Molecular SieveZeolite AdsorbentsBy SorbiTech™
Row of blue adsorber towers at a refinery

Molecular Sieve Oxygenate Removal

A 13X bed holds methanol, MTBE and dimethyl ether out of hydrocarbon feeds bound for acid catalysts.

Find My Solution

Quick Answer

Oxygenate removal takes methanol, MTBE and dimethyl ether out of hydrocarbon streams with 13X molecular sieve before they reach an acid catalyst. The wide 13X pore admits these polar molecules and holds them, while the bulk hydrocarbon is held only weakly and passes through as product.

  • 13X molecular sieve
  • Type X zeolite
  • Beads and pellets
  • 1/16 and 1/8 inch pellets
  • Attrition by ASTM D4058
  • Manufactured by Medaad

Request the TDS Request the SDS

Updated

Oxygenates Left in a Hydrocarbon Stream

Streams leaving an ether unit carry traces of its chemistry. Unreacted methanol, the ether product, and dimethyl ether formed as a by product all travel on in the raffinate.

They are present at parts per million. That is enough to harm the acid catalysts in the units downstream.

Why Oxygenate Beds Use 13X

Cracked gas drying uses a narrow pore to keep the olefin out of the cage. Oxygenate removal needs the molecules to get in.

Oxygenates are larger than water, and the bed must hold a lot of them. Capacity and affinity decide the grade, and that points to the widest pore.

Figure 01 · What a 13X bed holds, in order
HELD MOST STRONGLYWATERMETHANOLMTBE AND DMEHYDROCARBONPASSES THROUGHThe order follows how polar each molecule is. The bar lengths show rank, not capacity.

Figure 01 · The order is a ranking. Actual loadings depend on the grade, the temperature and what else is in the stream.

Oxygenate removalCracked gas drying
The grade doesholds the speciesshuts the species out
Pore wantedthe widestthe narrowest
Working grade13X3A
Limit on the bedcapacitywhat reacts inside it

Polarity and the Order of Adsorption

A hydrocarbon is nonpolar, so a zeolite holds it only weakly. An oxygenate carries an oxygen atom and with it a dipole, and the cations in the framework pull on that.

A 13X bed in a hydrocarbon stream lets the bulk pass and collects the few polar molecules. Water is more polar still and is held hardest, so a wet stream fills the bed with water before it takes any oxygenate. The 13X window opens to about 10 Å, wide enough for methanol at about 3.6 Å and for the larger ether molecules.

Effect on Acid Catalysts Downstream

The downstream unit sets the limit. Alkylation, polymerisation and isomerisation units all run acid catalysts, and an oxygenate neutralises acid sites directly.

Part of the lost activity never comes back. That is why the adsorbent bed is placed in front of the reactor.

Downstream unitCatalystWhy it matters
Alkylationacidoxygenates neutralise sites
Polymerisationacidactivity falls, some of it for good
Isomerisationacid functiontemperature has to be raised
Etherificationacid resinrecycle carries them back

Regenerating an Oxygenate Bed

Heat drives oxygenates off, as it does water, but each species leaves at its own rate. A cycle set for water leaves some of them behind.

The heavier species then build up a little each cycle until the working capacity falls short. Set the regeneration profile for the species actually in the stream.

Matching the Bed to the Stream

13X APG, a 13X grade, is the working charge, as beads and as 13X APG-P pellets. Its pore takes every oxygenate found in a refinery stream, so one grade covers methanol and the ethers. What else the stream carries decides the layers around it.

Stream conditionBedWhy
Dry, oxygenates only13X APG aloneone grade for all species
Wet as welldrying layer, then 13Xkeeps 13X for the oxygenates
Heavy ends presentguard layer in frontheavies crack to carbon when heated
Deep bed, tight pressure drop13X APG-P pelletscloser size spread

Grade selection sets out how deep the drying layer must be.

Layered Vessels and Turnaround Recharges

The layers share one vessel, resting on graded ceramic support balls. The bed runs on a thermal swing, the same pattern as the twin tower TSA dehydration unit, and adsorber vessel design covers the internals.

Oxygenate beds are recharged at refinery turnaround, in a vessel and cycle that already exist. If a bed has been falling short of its run length, check the regeneration profile and the water load before changing the grade.

Request a Quote

Related Feed Treating Duties

Questions on Oxygenate Removal Beds

Why can a fresh 13X bed heat up when olefin feed is introduced?

13X takes up olefins as well, and the heat released can raise the bed temperature sharply when olefin feed first meets a freshly regenerated bed, above all in liquid service. Suppliers describe preloading the bed with a low olefin gas before the feed is lined up.

What gas should be used to regenerate an oxygenate bed?

A dry gas free of oxygen, such as residue gas. Oxygen in the purge speeds the coking of anything left on the beads. The inlet temperature is ramped up, held for the soak and then brought down again.

Does the 13X bed also take sulfur compounds?

Yes. 13X also holds hydrogen sulfide and the mercaptans, and they compete with the oxygenates for capacity. Name every sulfur species in the analysis so the bed is sized for the total load.

What else shortens the life of a 13X oxygenate charge?

Glycol and amine carried over from an upstream unit coat the beads and weaken the binder. Liquid water that reaches a hot bed attacks the crystal and the binder, so a separator upstream keeps liquid off the charge.

Are oxygenate beds run on liquid or gas streams?

Both. C3 and C4 feeds to alkylation and polymerisation units are often treated as liquids, and lighter streams as gas. The phase changes the start up procedure and the size form chosen for the bed.

Quote for an Oxygenate Removal Bed

Methanol and MTBE behave differently on the bed, so name each oxygenate in the stream. Send the analysis and the unit downstream.

Request a Quote
Contact
Email[email protected] Call+971 56 777 3027