying removes the water that leaves the stack with the gas, using a twin tower molecular sieve 3A dryer. Hydrogen is barely held and passes through, while a heated purge clears the off line tower. The dried gas then goes to compression or storage.
- Molecular sieve 3A
- PuraDry 3A beads and pellets
- 4A for moderate dew points
- Packing density by ASTM D4164
- Manufactured by Medaad
Updated
Hydrogen That Leaves the Stack Wet
Hydrogen made by splitting water leaves the stack saturated with water. Gas from an alkaline or PEM stack is already pure by composition. It carries as much moisture as its temperature and pressure allow.
A knockout drum removes the liquid. The water vapour that remains harms compressors, storage vessels and fuel cells.
Electrolytic Hydrogen Versus Reformer Hydrogen
Hydrogen purification is pressure swing adsorption on reformer gas. There the bed holds back carbon dioxide, methane, carbon monoxide and nitrogen, and the hydrogen passes.
Electrolytic hydrogen contains none of these. Water is the only thing to remove. The unit is a twin tower dryer with heated regeneration.
Figure 01 · Arrangement is typical. Not every train has a recombiner, and the cooler position varies with the design.
3 Å Pore and Hydrogen
Hydrogen is smaller than the 3 Å window. It is also non polar, so a zeolite of any pore size barely holds it.
The narrow 3A pore is chosen because it keeps other molecules out. Its capacity goes to water, and little else comes off the bed on regeneration.
Dew Point Before Compression
The end use sets the dew point. Hydrogen going to a compressor and storage cylinders is dried deeply. Water that condenses at pressure stays in the cylinder until it is emptied.
The figures below are typical for the duty. They are not a design basis.
| Parameter | Typical range | Unit |
|---|---|---|
| Pressure dew point | −40 to −70 | °C |
| Regeneration | heated purge | no pressure swing |
| Bed arrangement | twin tower | one on line |
| Working charge | 3A | beads or pellets |
| What leaves the stack | Fate in the dryer | Note |
|---|---|---|
| Hydrogen | passes | non polar, barely held |
| Water vapour | held | the only target |
| Oxygen traces | passes | burned at the recombiner |
Recombiner Heat and the Bed Behind It
Many electrolyser trains have a catalytic recombiner that burns residual oxygen to water. It adds moisture, so it sits ahead of the dryer.
Gas leaves the recombiner hot. A bed holds less water from warm gas than from cool gas. The cooler between the two is part of the dryer design.
Grades for Green Hydrogen Dryers
PuraDry 3A, the 3A grade, is the working charge. It comes as beads, and as pellets where the vessel suits them. For a clean stream with a moderate dew point target, 4A is also used.
Both are made by Medaad, the group manufacturer. Grade selection explains how the choice is made.
Twin Tower Units for Electrolyser Projects
The dryer follows the twin tower TSA dehydration unit layout. Valves, supports and the heater loop are described under molecular sieve dehydration units.
Hydrogen Projects and Related Pages
Electrolyser plants sit within hydrogen and carbon capture. The heating step is worked out as in regeneration temperature and cycle. The grade itself is described under 3A molecular sieve.
Electrolyser Hydrogen Dryer Questions
Why does a running hydrogen dryer lose its dew point?
Check the regeneration temperature first. It is the usual cause: a bed that is not heated enough does not give up its water.
Does fuel cell hydrogen need a deeper dew point?
Yes. Fuel cell service needs a lower dew point than hydrogen sent to compression and storage.
Does an alkaline stack need different treatment from a PEM stack?
The drying duty is the same, since both deliver hydrogen saturated with water. Electrolyte mist from the stack is removed by a filter before the dryer.
Can the charge be supplied for vessels already ordered?
Yes. SorbiTech supplies the charge alone for vessels already ordered, or sizes the dryer and supplies a fabricated twin tower unit.
What is needed to size an electrolyser dryer?
The hydrogen output of the stack, the pressure at the dryer and the dew point the end use requires.
Quote for an Electrolyser Hydrogen Dryer
The dryer is sized to the stack output. The regeneration heat can come from what the site already has. Send the hydrogen output and the pressure.
Request the TDS and SDS
Name the grade and form, beads or pellets, and the documents you need for the hydrogen dryer.