Stream by Stream Molecular Sieve for Oil Refineries
Dryers, treaters and separation beds for the refinery streams that feed sensitive catalysts, acids and products.
Quick Answer
Molecular sieve for oil refineries is the zeolite adsorbent used on the few refinery streams that carry a tight limit. It dries isomerisation and alkylation feeds, treats LPG, extracts normal paraffins from kerosene and recovers hydrogen by pressure swing. A 13X treater typically leaves LPG with 1 to 5 ppmw water.
- Zeolite 5A and 13X
- Media made by Medaad
- Crush strength to ASTM D4179
- Attrition to ASTM D4058
- LPG copper strip to ASTM D130
A fuels refinery runs most of its streams with no adsorbent at all. A few streams are different. They feed a unit whose catalyst, acid or product specification is sensitive to traces of water, sulfur or oxygenates. Molecular sieve for refining sits on those streams, as a dryer, a treater or a separation bed.
The duties fall into two groups. On the fuels side, the sieve dries naphtha and alkylation feeds, treats LPG and extracts kerosene paraffins. In the hydrogen network, it recovers clean hydrogen from reformer net gas and off gas.
Paraffin extraction and hydrogen PSA use 5A, and oxygenate guard beds use 13X.
Refinery Hydrogen and Gas Treating Systems
SorbiTech Group builds the complete units that carry the sieve on refinery service. The hydrogen PSA purification package takes reformer net gas and hydroprocessing off gas. The gas sweetening unit removes the bulk acid gas ahead of a polishing bed. Feed dryers follow the twin tower TSA dehydration unit. Vessels and skids come from PuraSpecs, the group's equipment company.
Fuel Streams and Refinery Hydrogen Recovery
The fuels side moves liquid and gas cuts to conversion units, blending and sales. The hydrogen network carries hydrogen from the units that make it to the units that use it.
The Fuels Side
Light naphtha and its makeup hydrogen are dried before a chlorided isomerisation catalyst. Water strips chloride from that catalyst. The olefin and isobutane feed to the alkylation unit is dried because water dilutes the acid. Raffinate from the ether unit can carry methanol and ethers toward the same acid. A guard bed for oxygenate removal takes them out first.
LPG from the gas plant leaves the caustic wash still carrying water, hydrogen sulfide and some mercaptans. A sieve treater polishes it before storage and sales, a duty covered under LPG treating. On hydrotreated kerosene the sieve is used for separation. Its straight chain paraffins can be drawn off as detergent feedstock. The rest of the cut returns to the fuel pool. A treated product should leave the copper strip bright, at class 1a. The 5 Å pore of 5A admits the straight chain paraffins end on.
The Hydrogen Network
The catalytic reformer makes hydrogen as a byproduct of upgrading heavy naphtha. Hydrotreaters and hydrocrackers consume it, and their purge streams return hydrogen rich off gas. Reformer net gas and that off gas can both pass to a pressure swing adsorption unit. The adsorbent there holds back methane, carbon oxides and heavier hydrocarbons. Clean hydrogen returns to hydroprocessing, and the unit itself is described under hydrogen purification. Pressure swing units are reported to deliver hydrogen at purities up to 99.9999 percent.
Off gas that is not sent to hydrogen recovery goes through the amine absorber to the fuel gas header. After amine treatment it may still hold residual hydrogen sulfide and mercaptans. A sulfur polishing bed on that line removes the remaining traces before the gas reaches them.
From Light Naphtha to Refinery Off Gas
| Stream | Unit it feeds | What the sieve takes out | Duty |
|---|---|---|---|
| Light naphtha and makeup hydrogen | Isomerisation unit | Water, which strips chloride from the catalyst | Isomerisation feed drying |
| Butylene and propylene cut with isobutane | Alkylation unit | Water and polar traces that dilute the acid | Alkylation feed drying |
| Hydrotreated kerosene | Normal paraffin extraction unit | Straight chain paraffins, recovered as the extract | Normal paraffin separation |
| Gas plant LPG after the caustic wash | LPG storage and sales | Water, hydrogen sulfide and leftover mercaptans | LPG treating |
| Sour refinery gas after the amine absorber | Fuel gas header and gas users | Residual hydrogen sulfide and mercaptans | Sulfur polishing |
| Reformer net gas and hydrogen rich off gas | Hydrogen PSA, then the hydrotreaters | Methane, carbon oxides and light hydrocarbons | Hydrogen purification |
| Raffinate from the MTBE or ether unit | Alkylation unit | Methanol and ethers that consume acid | Oxygenate removal |
Blue boxes are adsorption steps and light boxes are process units. LPG, refinery gas and ether raffinate treating sit on gas plant outlets and are not drawn.
Normal Paraffin Extraction From Kerosene
The extraction unit draws hydrotreated kerosene from the rundown. The feed is already low in sulfur, but it is still dried before it reaches the sieve. The zeolite pore admits straight chain molecules and turns away branched and ring molecules. A desorbent then carries the held paraffins out of the bed as the extract. The cycle is set out in full under normal paraffin separation.
The extract goes to detergent alkylate and chlorinated paraffin plants. The raffinate returns to the jet or diesel pool. A light naphtha version of the same process works on a lighter cut. It sends its raffinate to the reformer and its straight chains to petrochemicals as cracker feed.
An extraction unit is specified on the feed, the extract and the raffinate. Extract purity is agreed with the detergent buyer.
Related Refinery Duties and Grades
The full liquid phase cycle for propane and butane is under LPG and NGL treating. Bed sizing for feed dryers is set out in dehydration bed design. The grade pages for 5A and 13X list sizes and forms. Gas plants upstream of the refinery are covered under oil and gas processing.
Molecular Sieve in Refinery Service: Common Questions
Does a sieve treater replace the caustic wash on LPG?
No. The caustic wash removes most of the mercaptans. The sieve bed is the final treat. It reaches a tight water and sulfur figure in one step, with no chemical to handle or dispose of.
Which grade removes methanol and ethers ahead of alkylation?
13X. Its window opens to about 10 Å, wide enough for methanol and the larger ether molecules. A wet stream gets a drying layer in front so the 13X is not used up on water.
How is sulfur handled when a polishing bed is regenerated?
Heating releases a small, concentrated stream of hydrogen sulfide and mercaptans. It is cooled and routed to sulfur recovery or back to the amine system, so it is not vented.
Why must a kerosene feed be dried before paraffin extraction?
Water enters a 5 Å opening easily and is held harder than any hydrocarbon. A wet feed fills the pores with water and the separation stops.
Which layer sets hydrogen purity in a refinery PSA unit?
The 5A layer, placed last in the bed. It holds the carbon monoxide and nitrogen. Activated carbon takes the bulk carbon dioxide and methane first, and 13X polishes the carbon dioxide left.
Quote for Refinery Treaters, Dryers and PSA
SorbiTech supplies zeolite adsorbents made by Medaad for refinery treaters, dryers and separation units. The group also builds a hydrogen PSA purification package. Name the stream and the unit it feeds. Give the contaminants measured and the charge now installed, if there is one.