Molecular SieveZeolite AdsorbentsBy SorbiTech™
Bus depot with a fleet in service

Molecular Sieve for Automotive and Transport Components

Hard drying beads for brake cartridges, filter drier cores and the dryers at CNG fuelling stations.

Request Technical Consultation

Quick Answer

Molecular sieve for automotive and transport is the drying bead in brake cartridges, air conditioning filter driers and CNG station dryers. Most parts carry 4A or 3A beads chosen for hardness. A CNG station dryer takes gas stored at 200 to 250 bar down to a dew point of minus 40 to minus 60 °C.

  • Zeolite 4A and 3A
  • Media made by Medaad
  • Crush strength to ASTM D4179
  • Attrition to ASTM D4058
  • Particle size to ASTM D4513

Request the TDS Request the SDS

In road and rail vehicles the sieve is a small part inside a larger assembly. The air brake cartridge, the air conditioning core and the CNG station dryer all hold zeolite beads. Each charge takes water out of air, refrigerant or natural gas. It does so before that water reaches valves, compressors or fuel cylinders, where it would corrode or freeze.

Each part only dries. The vehicle sets the rest of the specification. The beads take road shock, engine heat and compressor oil, and many are sealed in at assembly and never renewed.

Bead sizes are listed on the 4A and 3A grade pages.

CNG Station Dryers and Component Fills

The station dryer is the one complete unit in this sector. SorbiTech Group builds it as a skid on the pattern of the twin tower TSA dehydration unit. Depot air for tools and brake testing can run on a heatless desiccant air dryer. Cartridges and drier cores are component fills. For those, SorbiTech supplies beads to the builders and rebuilders, including a dedicated Air Brake grade. Station vessels and skids come from PuraSpecs, the group's equipment company.

GasmainVehicledispenser1CoalescingfilterProcess unit2Sievedryer4A media3StationcompressorProcess unit4StorageProcess unit
Treatment train · Gas from the main through a 4A station dryer and compression to the vehicle dispenser

Shock, Dust, Heat and Oil in Truck, Bus and Rail Service

Vibration and road shock rub bead against bead and against the housing for the life of the part. That wear makes dust. Fines from worn beads travel downstream and can lodge in valve seats. Crush strength, size spread and dust level are the first properties a component maker agrees with the supplier.

Temperature also swings. A part may see a winter cold start in the morning and engine bay or compressor heat by midday. Compressor oil is the third problem. Where no coalescer stands upstream, oil vapour and mist from the compressor coat the bead surface. A coated bead takes up water more slowly. Tolerance of heat and oil belongs in the specification alongside strength.

A drier core or a packed part is filled once and sealed. It is never regenerated or topped up, so the charge loaded at assembly must last the life of the part. The packed volume is fixed at the drawing stage. Electronics and spares shipped in sealed packs face the same limit, covered under packaged desiccant.

Brake Cartridges, Filter Drier Cores and Station Dryers

Three components carry most of the sieve used in the sector. Two travel on the vehicle and one stands at the depot or forecourt. The brake cartridge cycles wet and dry many times a day. The air conditioning core holds its charge for years without regeneration. The station dryer is a fixed vessel, regenerated on site.

Brake Systems on Road and Rail Fleets

On trucks, buses, coaches and rail vehicles the cartridge sits between the compressor and the first reservoir. It purges each time the governor cuts out. The beads therefore cycle wet and dry throughout their service, and every cycle adds a little wear. Cartridge design, fill and purge are covered under air brake drying. Water is about 2.6 Å across and passes the 4 Å window of the cartridge bead.

Fleets change cartridges on a schedule, and rebuilders refill used housings with fresh beads. Rail units add long idle spells and underframes open to spray. Water at the reservoir drain is often the first sign a fleet notices. Depot air for tools, tyres and brake testing belongs to compressed air drying.

Air Conditioning Filter Drier Core

The core sits in the liquid line after the condenser. It is fitted at assembly and replaced whenever the circuit is opened. Hoses let some moisture in over the years, and the core rides engine bay heat and road shock throughout. The refrigerant decides which adsorbent the core may hold. Some cores blend in activated alumina from Medaad to take up acid as well. Core types and refrigerants are covered under refrigerant drying.

CNG Station Dryer

At a CNG fuelling station the dryer is a skid beside the compressor. Its feed comes from the gas main or a depot supply. A coalescing filter keeps lubricant off the bed. A bus depot filling overnight loads the dryer differently from a public forecourt serving fast fills all day. The gas analysis and the local climate set the rest of the duty, described under CNG drying.

Figure 01 · Drying steps in a brake system, an air conditioning circuit and a CNG station
AIR BRAKE SYSTEMCOMPRESSORAIR DRYERMOLECULAR SIEVEBRAKE VALVESAIR CONDITIONING CIRCUITCONDENSERFILTER DRIERMOLECULAR SIEVETO EXPANSION VALVECNG FUELLING STATIONCOMPRESSORGAS DRYERMOLECULAR SIEVETO STORAGE AND DISPENSER

Each row runs left to right in the direction of flow. The blue box is the step that holds the molecular sieve.

Related Transport and Fuel Gas Topics

How beads wear and shed dust over a service life is set out in service life and dusting. Filling a housing or a station vessel is covered under loading and replacement. Pipeline gas ahead of a fuelling station is dried to a sales figure, described under natural gas dehydration and the oil and gas processing industry.

Questions on Molecular Sieve for Automotive and Transport

Why does CNG need a lower dew point than pipeline gas?

The gas expands and cools sharply at the dispenser nozzle. Any water in it condenses and freezes, blocks the valve and can stop a fill. The dew point is set below the coldest nozzle temperature.

Does a public fast fill station need a different dew point from a depot?

Yes. A fast fill at a public station takes the gas colder than a slow overnight fill at a depot, so it needs a lower dew point.

What changes in a station dryer when carbon dioxide must also come out?

A layer of 13X goes above the 4A. The 4A pore takes water and keeps out methane and the heavier hydrocarbons.

Does the purge on an air brake cartridge clear compressor oil?

No. Oil mist coats the bead and the purge does not remove it. A coalescing stage ahead of the desiccant does, so most cartridges carry one in the same housing.

Why do air conditioning filter driers use a 3A core?

Water, at about 2.6 Å, fits the 3 Å window while the refrigerant stays out. A core filled with refrigerant would have no room left for water.

What harm does water do in a sealed air conditioning circuit besides freezing?

Water, refrigerant and lubricant together form acid. The acid attacks the motor winding insulation, and a hermetic compressor can burn out.

Quote for Cartridge, Drier Core and Station Beads

SorbiTech supplies Medaad beads for brake cartridges and drier cores. For CNG stations the group also offers a twin tower TSA dehydration unit. Send the housing drawing or fill volume, the bead size and the annual quantity. Add the refrigerant, or the gas analysis and fill pattern. A fleet that finds water at the drain should add the service interval, climate and compressor condition.

Request a Quote
Contact
Email[email protected] Call+971 56 777 3027