Quality Assurance

4A Molecular Sieve
Manufactured by
Medaad, group manufacturer
Countries served
40+ worldwide
Forms
Beads and pellets
Documentation
4A Molecular Sieve for Drying Gases and Liquids
SorbiTech Group 4A molecular sieve is a Type A zeolite with a pore of about 4 Å. Alongside water it holds carbon dioxide, hydrogen sulfide and ammonia, which makes it the general purpose drying grade. It holds methane only weakly, so a 4A bed dries natural gas without taking up the gas itself.
Propane, butane, the aromatics and the heavier hydrocarbons are too wide for the 4 Å opening and stay in the gas. The crystal is bound with clay, formed into beads and pellets and fired to activate it. It is the grade most molecular sieve dryers run.
Available Mesh Sizes
| Mesh Size | Particle Diameter | Shapes |
|---|---|---|
| 8 x 12 mesh | 1.6 to 2.6 mm | Beads (spheres) Pellets (extrudates) |
| 4 x 8 mesh | 2.5 to 5.0 mm |
How 4A Removes Water
Water is the molecule 4A holds hardest. Taking it up releases heat, typically about 4,200 kJ for every kilogram of water. The same strong bond keeps the water on the sieve in warm gas, and it is why the bed needs a hot purge to give the water back.
A 4A bed does not fill evenly. Water loads at the inlet first, and the wet zone moves down the bed as a front with dry adsorbent still ahead of it. The outlet stays dry until the front reaches the bottom, so the cycle switches towers before that point.
Regeneration of a 4A Bed
4A gives up its water when it is heated. The hot purge, dry product gas or a dry inert gas, runs the opposite way to the drying flow, so the water leaves by the end where it came in. The purge typically enters at 200 to 315 °C, and the bed is kept below about 325 °C so the crystal is not damaged.
Bring the heat up steadily, because liquid water that reaches hot beads damages them. The bed is then cooled to line temperature before the tower goes back into service. These temperatures are typical for the grade type and are not published product data.
Layering with Activated Alumina
On a wet feed, activated alumina and 4A often share one vessel in two layers. The alumina on top takes the bulk of the water. The 4A underneath takes the gas down to the dew point the process needs. The sieve then carries a lighter load and needs less heat to clear.
SorbiTech Group supplies both media. Most molecular sieve dehydration units run on 4A, with a regeneration heater, a cooler and switching valves around two or more beds.
Why Choose SorbiTech Group
Worldwide Supply
In Stock, Fast Delivery
Technical Support
Supply and Engineering Support for 4A
SorbiTech Group supplies 4A molecular sieve for new dryers and for the recharge of units already in service, from a single change out to a complete first fill, in drum or big bag packing to suit the site.
Our application engineers select the grade, bead size and bed arrangement for your system. The selection is based on your gas composition, flow, operating pressure, inlet water content and the dew point you need. Where the scope goes beyond the media, the group also designs and supplies the adsorber vessels and complete dryer units.
Share your operating data with us to receive a recommendation for your plant and a quotation.
4A Applications in Gas, Air and Solvent Drying
How long does a 4A charge last in a natural gas dryer?
Many charges in gas processing run several years between change outs. Life is longer with a lean, clean feed and gentle regeneration, and shorter with rich, wet or contaminated feed and frequent upsets. The unit's own breakthrough tests give the only reliable forecast.
Can 4A run in a heatless air dryer?
Yes. A heatless pressure swing dryer can use a 4A charge, with dry purge air stripping the water at low pressure. Short cycles keep the water held in each step small, so the bed never loads deeply.
How long is one 4A adsorption step?
In gas plants it is usually several hours, and many dryers switch on a fixed timer. Some end the step on a moisture analyser reading or a bed temperature profile. As a charge ages, the same step time leaves a smaller margin before breakthrough.
Why does a 4A bed have to cool before it goes back on line?
A hot bed holds far less water than a cold one. The first gas through it would leave wetter than specified until the bed cooled itself, and the drying front would already sit part way down the bed.
Why does the pressure drop across a 4A bed rise?
The open space between beads shrinks. Fines from broken beads, caked lumps after refluxing, or coke can fill it, and a blocked support screen has the same effect. A slow rise usually means wear, while a sudden step points to a liquid event or a failed internal.