The Disciplines Behind Molecular Sieve Application Engineering
Four roles answer a molecular sieve duty: the enquiry contact, process and chemistry, systems design and project execution.
Quick Answer
Molecular sieve application engineering at SorbiTech Group covers four roles: the enquiry contact, process and chemistry, mechanical and systems design at PuraSpecs, and project execution at FireBag. SorbiTech, the parent company, is the commercial and technical contact for all of them, so one enquiry reaches every discipline a duty needs.
- Grade selection for 3A, 4A, 5A and 13X
- Media by Medaad
- Systems by PuraSpecs
- EPC by FireBag
Within SorbiTech Group, a grade or chemistry question goes to the process side, which works with Medaad. A vessel or unit question goes to PuraSpecs. A question on site work goes to FireBag.
How a Question Reaches the Right Role
Every route starts with SorbiTech through the enquiry form. The form asks what the enquiry concerns: grade and supply, an engineering question, a complete unit, or documents. That choice shows which role is needed first. A short note on the plant and the problem is enough to start. Drawings and process data sheets can follow once the duty is clear.
One question can lead to another. A grade question can lead to a vessel question, and a vessel question to site work. The roles then work from the same duty data. Data sheets are requested through the same form.
Production is described under manufacturing, and the specification framework under quality and specification. The duty pages in applications show where the sieve sits in a plant. Natural gas dehydration is one example. Reading the matching duty page first helps frame the enquiry.
Application Engineering Roles
Each role covers one part of an adsorption duty. Not every enquiry needs every role. A replacement charge of a known grade may need only the first two. A new dryer unit may draw on all four.
Enquiry Contact at SorbiTech
This role identifies the duty: what is being removed, from which stream, and to what level. Missing data such as composition, pressure, temperature and flow is requested at this stage. The quotation comes from SorbiTech as the commercial contact. It holds the specification agreed for the order.
Process and Chemistry
Process and chemistry covers the adsorbent itself. The first question is which zeolite type fits the molecule to be held. The next are the bead or pellet form and the regeneration the duty allows. This discipline draws on Medaad, the group company that manufactures the media. Background sits in the guides to sieve types and regeneration temperature. Grade choice depends on pore width, about 3 Å for 3A, 4 Å for 4A, 5 Å for 5A and 10 Å for 13X. A cycle review looks at a purge of typically 200 to 315 °C, kept below about 325 °C.
Mechanical and Systems Design at PuraSpecs
PuraSpecs is the group company for mechanical systems design and fabrication. Its engineers handle the vessel and the unit around the media. Typical subjects are adsorber vessel internals, flow direction, regeneration heaters, coolers, separators and the skid that carries them. A duty that needs a complete dehydration unit reaches this discipline. The group's twin tower TSA dehydration unit is a published example.
Project Execution at FireBag
FireBag is the group company for EPC and field execution. This role applies where the order covers more than supply. That can include engineering, procurement, construction and work at the plant. The scope is set in the order documents. A media change out on a running plant falls to this role where the order includes it. So does a new unit on a new site.
Related Guide and Unit Pages
| Page | What It Covers |
|---|---|
| Types and grade selection | The method behind a grade recommendation |
| Dehydration bed design | How a dryer bed is sized zone by zone |
| Dehydration units | The packaged unit around a molecular sieve charge |
| Applications | Every process duty, grouped by type |
Questions on Application Engineering
Can SorbiTech review a bed that is losing capacity?
Yes. Send the outlet dew point trend, the time to breakthrough, the pressure drop record and the regeneration temperatures. The process side compares them with the design basis. The usual causes are set out in service life and dusting.
Does application engineering cover heatless air dryers as well as gas plants?
Yes. The same roles handle short cycle pressure swing dryers and heated thermal swing units. The heatless desiccant air dryer is a published group package.
Is a site visit part of application engineering?
Only where the order includes it. Field execution sits with FireBag, and its scope is written into the order documents.
Who answers questions about vessel internals and heaters?
PuraSpecs engineers. Adsorber internals, flow direction, regeneration heaters, coolers and separators belong to the unit around the media, which is their discipline.
Can a replacement charge be a different grade from the one in service?
It can, after a check. The process side reviews the pore width needed, the regeneration temperature available, the bulk density and the pressure drop before a new grade is proposed for the vessel.
Request Application Engineering Support
Send the duty to SorbiTech with the stream composition, pressure, temperature and flow. State what must be removed and the outlet level the plant needs. If a charge is being replaced, name the grade in service and the vessel dimensions. For a complete unit, add the site conditions and the scope wanted from the group. Process, mechanical or project roles join as the duty requires.