Molecular Sieve CNG Drying
A hard 4A bead that dries gas for compression to vehicle fuel and stands up to station pressure cycling.
Quick Answer
CNG drying removes water from natural gas before it is compressed to vehicle fuel, so nothing condenses or freezes at the dispenser or in the vehicle cylinder. A molecular sieve 4A bed takes the gas to a deep water dew point, on a hard bead that stands up to the pressure cycling of a fuelling station.
- Molecular sieve 4A
- Hard spherical beads
- Crush strength by ASTM D4179
- Attrition by ASTM D4058
- Manufactured by Medaad
Updated
Drying Gas for Vehicle Fuelling
Compressed natural gas is pipeline gas compressed to around 250 bar and stored for vehicles. Water that causes no trouble in the pipeline does once the gas is compressed. At the dispenser the gas expands and cools sharply. Any water in it condenses and freezes, blocks the valve and can stop a fill.
A molecular sieve bed takes that water out before compression. The pores hold the water and the methane passes. The bed is regenerated with heat and used again.
A glycol unit dries gas to a pipeline sales spec. Refrigeration removes part of the water and is often used ahead of the bed. Activated alumina or silica gel, both from Medaad, can predry a wet feed. The sieve then takes the gas to the CNG dew point.
Nozzle Temperature and Fill Rate
A pipeline water spec is set by the coldest point on the line. At a CNG station the coldest point is the dispenser nozzle. A fast fill from 250 bar can take the gas well below zero there. The dew point is set so that no water condenses or freezes even at that temperature.
Fill rate matters. A fast fill at a public station gets colder than a slow overnight fill at a depot, so it needs a lower dew point. A rich gas can also drop heavy hydrocarbons as it is compressed and cooled, and the bed has to cope with them.
The gas is coldest where it expands into the vehicle, so CNG needs a lower dew point than sales gas.
Dew Point at Storage Pressure
The target is a water dew point below the coldest temperature at the dispenser. Station standards fix the figure. The values below are typical. Storage pressure sets both the dryer design and how cold the gas gets on the fill.
| Parameter | Typical value | Unit |
|---|---|---|
| Water dew point at line pressure | minus 40 to minus 60 | °C |
| Storage pressure | 200 to 250 | bar |
| Inlet water | water saturated | at line conditions |
Dew point targets follow the national CNG standard. Confirm the one that applies. Bead sizes are listed under 4A.
4A Grade and Crush Strength
4A is the grade. Its pore takes water and keeps out methane and the heavier hydrocarbons. Where carbon dioxide must also come out, a layer of 13X goes above the 4A.
Bead strength matters as much as the grade. A station cycles its beds often. Each cycle swings from storage pressure down to a low regeneration pressure and back. A weak extruded pellet cracks and powders. The dust raises the pressure drop and carries downstream. The duty needs a hard spherical bead with high crush strength. Inert ceramic balls hold the charge, and bed design sets the depth.
Rapid pressure swings are the main mechanical load on a CNG dryer bead.
Station Dryer Skids and 4A Charges
Within the group, PuraSpecs designs and fabricates station dryer skids, to a customer specification or from the duty. A station dryer follows the twin tower TSA dehydration unit, and the internals are described under molecular sieve dehydration units.
Fuel Gas for Fleets
Gas fuelled buses and trucks belong to automotive and transport systems, and the gas itself to oil and gas processing. Brake air on the same vehicles is dried under air brake drying.
Related Compressed Gas Duties
CNG Station Dryer Questions
Do CNG stations use heated or heatless dryers?
Most run a thermal swing. One bed dries while another is heated with a slipstream of dry gas, typically 200 to 290 °C at the inlet, and then cooled. Small stations sometimes use a heatless swing, regenerated with a slip of dry gas at low pressure.
Does compressor oil affect the dryer?
Yes. Oil from the compressor coats the beads and blinds the pores. A coalescing filter between the compressor and the dryer keeps it off the bed.
What happens to heavy hydrocarbons on a CNG bed?
Heavy ends taken up on the sieve can coke during regeneration and cost capacity. Keeping 4A as the grade and holding the regeneration temperature in band limits this.
Why does loading matter so much on a station dryer?
Loose or settled loading lets gas find a path through the bed, and breakthrough comes early. Dense loading, a level bed and an outlet dust filter prevent it. Loading and replacement covers the method.
Can a charge be matched to an existing station dryer?
Yes. For a station in service, the charge is matched to the existing vessel and cycle. Send the gas flow, the storage pressure and the dew point needed at the dispenser.
Quote for a CNG Station Dryer Charge
A 4A charge on a hard bead for the pressure cycling, sized to the dew point the dispenser needs.