Molecular SieveZeolite AdsorbentsBy SorbiTech™

Molecular Sieve Engineering Guides

Five guides, each on one design decision for a molecular sieve dryer or adsorber, with typical ranges and units.

Related Solutions

Quick Answer

Molecular sieve engineering guides cover grade selection, dryer bed layout, regeneration, replacement and the causes of shortened bed life. Each guide takes one design decision on 3A, 4A, 5A or 13X and gives typical ranges with units, such as a regeneration purge of 200 to 315 °C at the vessel inlet.

  • Grades 3A, 4A, 5A and 13X
  • ASTM D4179 crush strength
  • ASTM D4164 tapped density
  • Manufactured by Medaad

Request the TDS Request the SDS

The guides are written for engineers who design, operate or buy adsorption units. Each one takes a single decision and sets out the principle, the typical ranges where the literature supports them, and the points that change from plant to plant.

Values in the guides are typical and published for guidance only.

Engineering Guides by Design Question

Each guide answers one question. Read them in order for a new unit, or open the one that matches a problem on a running plant.

GuideThe question it answers
Types and grade selectionWhich of the four grades a stream needs, starting from the molecule that must stay out
Dehydration bed designHow a dryer bed is laid out and sized in principle, zone by zone
Regeneration temperature and cycleThe typical purge temperatures by grade and duty, and the shape of one thermal swing cycle
Loading and replacementWhen a charge is due and how a change out is carried out
Service life and dustingWhat shortens bed life, where dust comes from and how drums are stored

Related Duty and Grade Pages

The guides explain method. The process duty pages apply it to one separation, such as gas dehydration or ethanol drying, and the grade pages carry the data for 3A, 4A, 5A and 13X.

The media in these guides is made by Medaad, and the vessels and units by PuraSpecs. Send a question about one plant through the enquiry form, with the feed analysis and the operating case.

Questions on the Engineering Guides

Which guide comes first for a new dryer?

Types and grade selection, then dehydration bed design, then regeneration temperature and cycle. Loading and replacement and service life follow once the unit is running.

Which guide helps when a running bed is losing capacity?

Service life and dusting lists the causes and their symptoms. Loading and replacement covers the signs that a charge is spent and how a change out is run.

Are US customary units given as well as SI units?

For the main design figures, yes. Bed design gives values such as a minimum bed depth of about 1.8 m (6 ft), and regeneration gives purge temperatures in both degrees Celsius and Fahrenheit.

Do the guides apply to liquid phase duties?

In part. Grade selection, regeneration and loading apply to liquid duties too, but liquid beds follow their own velocity rules and often flow upward during adsorption, as in LPG and NGL treating.

Can the guides be used for a design review?

They give method and typical ranges for guidance. A design review for one plant needs its feed analysis, operating case and bed history, sent through the enquiry form.

Ask About a Dryer or Adsorber

Send the feed analysis, the outlet target, the bed history and the regeneration conditions. Say whether the question is a new design, a change of grade or a problem on a running bed.

Request a Quote
Contact
Email[email protected] Call+971 56 777 3027