Keeping the Cold Box Clear With Molecular Sieve for LNG Plants
Layered dryer beds that protect the main cryogenic exchanger from ice, solid carbon dioxide and sulfur.
Quick Answer
Molecular sieve for LNG plants is the zeolite adsorbent that dries feed gas and removes trace carbon dioxide and mercaptans after the amine unit, before liquefaction. A layered dryer of 4A and 13X holds water below 0.1 ppmv and the carbon dioxide left by the amine unit below about 50 ppmv.
- Zeolite 4A and 13X
- Media made by Medaad
- Crush strength to ASTM D4179
- Attrition to ASTM D4058
- Tapped density to ASTM D4164
Every treating step in an LNG plant is there to protect the cold box. The molecular sieve dryer is the last of them. It takes water down to the level the main cryogenic exchanger tolerates. It also takes out the trace carbon dioxide left by the amine unit, and mercaptans where present.
A mercury guard sits near the plant inlet, and a heavy ends removal step may follow the dryer. The dryer sits between the acid gas unit and liquefaction, so its design depends on both.
Pretreatment Packages Ahead of Liquefaction
SorbiTech Group builds the pretreatment units that carry the sieve on an LNG train. On a baseload train the gas sweetening unit takes out the bulk acid gas first. The twin tower TSA dehydration unit then dries the sweet gas. A plant fed with pipeline gas may need only the dryer, as drawn below. Vessels and skids come from PuraSpecs, the group's equipment company.
Cold Box Inlet Limits for LNG Feed Gas
Liquefaction cools the gas until methane condenses at about minus 160 °C. Water, carbon dioxide and heavy aromatics freeze well before that point. The main cryogenic exchanger has narrow brazed aluminium passages. A small solid deposit there restricts flow through the whole train. Clearing it means stopping production and warming the cold box. Freeze out protection is therefore the first design basis of any pretreatment train.
The liquefaction licensor sets an inlet limit for each species, and every treating step is designed to those limits. Mercury and mercaptans do not freeze, but each has a limit too. Mercury attacks the brazed aluminium itself. Mercaptans pass through to the LNG and condensate products and leave them off specification.
Feed Gas Conditioning, Species by Species
The sieve removes some species itself and shares the rest with the units around it.
| Species | Where it is taken out | Why the cold box needs it out |
|---|---|---|
| Water | Sieve dryer after the amine unit, the last bulk treating step | Ice and hydrate block exchanger passages. The LNG pretreatment dryer removes it, even from gas already dried under natural gas dehydration. |
| Carbon dioxide | Amine unit for the bulk, sieve bed for the trace left behind | It deposits as a solid on exchanger walls. Carbon dioxide polishing runs on the dryer bed or on a bed of its own. |
| Mercaptans | Dryer vessel, in a layer of their own | They carry no freeze risk but report to the LNG and condensate. See mercaptan removal. |
| Heavy aromatics | Partly on the dryer bed, the rest in a heavy ends removal step | Benzene and heavier ends wax out in the coldest sections, as set out under layered dryer design. |
| Mercury | Separate non zeolite guard bed near the plant inlet | It attacks brazed aluminium exchangers. The guard is specified separately from the dryer. |
Baseload, Small Scale and Peak Shaving LNG
Pretreatment follows the same order in every plant, but scale changes what reaches the sieve. A baseload train starts from raw field gas. A small scale or peak shaving plant usually starts from pipeline gas that is already treated. That sets the number of beds, the species they carry and the route for the regeneration gas.
Large Baseload Trains
A baseload train receives raw field gas. An amine unit removes the bulk of the carbon dioxide and hydrogen sulfide first. The sieve dryer follows and works on water saturated sweet gas. A mercaptan layer is added where the feed calls for it. Several vessels cycle in parallel, so one is always regenerating. The pretreatment dryer is designed to the licensor's inlet limits.
Each vessel is heated in turn with a slipstream of dry gas. That gas leaves carrying the water, carbon dioxide and mercaptans the bed released. A cooler and separator knock out the water. The rest returns to the plant inlet or goes to fuel. Mercaptans sent back to the inlet can build up in a loop. Plants with sulfur rich feed send the regeneration gas to its own treating step.
Small Scale and Peak Shaving Plants
Peak shaving plants liquefy pipeline gas in periods of low demand and store it. Small scale plants serve trucked and remote supply. Their feed is already sweet and dry to pipeline terms, and many have no amine unit. One sieve bed then removes water and carbon dioxide together. Odorant in distribution gas meets the same bed, so its type belongs in the enquiry. The regeneration gas route is fixed together with the bed design.
The Treating Train From Inlet to Liquefaction
Gas flows left to right. The blue box is the sieve step. The dashed line is spent regeneration gas.
Related LNG Duties and Guides
Layer depths and vessel sizing are set out in dehydration bed design. Feed that is still sour at the dryer is covered under sour gas dehydration. The gas plant upstream of liquefaction is described under oil and gas processing, and the 13X grade page lists sizes and forms.
Questions on Molecular Sieve for LNG Plants
What does the guard layer at the top of an LNG dryer do?
A layer of activated alumina or silica gel takes most of the water at low cost. It also shields the sieve from a liquid slug carried over from the amine unit.
Why does the 13X layer sit above the 4A in an LNG dryer?
The wide 13X pore takes the mercaptans and heavier hydrocarbons, which are too large for 4A. The 4A layer at the bottom then takes the last of the water.
How many dryer vessels does an LNG train usually run?
Usually three or four, often two drying and one regenerating, because the vessels are large and regeneration takes hours. Each vessel typically adsorbs for about 16 hours.
How hot is the regeneration gas on an LNG dryer?
A slipstream of dry gas, about a tenth of the feed, enters at 250 to 300 °C. The crystal degrades if the bed is held above about 325 °C.
Why is the heating ramp on an LNG dryer kept slow?
A fast ramp boils water off the top layers and condenses it on the cooler bed below. That leaches the binder and weakens the beads.
Quote for an LNG Dryer Charge
SorbiTech supplies the adsorbent charge for an existing dryer. The group also offers a complete twin tower TSA dehydration unit. For a quote, send the feed gas analysis with carbon dioxide, mercaptans and aromatics, the train capacity and the licensor's inlet limits. State the number of dryer vessels and the regeneration gas route.