Natural gas dehydration with molecular sieve dries gas to pipeline dew point, or deeper for cryogenic plants, in thermal swing beds of 4A. Pipeline sales gas is held to about 4 to 7 lb of water per MMscf, while a cryogenic feed is dried below 0.1 ppmv, deeper than a glycol contactor reaches.
- 4A molecular sieve
- 13X topping layer
- Beads and pellets
- Crush strength by ASTM D4179
- Tapped density by ASTM D4164
- Manufactured by Medaad
Updated
Water Limits for Sales Gas and Cryogenic Feed
Natural gas leaves a field saturated with water. A transmission contract limits how much may stay in it, because water and hydrocarbon form hydrate at pressure and a hydrate plug stops the line. A cryogenic plant needs the gas drier still, since any water left freezes in the cold box.
| Parameter | Typical inlet | Required outlet | Unit |
|---|---|---|---|
| Water content, cryogenic feed | saturated | under 0.1 | ppmv |
| Water content, pipeline sales gas | saturated | 4 to 7 | lb per MMscf |
| Water dew point, cryogenic feed | at line conditions | below minus 100 | °C |
| Water dew point, sales gas | at line conditions | below coldest line temperature | °C |
When Is Molecular Sieve Used Instead of Glycol?
The outlet water figure decides it. A glycol contactor removes the bulk of the water for much less energy and handles ordinary transmission gas well. A molecular sieve bed is used where the contract or the process needs a dew point below what a contactor reaches, which means every cryogenic front end. SorbiTech Group supplies both.
Figure 01 · Where a contactor hands the gas over to an adsorption bed. Bands show normal practice.
Choosing the Grade and the Layers
The working charge is PuraDry 4A, as beads or as PuraDry 4A-P pellets. 4A holds methane only weakly and water far more tightly, so the bed fills with water and the gas passes. Other layers are added for what else the feed carries.
| Feed | Bed | Reason |
|---|---|---|
| Sweet gas | 4A alone | Water is the only duty |
| High water load | alumina or silica gel over 4A | The guard takes the bulk water first |
| CO₂ or mercaptans present | 13X layer above 4A | Treats them in the same vessel |
| Still sour at the dryer | low COS grade | See sour gas dehydration |
Medaad, the group manufacturer, makes every grade in the table. Bulk supply detail is on Medaad.
Adsorber Cycle and Bed Arrangement
A dryer runs as a pair of vessels on a thermal swing. One dries while the other is heated, cooled and held on standby, and the unit swaps them before the wet front reaches the outlet. Feed enters at the top and dry gas leaves at the bottom, which keeps the most heavily loaded zone at the inlet.
Section through one adsorber, drawn with a 13X layer above the 4A.
The charge sits between ceramic support layers that carry its weight and keep beads off the outlet. Bed design sets the depth from the gas rate and the cycle.
Regeneration Envelope
A slipstream of dry gas is heated and passed up through the bed, against the drying direction, so water leaves by the face that collected it. The wet gas is cooled, drops its water in a separator and is boosted back to inlet pressure.
| Step | What happens | Typical range |
|---|---|---|
| Heating | Hot dry gas drives the water off the bed | 280 to 315 °C at the inlet |
| Cooling | Unheated dry gas brings the bed back down | to near the adsorption temperature |
| Damage limit | The crystal structure degrades if the bed is held too hot | above about 325 °C |
A full cycle commonly runs four to twelve hours. The slipstream takes ten to twenty percent of throughput and is not sold. Regeneration sets out the balance.
Common Causes of Dryer Failure
When a bed dries well for a year and then misses specification, the cause is usually something the design did not allow for. Most often it is liquid.
| Condition | Mechanism | Prevention |
|---|---|---|
| Liquid carryover | A slug of water, hydrocarbon condensate or carried over glycol reaches the bed, crushes the top beads and makes fines that migrate to the outlet | Free water knockout on the feed, with an inlet separator and coalescing filter immediately upstream |
| Hydrothermal ageing | Steam at regeneration temperature slowly dealuminates the crystal, and equilibrium water capacity falls cycle by cycle | Limit the water loading, control the regeneration gas moisture, and never heat a fully wet bed hard |
| Coking of the 13X guard | Heavy hydrocarbons taken up on the guard layer polymerise and lay down carbon during hot regeneration, blinding the pores | Size the 13X guard for the real heavies present, and hold the regeneration temperature inside the band |
| Flow channelling | Segregated or loose loading lets gas find a low resistance path, the front tilts, and breakthrough arrives before the calculated cycle end | Dense or sock loading, level the top of each layer, and screen the media for fines before charging |
| Support layer failure | A degraded ceramic layer lets the bed settle unevenly or lift on regeneration, and the flat flow front is lost | Inspect and replace the support and hold down ball at every change out |
Charge Only or Complete Dryer Package
Scope can be the charge alone for an existing tower, the process design and sizing, or a complete twin tower TSA dehydration unit. On a new dryer the bed and the vessel are designed together, as the dehydration units and adsorber vessel design pages show. Where the scope includes a vessel or a complete unit, PuraSpecs takes the mechanical design and fabrication.
Gas dryers sit in gas plants ahead of a transmission line, in front of LNG liquefaction and cryogenic NGL recovery, and on storage withdrawal. The sector views are oil and gas processing and LNG liquefaction plants.
Beds That Sit Near a Gas Dryer
Questions on Natural Gas Dryers
How fast does a gas dryer charge lose capacity?
In most NGL plant service the sieve loses about 5 to 15 percent of its capacity a year, mainly to fouling and carbon. It lasts longer with light feed and regeneration gas, good inlet filtration and long adsorption cycles.
How is the remaining capacity of a dryer bed checked?
By breakthrough testing. A portable hygrometer on the dry outlet of the oldest bed records the time from the start of adsorption to a steady rise in dew point. Repeated on each bed, the results show when a change out is due.
Can a gas dryer run with three beds?
Yes. Two beds dry in parallel while the third regenerates. Splitting the flow lowers the pressure drop and the compression energy, and it allows smaller pellets to be used.
Does a new charge need regeneration before it goes on stream?
Yes. A pre service regeneration heats the sieve above 250 °C in a flowing gas stream to make it fully active. The bed is then cooled with dry gas to about 40 to 50 °C above ambient before the feed is let in.
How fine must the liquid removal ahead of a dryer be?
Fine enough that no droplets reach the sieve. One published gas dryer specification places microscrubbers ahead of the towers that remove all liquid particles above 5 microns. The figure is set for each plant.