Molecular SieveZeolite AdsorbentsBy SorbiTech™
Molecular sieve 5A beads

Molecular Sieve Types and How to Choose Between Them

A step by step method to pick 3A, 4A, 5A or 13X from the composition of the stream.

Related Solutions

Quick Answer

To choose a molecular sieve grade, start from the molecule that must stay in the stream, then pick the narrowest grade that still admits the contaminant. Pore width settles what can enter the crystal, and strength of hold, side reactions and regeneration decide between grades that both fit.

  • Grades 3A, 4A, 5A and 13X
  • Beads and pellets
  • 8 x 12 and 4 x 8 mesh
  • Manufactured by Medaad

Request the TDS Request the SDS

Engineering GuideUpdated

Four types cover most gas and liquid duties, the 3A, 4A, 5A and 13X grades. Their nominal openings are about 3, 4, 5 and 10 Å. The method below turns a stream composition into a grade, then checks the choice against chemistry, bed layout and particle form.

Kinetic Diameter and Pore Entry

Kinetic diameter is the smallest width a molecule presents as it tries to pass through an opening. The length of the molecule does not count. That is why long straight chains can enter a pore that turns away a compact branched one. The basic idea of a crystal that sorts by size is explained in what a molecular sieve is.

Figure 01 sets the four nominal openings against seven common molecules on one scale.

Figure 01 · Nominal pore openings of the four grades and the kinetic diameters of seven common molecules, drawn to one scale
NOMINAL PORE OPENING, ONE SCALE3 Å3ATYPE A4 Å4ATYPE A5 Å5ATYPE A10 Å13XTYPE XKINETIC DIAMETER, SAME SCALEWATER2.6 ÅCO₂3.3 ÅH₂S3.6 ÅMETHANE3.8 ÅPROPANE4.3 ÅISOBUTANE5.0 ÅBENZENE5.9 Å

Openings are the nominal values that name the grades. The free aperture of the crystal is smaller, about 3.8 Å for 4A, 4.3 Å for 5A and 8.1 Å for 13X. A molecule close to the limit, such as isobutane on 5A, is held back.

The table adds further molecules that often decide a selection. Values are approximate textbook figures, and molecules close to a limit enter slowly or not at all. 13X holds nitrogen strongly, which makes it useful in oxygen generation.

MoleculeApproximate kinetic diameterNarrowest grade that usually takes it up
Ammonia2.6 Å3A
Hydrogen2.9 ÅEnters every grade but is held only weakly
Methanol3.6 Å4A
Sulfur dioxide3.6 Å4A
Nitrogen3.6 Å5A, with 13X holding more
Carbon monoxide3.8 Å5A
Ethylene3.9 Å4A
Normal butane and longer straight chains4.3 Å5A

Six Step Grade Selection Method

The steps run from size, which rules grades in or out, to the secondary checks that choose between the grades left.

  1. List every component of the stream with its concentration and kinetic diameter. Mark the product that must stay and each species that must come out.
  2. Set the upper limit. The opening should turn the product away, unless the product is a molecule the sieve barely holds, such as methane in natural gas dehydration.
  3. Set the lower limit. The opening must admit every contaminant that the bed has to remove.
  4. Compare strength of hold. Polar molecules are held harder than nonpolar ones, and water hardest of all, so water pushes weaker species down the bed.
  5. Check side reactions at both process and regeneration temperature, as described in the next section.
  6. Choose the particle form and size against the allowable pressure drop and the regeneration the plant can provide.

Steps 2 and 3 often leave one grade. 3A molecular sieve dries reactive or polar streams because almost nothing else enters. 4A molecular sieve is the general drying grade where the product is not adsorbed. 5A molecular sieve separates straight chains from branched ones in normal paraffin separation. Where two grades remain, the side by side view in 3A against 4A, 5A and 13X helps settle it.

Side Reactions and Co Adsorption

A grade that fits by size can still be the wrong choice. Three cases come up often.

Sour gas carries H₂S and CO₂ together. On a sieve that admits both, the two can react to form carbonyl sulfide (COS) and water. The COS is weakly held and slips into the product, where it later concentrates in the propane fraction. Drying with 3A keeps both acid gases out of the crystal, and low COS formulations exist for wider grades. The duty is covered in sour gas dehydration and the removal of sulfur species in mercaptan and H₂S removal.

Olefins, dienes and acetylenes that enter the pores can polymerise when the bed is heated for regeneration. The residue stays as coke and blocks capacity. Reactive feeds in petrochemical olefin purification therefore favour the narrowest opening that still takes water.

Methanol, often injected upstream to stop hydrates, enters 4A and competes with water for space. It also adds load to the regeneration step. 3A turns methanol away, which is one reason it is chosen for solvent drying and alcohol duties. Where methanol itself must come out, the case belongs with oxygenate removal.

Layered Beds With Two or Three Adsorbents

A stream with several contaminants of different sizes often needs more than one adsorbent. Each layer is placed where its species arrives. Water is the most strongly held component, so the drying layer always sits at the inlet.

Each layer sees only what the one above lets through, and one regeneration serves the whole vessel. Every layer must therefore accept the same heat or pressure swing. Layer depths come from the dehydration bed design and the internals that separate them from adsorber vessel design.

Beads or Pellets and Particle Size

Molecular sieve is formed as round beads or as extruded pellets. For the same size, beads give a much lower pressure drop than pellets, because gas flows more easily around spheres. Beads also pack evenly and resist wear at the contact points.

Particle size is a compromise. Smaller particles take up water faster, which shortens the mass transfer zone, the band of bed where drying is still under way. They also raise the pressure drop for the same gas velocity. Larger particles do the reverse. A common answer in tall dryers is a compound bed, with larger particles in the upper part and smaller ones near the outlet. The bead and pellet forms offered for each grade are listed on the grade pages, and the way they are made in manufacturing.

Worked Example for Cracked Gas Drying

The table follows the six steps for a common petrochemical duty, the dryer that protects the cold section of an ethylene plant.

StepFinding
StreamCracked gas with hydrogen, methane, ethylene, propylene, butadiene, traces of acetylene and saturated water
Must stayEthylene and the heavier olefins
Must come outWater, down to the low ppmv level the cold section needs
Size limitWater enters 3A, ethylene does not, and 4A would take up ethylene
Chemistry checkOlefins and dienes held in the pores would polymerise during heating
Grade chosen3A, which holds water and keeps the olefins out
FormBeads, to keep pressure drop low on a large gas flow

The same reasoning extends to propylene and butene streams, as described in cracked gas and olefin drying. A narrow grade also means less hydrocarbon is held in the pores, so the bed warms less when fresh feed first meets it after regeneration.

Data Needed for a Grade Recommendation

A grade can only be chosen against a stated stream. The list below covers what usually decides it.

  • Full composition, including trace species such as methanol, oxygen, H₂S, COS and dienes
  • Flow, pressure and temperature at the dryer inlet
  • Water content at the inlet and the outlet target
  • Regeneration gas, the temperature available and the intended step time
  • Any liquid, glycol or amine that may reach the bed
  • For an existing unit, the vessel size and the present charge

Switching grade in a working dryer follows the sequence in loading and replacement, and the new charge needs the heating schedule from regeneration temperature and cycle. The application engineering behind a recommendation is described under the SorbiTech team.

Questions on Choosing a Grade

What is kinetic diameter in a molecular sieve?

It is the smallest effective width of a molecule, worked out from how gas molecules collide. A molecule can pass a pore window only if this width is close to or below the opening. Because molecules flex and the window vibrates, the cut is not perfectly sharp. A molecule just above the limit may still enter, but very slowly.

Can a wider grade always replace a narrower one?

No. A wider opening admits more species, and that can cause harm. 13X in place of 3A on an olefin dryer would adsorb the olefin, raise heat on start up and build coke during regeneration. A wider grade can replace a narrower one only where nothing extra that enters is reactive, valuable or competing for space.

When is 13X preferred over 4A?

13X is preferred when the species to remove is too large for 4A, such as ethyl and heavier mercaptans in LPG and NGL treating, or when CO₂ must come out at low concentration. Its larger cages also hold more of such species per kilogram. For plain drying of a sweet gas, 4A usually does the job with a higher bulk density, as in refrigerant drying circuits.

How do I choose the bead size?

Begin with the allowable pressure drop and the vessel diameter. Large flows in wide vessels can accept smaller beads and gain a shorter drying front. Low pressure duties and tall narrow vessels favour larger beads. Where both matter, a compound bed of two sizes balances the two. Bed design calculations confirm the final split.

How do I switch grade in an existing dryer?

Confirm first that the new grade fits the regeneration heater, the step time and the vessel volume. The bulk density may differ, so the mass per bed changes. Then unload, inspect the support, load the new charge and give it a full first regeneration before it goes on line. Record the pressure drop at start so later changes can be tracked.

Request a Grade Recommendation and Quote

A grade question is answered from the stream. Send SorbiTech the main components and trace species, marking what must come out and what must stay. Add the inlet pressure, temperature and water content, the outlet target and the regeneration method. Mention olefins, dienes, methanol or sulfur compounds, since each can change the grade.

Request a Quote
Contact
Email[email protected] Call+971 56 777 3027