Molecular Sieve Packaged and Static Desiccant
Molecular sieve sachets, canisters and inserts keep sealed packs of drugs and electronics very dry.
Quick Answer
Static desiccant in molecular sieve takes up the moisture sealed into packs of drugs, diagnostics and electronics and holds humidity very low. A 4A fill is still pulling water at 10 percent relative humidity, which suits a pack that must end dry, and 3A is used where a volatile in the pack has to stay out of the pore.
- PuraDry 4A and 3A
- Beads and powder
- Attrition by ASTM D4058
- Particle size by ASTM D4513
- Manufactured by Medaad
Updated
Moisture Sealed in With the Product
Sealing a pack does not make it dry. Air goes in with the product, the packaging materials carry their own moisture, and most barrier films let a little water through over months on a shelf.
For a tablet, a diagnostic strip, an electronic assembly or a steel part in transit, that is enough to cause damage. A desiccant packed with the product takes the water up.
Zeolite and Silica Gel Across the Humidity Range
Each desiccant is strongest in a different part of the humidity range, and that decides the choice.
Silica gel takes up a great deal of water when the air is humid, which suits a pack that starts wet. A zeolite takes up less at high humidity but holds on far harder at low humidity, so it keeps pulling moisture down after a gel has come into balance. SorbiTech supplies both. The choice depends on how dry the pack must end up.
Figure 01 · Where each material is strongest, drawn without a capacity scale. Isotherms differ between grades and with temperature.
| Molecular sieve | Silica gel | |
|---|---|---|
| Strongest | at low humidity | at high humidity |
| Holds at 10 percent RH | still pulling | largely in balance |
| Capacity at 80 percent RH | lower | higher |
| Suits | a pack that must end dry | a pack that starts wet |
Sizing a Fill for the Shelf Life
The fill goes in at packing and leaves with the waste. No one checks it in between.
So it is sized for the whole shelf life at once: the moisture already in the pack, plus what the barrier lets through over the months it must last, plus a margin in case the pack is stored somewhere warmer than planned.
Sachets and Canisters for Drug and Electronics Packs
The product decides the format. A sachet is the cheapest and goes loose in the pack, unlike an insulating glass unit, where the fill is built into the structure. A canister stands up to a tablet bottle being shaken.
Moulded inserts and cards hold the desiccant in a set place, such as an instrument housing or a diagnostic cassette. The fill is the same. Only the enclosure changes.
| Format | Suits | Note |
|---|---|---|
| Sachet | loose in a pack | cheapest, can be punctured |
| Canister | tablet bottles | rigid, will not split |
| Moulded insert | instruments and cassettes | sits where it is needed |
| Compounded into plastic | closures and liners | supplied as powder |
Dust Control in Drug and Electronic Packs
The desiccant shares a sealed space with a product that will be swallowed, implanted or soldered, so dust matters.
The bead needs low attrition so little dust forms, and the sachet material or canister cap must hold back what does form. For a regulated product, the material of both is specified before the capacity.
Matching the Grade to the Pack
PuraDry 4A is the usual static grade. The table shows when another grade or form is specified.
| What the pack needs | Grade | Form |
|---|---|---|
| Must end very dry | PuraDry 4A | beads in a sachet or canister |
| Holds a volatile that must stay in the product | PuraDry 3A | beads |
| Desiccant built into a closure, liner or card | powder grade | powder for compounding |
The powder grade is listed in the product range.
Supply to Packaging Converters
SorbiTech supplies bead and powder grades to packaging converters, who buy to a production schedule. The converter fills the sachet or canister, and the drug or electronics maker packs it with the product.
Write the attrition loss and the residual water as packed into the order. The first bears on dust in the pack. The second shows how much capacity is left when the fill is sealed in. The quality and specification page lists the methods.
Related Desiccant Uses
- Pharmaceutical and medical desiccants, covering packs, devices and plant.
- Refrigerant drying, a fill sealed into a refrigeration circuit.
- Molecular sieve and silica gel compared, across the humidity range.
- Service life and dusting, on how beads make fines.
- Bulk 4A and powder supply and manufacturing detail from Medaad, the group manufacturer.
Questions on Packaged Desiccant Fills
How should bulk fill be handled on the packing line?
Keep drums and lined bags closed until the filler is ready. A fill starts taking up water the moment it meets room air, and every hour on an open line spends capacity meant for the pack.
Does a fresh fill give off heat?
Yes. Molecular sieve releases a large amount of heat as it takes up water. It is one more reason to keep bulk fill sealed until it is packed.
What humidity is a sealed equipment pack held to?
Export packing procedures for plant equipment commonly ask for enough desiccant to keep the air inside a sealed foil pack below 50 percent relative humidity for the whole storage period. The permeability of the packaging material is measured to BS 3177.
Does a sieve fill still work in a warm store?
Yes. Molecular sieve keeps its hold on water as the temperature rises. Drying practice for air warmer than about 40 °C turns to molecular sieve for that reason.
Do oxygen concentrators use the same sieve?
No. A concentrator bed holds nitrogen back from room air and is cleared by pressure thousands of times. The oxygen generation duty covers those beds.
Quote for a Packaging Desiccant
Send the pack volume, the barrier film, the shelf life required and where the pack will be stored.