Molecular SieveZeolite AdsorbentsBy SorbiTech™
Molecular sieve 3A beads on a steel bench

3A vs 4A Molecular Sieve, and Where 5A and 13X Fit

How pore width separates the four common molecular sieve grades, and which duty each one suits.

Related Solutions

Quick Answer

Pore size decides between 3A, 4A, 5A and 13X molecular sieve. Use 3A to dry a stream whose product molecules must stay out of the pore, 4A for general drying that may also take CO₂ and H₂S, 5A for straight chain paraffins and hydrogen purification, and 13X for CO₂, mercaptans and air cleanup.

  • Type A and type X zeolite
  • Beads and pellets
  • 8 x 12 and 4 x 8 mesh
  • Manufactured by Medaad

Request the TDS Request the SDS

ComparisonUpdated

A and X are two different synthetic crystal types. The number gives a rough window width in angstroms. The sections below compare the grades in pairs, as the question usually comes up on a plant.

Pore Width of 3A, 4A, 5A and 13X

The three A grades share one crystal framework. Their windows differ because the exchanged cation that sits in the window changes, and each cation blocks a different part of the opening. That gives nominal openings of about 3 Å, 4 Å and 5 Å. 13X uses the X crystal, a separate framework with larger cages and a window of about 10 Å.

Because the windows step up in size, each grade holds every molecule the narrower grades hold, plus those its own window admits. Water, at about 2.6 Å, fits all four. Figure 01 draws the four openings at one scale so the jump from 5A to 13X is easy to see.

Figure 01 · The four pore openings at one scale
3AABOUT 3 ÅTYPE A4AABOUT 4 ÅTYPE A5AABOUT 5 ÅTYPE A13XABOUT 10 ÅTYPE X

Each circle is drawn in proportion to the nominal opening of its grade. The dark dot in each opening is a water molecule at the same scale, which fits all four.

Water capacity, bulk density and the heat needed for regeneration all differ a little between grades. The window is what decides the choice. The four molecular sieve grades are therefore picked by asking which molecules must enter and which must not.

What Each Grade Holds and Keeps Out

The table lists typical behaviour for each grade type. Borderline molecules, such as ethane on 3A or ethylene on 4A, depend on temperature, pressure and contact time, so the limits are less sharp than the table shows.

GradeHoldsKeeps outTypical duties
3A, about 3 ÅWater and ammoniaEthane and larger, including methanol, ethanol, ethylene and propyleneCracked gas and olefin drying, ethanol dehydration, insulating glass
4A, about 4 ÅWater, CO₂, H₂S, SO₂, methanol, ethane, ethylene and propylenePropane and largerNatural gas dehydration, refrigerant drying, solvent drying
5A, about 5 ÅAll of the above plus straight chain paraffins and alcoholsBranched molecules and rings of four carbons and largerNormal paraffin separation, hydrogen purification
13X, about 10 ÅAll of the above plus larger polar molecules such as heavier mercaptansOnly very bulky moleculesAir prepurification, mercaptan and H₂S removal, oxygen generation

3A or 4A for Drying

Both grades dry gases and liquids to a very low water content. The difference is what else enters the pore. Ethanol is about 4.4 Å across, so 3A turns it away while 4A lets it in. The same is true for methanol and the light olefins.

In an olefin stream this matters for two reasons. First, every molecule of product held in the bed is product taken from the stream. Second, olefins held on a hot, active surface can join together into polymer, a sticky oily residue that plants call green oil, and later into coke. Both coat the crystals and cut capacity. 3A keeps the olefins outside the cages, so it is the usual charge in petrochemical olefin purification. Some 3A products are also formulated to limit carbonyl sulfide forming when CO₂ and H₂S pass through together.

4A suits streams where taking a little CO₂, H₂S or methanol along with the water does no harm, or is even wanted. Plain natural gas, compressed air drying and many liquid hydrocarbons fall in this group. Where the gas is sour, sour gas dehydration weighs the extra sulfur uptake of 4A against the narrower window of 3A.

5A for Paraffin Separation and Hydrogen Purification

The step from 4 Å to 5 Å is small, and it changes what the bed holds. A straight chain paraffin such as normal butane or normal hexane is a thin molecule and passes through the 5A window. A branched or ring molecule of the same carbon number is wider and stays out. 4A takes neither. Refiners use this to pull normal paraffins out of naphtha and kerosene, either to raise the octane of the branched remainder or to recover pure straight chain feed for detergents. Those streams are part of the work in oil refineries.

Hydrogen purification by pressure swing uses several layers in one vessel. Alumina or silica gel at the inlet takes water, activated carbon takes CO₂ and methane, and a zeolite layer at the product end holds carbon monoxide and nitrogen, the gases that slip through the carbon. 5A is a common choice for that last layer. Units serving hydrogen and carbon capture plants use this final layer.

5A has a limit in sulfur service. It takes hydrogen sulfide and the smallest mercaptans well, but it does not adsorb mercaptans larger than ethyl mercaptan. Those need 13X.

13X for CO₂, Mercaptans and Air Purification

Both 4A and 13X take CO₂ and H₂S alongside water. The wide 13X window adds the whole mercaptan range and other larger polar molecules. That makes it the charge for LPG and NGL treating, where propyl and butyl mercaptans must leave a liquid product, and for CO₂ removal from natural gas at trace levels.

Air is the other large 13X duty. Plants for air separation and industrial gases compress the air and chill it to around 8 °C before the sieve. The bed then holds water, CO₂ and hydrocarbons such as acetylene, which would otherwise freeze or collect in the cold box. The adsorption step ends before CO₂ breaks through.

13X carries more water per kilogram than 4A. It is also lighter, so a vessel of fixed volume holds fewer kilograms. When water is the only target and no larger molecule needs to be caught, the narrower grade is usually the simpler choice. LNG pretreatment often uses both, each in its own layer.

Heat of Adsorption and Regeneration by Grade

Water releases a similar, large amount of heat on every grade, because the bond comes from the charged framework. The grades differ in what else is held and how gently it must be released.

  • 3A is regenerated at the low end, typically about 200 to 230 °C. Its narrowed window and the olefin streams it serves both favour a cooler purge. It also loses capacity faster as the feed warms, so feed is kept cool.
  • 4A, 5A and 13X are typically regenerated at about 280 to 315 °C in gas dehydration.
  • A 13X bed loaded with mercaptans is often held near 180 to 200 °C for an hour or two first. Mercaptans start to break down near 220 °C, so the hold lets them leave intact before the bed is taken hotter.
  • CO₂, nitrogen and carbon monoxide are held more loosely than water. That is why 5A and 13X also work in pressure swing units, where a drop in pressure releases them without heating.

Heating, hold and cooling steps are covered in the regeneration temperature and cycle guide. Overheating, liquid water and repeated thermal shock age every grade, as described under service life and dusting. The heaters and switching valves that run these cycles are shown inside a molecular sieve dehydration unit.

Choosing a Grade in Five Steps

Most grade questions can be settled in a few steps.

  1. List what must come out, such as water, CO₂, H₂S or mercaptans.
  2. Name the largest molecule that must stay in the product, such as ethanol, ethylene or a branched paraffin.
  3. Pick the narrowest grade that admits every contaminant and still turns that molecule away.
  4. Check feed temperature, regeneration heat available and any reactive species against that grade.
  5. If one grade cannot cover everything, consider two grades in layers.

The guide to molecular sieve types and grade selection works through mixed feeds in more depth. Layer depths and particle sizes follow dehydration bed design, and the vessel around them is covered in adsorber vessel design. Newcomers may want to start with what a molecular sieve is and how it sorts molecules.

Questions on 3A, 4A, 5A and 13X Grades

Can 4A replace 3A?

Sometimes, but only after checking the stream. In a plain gas with no alcohols or olefins, both grades dry well. In cracked gas, ethylene, propylene or alcohol service, 4A takes product into its pores, gives off more heat in the bed and is more prone to fouling. Swapping grades in an existing vessel also changes regeneration settings, so the whole cycle needs review.

Can 13X be used just for drying?

Yes. 13X is a strong desiccant and holds water to very low levels. It is often chosen for drying when CO₂ or sulfur compounds must leave in the same bed. For water alone, a narrower grade usually holds fewer hydrocarbons along with the water and packs more kilograms into the same vessel, so the comparison is worth making.

What do the letters A and X mean?

They name two synthetic crystal types. Type A has a compact framework, and its window can be set to 3, 4 or 5 angstroms by changing the exchanged cation. Type X has a more open framework with larger cages. The digits in 3A, 4A and 5A track the window, while the 13 in 13X is a product name rather than a pore size.

Can two grades share one vessel?

Yes, and layered beds are common. A typical pattern puts the drying grade at the inlet, where water loads first, and 13X below it for mercaptans or CO₂. The layers share one regeneration cycle, so the temperature has to suit both. Separate loading of each layer is planned as in loading and replacement.

Which molecular sieve grade is used for ethanol?

3A. Distillation stops near 95 percent ethanol by weight because water and ethanol form an azeotrope, a mixture that boils without changing composition. A 3A bed takes the remaining water from the vapour by pressure swing, giving fuel grade ethanol. This route is standard in biofuel and biogas plants.

Request a Quote for 3A, 4A, 5A or 13X

Send SorbiTech the stream composition, gas or liquid, and the species that must come out with their inlet levels. Name the molecules that must stay in the product and the outlet target. Add flow, operating pressure and temperature, the regeneration heat available, and the grade now installed, if any, so the comparison starts from the plant as it runs.

Request a Quote
Contact
Email[email protected] Call+971 56 777 3027