Catalyst Protection Through Petrochemical Olefin Purification
Cracked gas dryers, product dryers and guard beds between the steam cracker and the polymer reactor.
Quick Answer
Petrochemical olefin purification is the drying and guard bed treatment that protects polymer catalysts from water and oxygenates. A 3A dryer takes water from cracked gas after compression while ethylene, at 3.9 Å, stays out of its 3 Å pore. 13X guard beds remove methanol, MTBE and dimethyl ether from olefin and C4 feeds.
- Zeolite 3A and 13X
- Media made by Medaad
- Crush strength to ASTM D4179
- Tapped density to ASTM D4164
- Attrition to ASTM D4058
A steam cracker turns naphtha or ethane into ethylene, propylene and a C4 cut. Most of that output feeds a polymer unit. The polymerisation catalyst there reacts to traces that the cracker itself tolerates. Water, oxygenates, sulfur species and carbon oxides lower its activity, and some stop it outright.
Molecular sieve for petrochemicals is used in a large dryer and in smaller polishing beds. The large dryer protects the cold section of the cracker from ice and hydrate. Dryers and guard beds downstream then polish each product before it reaches the reactor.
Cracked gas and olefin dryers run on 3A, and oxygenate guard beds on 13X.
Cracked Gas Dryers and Olefin Guard Bed Units
SorbiTech Group builds the dryer units that carry the sieve in an olefin plant. The twin tower TSA dehydration unit suits the cracked gas dryer and the product dryers. The cycle and the equipment around the beds are described under dehydration units. Hydrogen for the reactor can be cleaned in the hydrogen PSA purification package. Vessels and skids come from PuraSpecs, the group's equipment company.
Polymerisation Catalyst Poisons and Their Sources
A polymer catalyst licence names the traces its reactor tolerates, usually water, oxygenates, carbon oxides and sulfur species. Each comes from a different source and has its own bed.
| Contaminant | Where it comes from | Where it is taken out | Duty |
|---|---|---|---|
| Water | Quench water, dilution steam and the caustic wash | Cracked gas dryer after compression, then product dryers after fractionation | Cracked gas and olefin drying |
| Oxygenates such as methanol, ethers and dimethyl ether | The ether unit on the C4 raffinate, and methanol dosed against hydrates | Guard beds at the polymer unit boundary and on the C4 raffinate | Oxygenate removal |
| Carbon dioxide | Formed in the cracking furnaces and carried in the feed | Caustic wash for the bulk, then ethylene and propylene guard beds for traces | Product guard beds |
| Sulfur species such as hydrogen sulfide, carbonyl sulfide and mercaptans | Sulfur in the cracker feed and in the agent dosed to limit furnace coking | Caustic wash for hydrogen sulfide, then propylene guard beds for carbonyl sulfide | Propylene guard beds |
| Carbon monoxide | The cracking furnaces, leaving the cold box with the hydrogen | Hydrogen cleanup before the polymer reactor and the hydrogenation units | Hydrogen purification |
| Water in recycled diluent | The reactor section and polymer finishing | Dryers on the diluent and solvent recycle loop | Solvent drying |
Cracked Gas Dryer Ahead of the Cold Box
The cracked gas dryer sits after the final compression stage and the caustic tower. At that point the gas is at full pressure and has been cooled. It therefore carries less water than anywhere else in the train, which limits the size of the bed. A coalescer in front of the dryer keeps caustic carryover and liquid water off the bed. Both would damage the adsorbent and shorten its working life. Propylene, at 4.5 Å, is also too wide for the 3A pore. The purge on these dryers is kept cool, typically 200 to 230 °C.
Behind the dryer, the chilling train and demethaniser run colder than any other point in the plant. Ice or hydrate there narrows the exchanger passages and raises pressure drop. The usual remedy is a warm up of the cold box, which takes the cracker off its normal rate. Water that passes this dryer also travels on with every product. The product dryers downstream then carry a load they were not sized for.
Gas runs left to right along the top row and continues along the bottom row. Blue boxes mark the adsorption steps.
Polymer Grade Olefin Feed and C4 Stream Treating
After fractionation the bulk water is gone. The beds now polish each stream to the catalyst licence limits. Ethylene and propylene leave the splitters as products but are not yet reactor feed. The C4 cut follows a separate route through butadiene extraction. Each route brings its own traces, so each needs its own bed.
Polymer Grade Ethylene and Propylene
The polymer unit sets the impurity limits. Product dryers on ethylene and propylene take the trace water that fractionation leaves behind. The guard beds at the reactor boundary then hold whatever slipped through upstream. Activated alumina from Medaad often shares these vessels with the zeolite, each layer taking different traces. Hydrogen fed to the reactor for molecular weight control is held to the same standard.
C4 Streams After Butadiene Extraction
The raffinate left after butadiene extraction often passes an ether unit, where methanol reacts with isobutene. Unreacted methanol, the ether and dimethyl ether travel on with the butenes. A liquid phase guard bed on the raffinate holds them before the butenes go to comonomer, metathesis or alkylation. Straight chain paraffins for linear alkylbenzene feedstock come from kerosene instead, through a separate shape selective separation.
Related Olefin Plant Guides
The heating step for olefin beds is set out in regeneration temperature and cycle, and vessel internals in adsorber vessel design. Refinery streams that feed the same plants are covered under oil refineries. The 3A grade page lists sizes and forms for the dryer charge.
Questions on Olefin Purification Beds
Why do cracker dryers use 3A and not 4A?
Ethylene and propylene are small enough to enter a 4A window. An olefin inside the cage sits against acid sites, reacts with the next olefin to arrive, and the bed starts to foul.
What is green oil in an olefin dryer?
Two olefins joined inside the pore make a heavier molecule too large to leave. More joins build green oil, which coats the bead from inside and bakes into coke when the bed is heated.
Why is the olefin swept out before a dryer is heated?
Any olefin left in the bed reacts faster as it gets hotter. Usual practice is to sweep the vessel first, then heat at a lower temperature held for longer.
Why do oxygenates harm the acid catalysts after a C4 guard bed?
An oxygenate neutralises acid sites directly, and part of the lost activity never comes back. That is why the guard bed sits in front of the reactor.
When are cracker dryers usually recharged?
At turnaround, so most enquiries are for a replacement charge in an existing vessel. The regeneration conditions usually decide how long a charge lasts, so they are checked at the same time.
Quote for Olefin Dryers and Guard Beds
SorbiTech supplies Medaad media for cracked gas dryers, product dryers and polymer feed guard beds. The group also offers a twin tower thermal swing dryer. Send the stream and its full analysis, including oxygenates and sulfur species. Add the licence limits, the existing vessel and the regeneration gas available.