Molecular SieveZeolite AdsorbentsBy SorbiTech™
Horizontal process vessel at a renewable fuels plant

SAF and Renewable Diesel Drying With Molecular Sieve

Molecular sieve takes the water made in hydrotreating out of the stream before the isomerisation reactor.

Find My Solution

Quick Answer

SAF and renewable diesel drying removes the water made when fats and oils are hydrotreated, using a 4A molecular sieve bed ahead of the isomerisation or dewaxing catalyst. That catalyst loses activity when water reaches it. A 13X layer is added where light oxygenates survive deoxygenation and must come out too.

  • 4A and 13X molecular sieve
  • Beads and pellets
  • 8 x 12 and 4 x 8 mesh
  • Tapped density by ASTM D4164
  • Particle size by ASTM D4513
  • Manufactured by Medaad

Request the TDS Request the SDS

Updated

Why Sustainable Aviation Fuel Units Make Water

A fat or a vegetable oil is a hydrocarbon with oxygen attached. Turning it into jet fuel or diesel means taking that oxygen off, and in a hydrotreater it leaves mostly as water.

This is bulk water. A stream that began as a triglyceride carries far more water after deoxygenation than a fossil feed would, and all of it must come out before the next stage.

Water and the Isomerisation Catalyst

Product from the hydrotreater is waxy and fails jet fuel cold flow limits. It goes to an isomerisation or dewaxing reactor to fix that, and water harms that catalyst.

Water suppresses the acid function these catalysts depend on. Activity falls, the operator raises the temperature to compensate, and the higher temperature shortens catalyst life.

Figure 01 · Where the water appears on a HEFA route
FEEDSTOCKfat or oilOXYGEN BOUND INHYDROTREATERoxygen strippedWATER MADE HEREDRYER4A bedWATER OUTISOMERISERcold flowNEEDS IT DRYThe water is made inside the process.

Figure 01 · One route in outline. Gasification and alcohol to jet routes reach the same fuel by a different path and put the drying step elsewhere.

SpeciesWhere it comes fromEffect downstream
Waterdeoxygenationsuppresses the acid function
Light oxygenatesincomplete conversionneeds a high capacity layer
Phosphorusthe feedstockremoved in feed pretreatment
Chlorideswaste feedsremoved on a guard bed

Sizing for a Changing Feedstock Slate

A refinery crude slate changes slowly. A renewable plant may run used cooking oil one month, tallow the next and a vegetable oil after that, depending on what can be bought.

Each carries a different oxygen content and makes a different amount of water. A bed sized for the mildest feedstock is too small as soon as the plant buys one with more oxygen.

FeedstockRelative oxygenWater made
Vegetable oilhighmost
Used cooking oilhigh, variablemost, and it moves
Tallow and animal fathighmost
Fossil co feednegligiblelittle

Phosphorus, Metals and Chlorides

Renewable feedstocks carry more contaminants than fossil ones. Phosphorus from residual phospholipid, alkali metals and the chlorides in waste feeds are not removed by the molecular sieve.

They are taken out in feed pretreatment and on guard beds ahead of the hydrotreater. SorbiTech supplies that guard media separately.

Light Oxygenates After Deoxygenation

Deoxygenation is not always complete, and some light oxygenates survive it. Taking them out is closer to oxygenate removal than to drying, and needs a wide pore with high capacity.

Where water and oxygenates are both present, the bed is layered.

Layer Selection by Stream Content

PuraDry 4A carries the drying duty. 13X APG, a 13X grade, forms the oxygenate layer where one is needed. Both come as beads and as pellets.

Stream after the hydrotreaterBedLayer order
Water only4A, single layernone to set
Water and light oxygenates4A and 13X APGset by the route
Feedstock slate that movessized for the worst feedas above

Which layer goes first depends on the route and on which species the next stage tolerates least. The bed is cleared with a dry purge, typically at 200 to 315 °C at the vessel inlet, and kept below about 325 °C so the crystal is not damaged. Grade selection gives the sizing method.

Dryer Vessels for New and Running Plants

Most renewable units are new build. Bed sizing and layer order can be settled even after the vessels are contracted. For a new dryer, SorbiTech Group supplies the twin tower TSA dehydration unit, and the dehydration units page shows how the layered bed and the vessel are sized together.

On a running plant, recheck the bed against the feedstocks being bought now.

Request a Quote

Related Renewable Fuel Duties

Questions on Renewable Fuel Dryers

Can activated alumina share the vessel with the 4A?

Yes. On a wet stream, activated alumina on top takes the bulk of the water and the 4A underneath takes the stream down to the dryness the catalyst needs. The sieve carries a lighter load and needs less heat to clear. SorbiTech Group supplies both media.

What protects the bed from free water out of the separator?

A separator or coalescer ahead of the dryer. Liquid water that reaches beads which are already hot damages them on contact, and for the same reason the heat is brought up steadily during regeneration.

Where does the water taken off the bed go?

The hot purge leaves the vessel carrying it. The purge is cooled, the water drops out in a separator, and the dried purge gas is sent back for reuse.

Why does outlet moisture rise suddenly at the end of a run?

Water loads at the inlet first and moves down the bed as a front, with dry sieve still ahead of it. The outlet stays dry until the front reaches the bottom, then climbs quickly. The towers are switched before the front arrives.

Why does the regeneration purge run against the drying flow?

The hot purge enters at the outlet end and leaves by the inlet, so the water leaves by the face where it came in. The end that delivers product stays the driest part of the bed, and the bed is cooled to line temperature before it goes back on line.

Quote for a Renewable Fuels Dryer

Send the process route, the full feedstock slate and any stream analysis you have.

Request a Quote
Contact
Email[email protected] Call+971 56 777 3027