Quality Assurance

3A Molecular Sieve
Manufactured by
Medaad, group manufacturer
Countries served
40+ worldwide
Forms
Beads and pellets
Documentation
3A Molecular Sieve for Drying Reactive and Polar Streams
SorbiTech Group 3A molecular sieve is a Type A zeolite with an even pore of about 3 Å, the narrowest opening in the molecular sieve range. It is the grade for streams where the product is small, polar or reactive and only the water has to come out.
Ion exchange narrows each ring opening of the Type A crystal to its 3 Å size. A clay binder then holds the crystals together as beads or pellets. Firing drives out the water and hardens the binder, so the sieve leaves the plant ready to adsorb.
Available Mesh Sizes
| Mesh Size | Particle Diameter | Shapes |
|---|---|---|
| 8 x 12 mesh | 1.6 to 2.6 mm | Beads (spheres) Pellets (extrudates) |
| 4 x 8 mesh | 2.5 to 5.0 mm |
Why the 3 Å Opening Matters
Water is the only common molecule narrow enough to pass the 3 Å window. Methanol, ethanol and the light olefins are wider. They stay in the stream and leave the bed as product, so there is almost no coadsorption and the working capacity of the charge goes to water.
Ethylene, propylene and butadiene never reach the inside of the crystal. When the bed is heated they cannot polymerise in the pores, so no gum or coke builds up there. Argon and krypton are also too wide, which keeps the gas fill of a sealed glazing unit in place.
3A in Cracked Gas and Ethanol Dryers
A fuel ethanol dryer takes the alcohol from the 95.6 percent azeotrope up to fuel grade. The 3A bed often runs liquid full there. The larger 4 x 8 particle keeps the pressure drop down through a deep bed. Flow runs downward, so the beads stay settled and do not grind against each other.
A cracked gas dryer works in the gas phase and usually takes 8 x 12. The smaller particle packs evenly and keeps the zone where water is being taken up short.
Regeneration Limits for 3A
3A gives up its water at a fairly low temperature. The purge, dry product gas or a dry inert gas, typically enters at 200 to 230 °C and flows against the drying direction. The safe maximum for the sieve is about 325 °C. A bed cleared this way typically dries gas to a water dew point below minus 100 °C.
Raise the heat slowly, then cool the vessel before it returns to service. These figures are typical for this kind of grade. They are not published product values.
Why Choose SorbiTech Group
Worldwide Supply
In Stock, Fast Delivery
Technical Support
Supply and Engineering Support for 3A
SorbiTech Group supplies 3A molecular sieve to olefin and cracked gas plants, fuel ethanol producers, insulating glass makers and refrigerant users. Orders range from the first fill of a new dryer to the recharge of a unit already running.
Our application engineers choose the grade, particle size and bed arrangement from your stream data. That covers the stream composition, including any olefins or alcohol, the flow, pressure and temperature, the water at the inlet and the dryness you need. When a project needs more than the media, the group also designs and supplies the adsorber vessels and complete drying units.
Share your operating data with us for a 3A selection and a quotation for your unit.
Where 3A Molecular Sieve Is Used
How is 3A kept dry between delivery and loading?
In its sealed packs, indoors or under a waterproof cover, on pallets off the ground. Big bags suit only a few weeks outdoors. Open sieve takes up water from the air quickly, so an opened drum is used within the shift or resealed.
Why must liquid water be kept off a hot 3A bed?
Liquid water on hot beads attacks the crystal and the clay binder. The beads crack from the thermal shock and the binder softens, so a section of the bed can turn to fines in one event.
Is 3A hazardous to handle?
It is chemically close to clay and does not burn. Dust irritates the eyes, skin and airways, so goggles, gloves and a dust mask are normal during loading. Freshly activated sieve heats up sharply when wetted.
Is some dust from a new 3A charge normal?
A small amount is. The first dry gas purge carries loading fines to the outlet filters. If the filter pressure drop levels off after the first weeks, the dust came from the new charge.
Can the 3A TDS and SDS be seen before ordering?
Yes. Both are sent on request through the TDS request form. The specification for an order, with its limits and test methods, is agreed at the quotation stage.
What is done with spent 3A?
Disposal follows local regulations. The zeolite itself is close to ordinary clay, so the residues it held in service decide how it is classed. A laboratory analysis of a sample usually settles that.