Each material has its own duties, and many dryers load both in one vessel, with alumina at the wet inlet and sieve at the dry outlet. The sections below set out what each material is, where each one fits on its own, and how designers combine the two.
Structure of Activated Alumina and Molecular Sieve
Activated alumina is a porous aluminium oxide. It is made by heating aluminium hydroxide until water leaves the solid, which opens a network of pores in many sizes. Water and other polar molecules cling to the large internal surface. Because the pores vary in size, alumina adsorbs by polarity. It does not sort molecules by size.
Molecular sieve is a crystalline zeolite. Its pores are cages joined by windows of one fixed width, and the grade sets that width. 3A molecular sieve admits water and turns away almost every hydrocarbon. 4A molecular sieve also takes up CO₂ and H₂S. How a crystal sorts molecules by size is covered in what a molecular sieve is, and the differences between the grades in 3A against 4A, 5A and 13X.
SorbiTech Group supplies both materials, and both are made by Medaad.
Activated Alumina and Molecular Sieve Property Table
The table gives typical values for each product class from published design practice. Single batches and single grades differ, so each figure is a guide only.
| Property | Activated alumina | Molecular sieve |
|---|---|---|
| Outlet dew point reach | About minus 40 °C (minus 40 °F) or lower in compressed air dryers | About minus 70 °C (minus 94 °F) in compressed air, and near minus 100 °C in gas plants |
| Capacity at high humidity | High near saturation, falling as the gas gets drier | Lower near saturation, but almost constant across the humidity range |
| Liquid water tolerance | The most tolerant of the common desiccants | Built for water vapour, so a separator keeps liquid off the charge |
| Crush strength and attrition | High crush strength that limits dusting | Firm beads that dust mainly when the bed moves or meets liquid |
| Regeneration temperature | About 160 to 220 °C | About 200 to 315 °C |
| Typical uses | Plant and instrument air, guard layers, removal of acid traces | Feed to cryogenic units, deep dew point air, selective drying of olefins and ethanol |
The capacity row explains most of the pattern. Alumina holds more water when the gas is close to saturation, so it works hardest where the feed is wettest. The sieve still holds water at very low partial pressure, which means a low concentration of water in the gas. This is why it is used for the final drying.
Activated Alumina for Moderate Dew Points and Wet Feeds
Most plant air and instrument air needs a dew point that alumina reaches on its own. In a heatless dryer, one tower dries while the other is purged with a share of the dry air at low pressure. Alumina gives up its water easily, so this pressure swing alone keeps it working. Plant duties of this kind are described under compressed air drying, and vehicle systems under air brake drying.
Alumina also suits feeds that are hard on a desiccant. It accepts droplets of liquid water without breaking up, and it takes up acid traces such as hydrogen chloride. It stays stable when amine or caustic is carried over from upstream treating. These traits make it the usual protective layer in front of a more sensitive adsorbent, and a common choice in chemical process plants that dry wet or acidic gas streams.
Molecular Sieve for Cryogenic Feeds and Deep Dew Points
A gas cooled far below ambient must be almost free of water, or ice and hydrates block the cold equipment. Molecular sieve is the standard adsorbent for LNG pretreatment, where outlet water is held to a fraction of one ppmv ahead of the cold box. The same need drives drying ahead of helium recovery and throughout LNG liquefaction plants.
The sieve also holds water when the partial pressure is very low. That covers gas that is already fairly dry but must go drier, as in electrolyser hydrogen drying and captured CO₂ drying.
A third reason is selectivity. A 3A charge dries cracked gas and olefins while the olefin stays in the stream, and it dries ethanol while the ethanol passes through. Alumina has no size cut, so it cannot sort molecules in this way.
Layered Beds With Activated Alumina Above the Sieve
Gas usually flows down through a dryer during adsorption, so the top of the bed meets the wettest and dirtiest gas. Figure 01 shows the usual layout. A layer of alumina sits on top and takes bulk water, droplets and acid traces. The sieve below then works on clean vapour and sets the final dew point.
Gas flows down. The alumina layer meets the wet feed first, and the sieve under it holds the remaining water. Layer depths depend on the duty and are not drawn to scale.
In natural gas dehydration the alumina layer is typically 0.3 m deep or more, above a deep sieve charge. The arrangement is standard across oil and gas processing wherever the inlet may carry amine, glycol or chlorides. In air prepurification for air separation plants, alumina takes most of the water and a 13X molecular sieve layer behind it takes CO₂.
Each material stays a distinct layer, separated where needed by a thin band of inert balls. Layer depths come out of the bed design calculation, and the vessel internals that hold them are covered under adsorber vessel design.
Regeneration Heat and Cycle Length
Alumina releases its water at a lower temperature, so a heated alumina dryer needs less heater duty per kilogram of water. Its easy release is also why purge alone can regenerate it in short cycles of minutes.
The sieve holds water more tightly and needs hotter gas to strip it. Heated sieve beds usually run longer adsorption steps of several hours, with a heating and cooling sequence in between. In a layered bed the heating step is set for the sieve, and the alumina regenerates in the same pass. Heating and hold times are explained in the guide to regeneration temperature and cycle.
Every cycle ages both materials a little. Hot water vapour, liquid carryover and heavy hydrocarbons that turn to coke all reduce capacity over the years. The causes and their signs are set out in service life and dusting, and the complete twin tower package in dehydration units.
Choosing the Desiccant for a Compressed Air Dryer
Start from the pressure dew point the users need, which is the dew point measured at line pressure. A target no deeper than the alumina figure in the table suits an all alumina charge in a heatless dryer. Targets of minus 70 °C and below point to a sieve charge, either alone or as an outlet layer under alumina. Between the two, a compound bed lets the alumina carry the bulk water while the sieve sharpens the drying front.
Then check the inlet. A warm inlet carries more water per cubic metre, which favours more alumina at the top. Oil mist or liquid slugs from the compressor call for good filtration ahead of either material. Finally, match the charge to the regeneration the dryer can provide, purge only or heated.
Silica gel is also used for this duty, and that choice is compared in molecular sieve against silica gel. When an existing dryer is recharged with a new split, the steps in loading and replacement apply to both layers.